Sec. 13-50. - Specifications.

(a) All streets and subsurface drainage in the city shall be constructed in accordance with the standard specifications outlined in this section. Permanent surface streets constructed in the City of Kenner shall be either Portland Cement concrete or asphaltic concrete in accordance with these specifications. Prior to roadway construction the developer will be required to submit contract drawings prepared by a Louisiana licensed engineer, for the director of public works review and approval. The contract drawings must show location, type, and dimensions of the prescribed work and must include layouts, profiles, cross sections and other details necessary for review and construction. Permanent street construction adjacent to drainage canals shall be constructed based upon the standard requirements for paving structures and the recommendations of a site-specific soils report which addresses slope stability. A copy of the soils report shall be given to the director of public works. (1) Portland Cement concrete streets shall be constructed with sand sub-base over which the concrete shall be placed. The concrete and joint specifications are as follows: a. Concrete shall have a minimum compressive strength of 4,000 PSI @ 28 days. b. The slump shall not exceed 5 inches. c. The pavement shall not be opened to traffic until 14 days after concrete has been placed unless the director of public works approves otherwise. d. Roadway thickness shall be designed at eight (8) inches, reinforced with 6 × 12-0/1 mesh. Acceptance requirements, however, shall be in accordance with the most recent edition of the Louisiana Standard Specifications for Roads and Bridges. e. Expansion joints shall be constructed in accordance with the latest edition of LDOTD Standard Plan CP-01 Portland Cement Concrete Pavement Details. f. Construction joints shall be constructed in accordance with the latest edition of LDOTD Standard Plan CP-01 Portland Cement Concrete Pavement Details. g. A longitudinal metal keyed joint shall be located at the street centerline. (2) Asphaltic concrete surface streets: Asphaltic concrete streets constructed in the City of Kenner shall meet the requirements of paragraphs (a)(2) through (m). Streets will be classified as either "residential" or "nonresidential" by the director of public works. a. Residential streets: 1. Base material shall be composed of 6½" crushed stone compacted to 98 percent of maximum dry density at optimum water content in accordance with ASTM D 1557. 2. Asphaltic concrete shall be 1½" Type 1 wearing course, 2½" Type 1 binder course. 3. Subbase thickness specified in paragraph (f) may be 12 inches. b. Nonresidential streets: 1. Base material shall be composed of 6" thick crushed stone compacted to 98 percent of maximum dry density at optimum water content in accordance with ASTM D 1557. 2. Asphaltic concrete shall be 1½" Type 1 wearing course, 2½" Type 1 binder course and 4" Type 5A base course. The following paragraphs shall apply to all surface streets constructed in the City of Kenner. (b) Materials and construction specifications shall meet the minimum requirements of the latest edition and revisions of the Louisiana Standard Specifications for Roads and Bridges, published by the State of Louisiana, Department of Transportation and Development, Office of Highways, except as modified by this section. (c) Site preparation: The site shall be adequately drained to prevent the accumulation of water and shall be maintained during the entire course of construction. (d) Subgrade preparation: The existing ground surface beneath new pavement areas shall be stripped of all vegetation, trees, stumps, loose topsoil, debris and any other deleterious materials. Any weak areas, stump holes, ditches and/or depressions within these areas shall be thoroughly cleaned out to the surface of firm undisturbed soil and backfilled with a select fill material as defined by DOTD designation: TR 423 Classes A-1-a, A-1-b, A-3, A-2-4, A-2-6, A-4 or A-6 having a maximum liquid limit of 35 and a maximum Plasticity Index of 15. (e) Geotextile fabric: Woven geotextile fabric with the following minimum properties shall be placed on the subgrade without folds or wrinkles and in accordance with manufacturers' recommendations: Fabric Property | Test Method | Minimum Specifications Apparent Opening Size | ASTM D4751-87 (U.S. Standard Sieve Size) | 100<eos<30 Puncture Resistance | ASTM D4833 | 115 lbs Mullen Burst | ASTM D3786 | 600 psi Trapezoid Tear Strength | ASTM D4533-85 | 110 lbs Grab Tensile/Elongation | ASTM D4632-86 | 280 lbs/15% UV Resistance | ASTM D4355-84 (% required after 500 hours) | 70% Laps shall be as recommended by the manufacturer but in no case shall be less than 24". (f) Subbase shall be structural fill locally available, hydraulically dredged river sand. Materials shall be non-plastic, free of roots, clay lumps and any other deleterious materials with no more than 10 percent weight passing a U.S. Standard No. 200 sieve. The subbase sand should be placed in thin lifts (not exceeding 12 inches loose thickness) and each lift compacted to at least 98 percent of maximum dry density at optimum water content in accordance with ASTM D 1557 (95 percent for the bottom layer). The subbase thickness shall be a minimum of 24 inches for concrete streets and 20 inches for asphaltic concrete streets. (g) Curbs: Barrier or rollover concrete curbs shall be constructed for Portland Cement concrete or asphaltic concrete streets and shall be in accordance with the plans approved by the City of Kenner. (h) Drainage: The following drainage requirements shall be met: (1) Inlet spacing shall be in accordance with Louisiana Department of Transportation and Development Hydraulics Manual, latest edition, and shall be approved by the director of public works. Inlets shall be installed at a maximum spacing of 200 feet on center. (2) One 12-inch diameter, P.V.C. pipe shall be installed on the opposite side of street from main storm drainage line using the same slope as the main line and shall be connected into the drain inlets. (3) The drain pipe under the street shall be placed on a foundation consisting of two 2 × 12 boards parallel with the pipe and one 2 × 12 board spaced at 2 feet on center perpendicular to the pipe with 12 inch minimum crushed stone base. (4) The size and type of the drainage pipe and drain inlets shall be as per the latest editions of the Jefferson Parish Drainage Design Manual and the Louisiana Department of Transportation and Development Hydraulics Manual and shall be approved by the director of public works. (i) Right-of-way width, grade and elevations: (1) The minimum right-of-way for 26-foot two lane street shall be 50 feet. (2) The minimum right-of-way for a 4-lane street with a 24-foot median shall be 100-feet. (3) The minimum grade at the street center line shall be 0.3%. (4) The minimum street elevation at the crown shall be 18 inches below the flood elevation established by the Federal Emergency Management Agency (FEMA) on its Flood Insurance Rate Map (FIRM). A variance for lower street elevations may be permitted by the director of public works where existing developed areas dictate a lower minimum street elevation. (j) Traffic signs, street signs and striping shall be designed and constructed in accordance with Kenner ordinances and the Louisiana Manual of Uniform Traffic Control Devices published by the Louisiana Department of Transportation and Development. All traffic signs and striping shall be provided by the developer and shall be in place prior to opening of the street. Signing and striping plans shall be reviewed and approved by the director of public works prior to street construction. (k) Surcharge: A major portion of the City of Kenner consists of drained wetlands in which soil subsidence is a major characteristic. In order to minimize post-construction settlements of roadways constructed in drained wetlands, the city will require a preload-surcharge program. The director of public works will determine in what areas of Kenner a preload-surcharge program is required based on existing soil survey data and site specific conditions. The objective of the preload-surcharge is to achieve 90 percent of the primary consolidation of the swamp marsh deposits. The preload-surcharge program will be based on a subsoil investigation report prepared by a geotechnical engineer approved by the director of public works. For projects with streets totaling less than five hundred (500) linear feet, the developer has the option of placing, for a period of six (6) months, a surcharge equivalent to two (2) times the final roadway section which shall include the initial fill, subbase, base and surface material. (l) Notice-to-proceed: Before starting construction, the developer must receive written notice from the department of public works stating that the city is satisfied that the project plans and specifications conform to the City of Kenner Code of Ordinances and the developer has met all of the city's preliminary requirements. (m) Acceptance of roadway: Permanent roadways constructed with Portland Cement concrete or asphaltic concrete surface shall be accepted by the City of Kenner for maintenance upon completion. The condition of acceptance for maintenance will be based on the following requirements: (1) Testing laboratory: Testing and inspection required by these specifications and the latest edition and revisions of the Louisiana Standard Specifications for Roads and Bridges shall be performed by testing laboratories acceptable to the city and developer and the costs thereof shall be borne by the developer. (2) Testing procedures: a. Subbase: Subbase depth shall be checked at 1 point every 100 feet of roadway. Underthickness tolerance will be limited to minus 0.10 feet (1¼"). b. Concrete and asphalt tests shall be in accordance with the latest edition and revisions of the Louisiana Standard Specifications for Roads and Bridges. c. Concrete thickness shall be checked by coring at 1 point as selected by the city inspector every 100 feet. Concrete not meeting the thickness requirements shall be removed. d. Concrete test cylinders: Four (4) cylinders shall be required for each day's pour or each 100 cubic yards of concrete placed. If the tests indicate a cylinder compressive strength of less than 4000 psi, concrete cores shall be taken from where the cylinder was made and tested. If the core strength is less than 4,000 psi, the panel shall be removed and replaced. The panels which are adjacent to the removed panel shall be cored and the same procedure followed until strength requirements are met. (3) As-built Drawings: The developer shall furnish as-built drawings of the roadway and associated work on a reproducible film. The as-builts, prepared by the street construction contractor, shall include elevations and utility inverts determined by a Louisiana licensed surveyor and shall be reviewed by the developer's engineer. (4) Resident inspection: Prior to issuance of the notice-to-proceed, the developer shall deposit with the city a check for inspection fees. The amount of deposit will be 2.2% of the mutually agreed upon construction cost of the items to be inspected as specified on the plans and specifications approved by the city council. The items of work to be included in the construction cost are those pertaining to surcharge, sidewalks, roadways, drainage, sewerage, lighting and fire safety. The 2.2% fee does not include testing laboratory costs and survey verification which will be paid directly by the developer. The deposit will be adjusted to include major changes in the work prior to the city accepting the streets for maintenance. (n) Temporary roads constructed on unimproved streets or driveways shall meet the following requirements: (1) A permit shall be obtained from the department of public works. The permit shall be for a two-year period which may be renewed upon reapplication. (2) The permit fee will be $100.00 for every 300 linear feet of roadway or portion thereof. (3) The roads shall be maintained by permittee throughout the permit period. Failure to maintain the roadway may result in revocation of the permit. (4) No building permit shall be issued for a lot fronting the temporary road. (5) Temporary roads shall be equipped with proper traffic signs as approved by the director of public works. (6) Traffic will be permitted only on approval from the director of public works. (7) Temporary roads shall be constructed of 2½" asphaltic concrete on an 8½" base course. (8) Drainage: Grassed swales with approved erosion control measures shall be constructed to drain the road. (9) Elevation shall be as per the provisions of paragraph (i) of this section. (10) Temporary roadway width shall be a minimum of 22' with 3' shoulders on both sides of the road (28' total width). (11) Temporary roadway cross slope shall be 0.025 foot per foot for the roadway and shoulders. Side slopes shall be 2' horizontal to 1' vertical, maximum. (o) Utilities: All public and private utilities including cable television, telephone and electrical services shall be installed in accordance with Chapter 50, electrical rules and regulations as outlined in the building code of the City of Kenner, unless superseded by other city ordinances or electrical code standards as set by the National Electrical Code and/or the governing authority of the City of Kenner with the exception that the wording "or rear line overhead" shall be omitted. A variance may be permitted by the director of public works where existing overhead utilities are present. (1) Street lights shall be constructed in accordance with the provisions of the National Electrical Code, the electrical rules and regulations of the building code of the City of Kenner and the following specific requirements for residential streets: a. Street light fixtures shall be Carouse Hinds RMA15-SN4-22-L5, 150 watt, HPS, 240 volt 5% with Fisher Pierce Series 6660 photo cell, or approved equal. b. Street light standards shall be eighteen foot (18') P&K tapered spun aluminum street light standard with six foot (6') arm and twenty foot (20') mounting height, or approved equal. c. All wiring and foundations shall be in accordance with Chapter 50, electrical rules and regulations as outlined in the building code of the City of Kenner, unless superseded by other city ordinances or electrical code standards as set by the National Electrical Code and/or the governing authority of the City of Kenner. Any variance to the aforesaid paragraph may only be allowed with the approval of the chief of the office of inspections and code enforcement.

(Ord. No. 6493, § 2, 9-20-90; Ord. No. 6992, §§ 1, 2, 3-17-94; Ord. No. 7146, § 1, 1-5-95)

Ask a question about Kenner law

Corpus searches the Kenner sections it holds and shows the ones that match, with their citations. Free, no sign-in.