Sec. 34-67. - Specific standards.

In all areas of special flood hazard where base flood elevation data have been provided as set forth in section 34-30 or 34-49, the following standards are required: (1) New construction and substantial improvement of any structure with fully enclosed areas below the lowest floor that are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria: a. A minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided. b. The bottoms of all openings shall be no higher than one foot above the lowest adjacent grade. c. Openings may be equipped with screens, louvers, valves or other coverings or devices provided that they permit the automatic entry and exit of floodwaters. (2) New construction and substantial improvement of any residential structure shall have the lowest habitable floor including equipment or mechanical items elevated to a minimum of one foot above the base flood elevation. (3) New construction and substantial improvement of any commercial, industrial or other nonresidential structure shall either have the lowest floor including equipment or mechanical items elevated to a minimum of one foot above the base flood elevation; or, together with attendant utility and sanitary facilities, shall: a. Be floodproof so that below the required flood protection level the structure is watertight with walls substantially impermeable to the passage of water; b. Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; and c. Be certified by a registered professional engineer or architect that the standards of this subsection (3) are satisfied. Such certifications shall be provided to the official as set forth in section 34-50(2). (4) All manufactured homes shall be placed in accordance with section 34-66 and according to the following requirements: a. All manufactured homes to be placed within Zone A on a community's FIRM shall be installed using methods and practices which minimize flood damage. For the purposes of this requirement, manufactured homes must be elevated and anchored to resist flotation, collapse, or lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This requirement is in addition to applicable state and local anchoring requirements for resisting wind forces. b. All manufactured homes that are placed or substantially improved within Zone AE on the community's FIRM on sites (i) outside of a manufactured home park or subdivision, (ii) in a new manufactured home park or subdivision, (iii) in an expansion to an existing manufactured home park or subdivision, or (iv) in an existing manufactured home park or subdivision on which a manufactured home has incurred "substantial damage" as a result of a flood, be elevated on a permanent foundation such that the bottom of the longitudinal structural I beam of the manufactured home including equipment or mechanical items is elevated to a minimum of one foot above the base flood elevation and be securely anchored to an adequately anchored foundation system to resist flotation, collapse, and lateral movement. c. All manufactured homes that are placed or substantially improved on sites in an existing manufactured home park or subdivision with Zone AE on the community's FIRM that are not subject to the provisions of subsection (4)b. of this section be elevated so that the bottom of the longitudinal structural I beam of the manufactured home including equipment or mechanical items is elevated to a minimum of one foot above the base flood elevation. (5) In areas shown as the Red River Special Flood Hazard Area on the map filed and maintained by the department of engineering and environmental services the following provisions apply: a. Encroachments, including fill, new construction, substantial improvements and other development shall be prohibited unless a technical evaluation demonstrates that encroachments shall not result in any increase in flood levels during the occurrence of the base flood discharge. b. The lowest floor or mechanical or electric equipment shall be elevated to a minimum of one and one-half feet above the high water mark. c. If subsections (a) and (b) above are satisfied, all new construction and substantial improvements shall comply with all applicable flood hazard reduction provisions of this division.

(Code 1971, § 15½-51; Ord. No. 136, 2016, 1-10-17; Ord. No. 36, 2019, 4-23-19; Ord. No. 1, 2021, 1-26-21; Ord. No. 64, 2021, 5-11-21)

Ask a question about Shreveport law

Corpus searches the Shreveport sections it holds and shows the ones that match, with their citations. Free, no sign-in.