§ 34-69 — Standards for areas of shallow flooding (AO and AH zones)
Code of Ordinances, City of Shreveport, Louisiana (Supp. No. 85, Update1: codified through Ordinance No.150, 2025 adopted December 9, 2025) · Shreveport City Code § 34-69
Corpus is an independent public-information project, not the official City of Shreveport website. Stable reference: corpuslaw.us/code/33d8a37e-be77-4122-9ae9-2e4b8a2f1c30
Sec. 34-69. - Standards for areas of shallow flooding (AO and AH zones).
Located within the areas of special flood hazard established in section 34-30 are areas designated as shallow flooding. These areas have special flood hazards associated with base flood depths of one to three feet, where a clearly defined channel does not exist and where the path of flooding is unpredictable and indeterminate; therefore, the following provisions apply: (1) New construction and substantial improvement of any structure with fully enclosed areas below the lowest floor that are subject to flooding shall be designed to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or meet or exceed the following minimum criteria: a. A minimum of two openings having a total net area of not less than one square inch for every one square foot of enclosed area subject to flooding shall be provided. b. The bottoms of all openings shall be no higher than one foot above the lowest adjacent grade. c. Openings may be equipped with screens, louvers, valves or other coverings or devices provided that they permit the automatic entry and exit of floodwaters. (2) New construction and substantial improvement of any residential structure shall have the lowest habitable floor including equipment or mechanical items elevated to a minimum of one foot above the base flood elevation. (3) New construction and substantial improvement of any commercial, industrial or other nonresidential structure shall either have the lowest floor including equipment or mechanical items elevated to a minimum of one foot above the base flood elevation; or, together with attendant utility and sanitary facilities, shall: a. Be floodproofed so that below the required flood protection level the structure is watertight with walls substantially impermeable to the passage of water; b. Have structural components capable of resisting hydrostatic and hydrodynamic loads and effects of buoyancy; and c. Be certified by a registered professional engineer or architect that the standards of this subsection are satisfied. Such certifications shall be provided to the official as set forth in section 34-50(2). (4) All manufactured homes shall be placed in accordance with section 34-66 and according to the following requirements: a. All manufactured homes to be placed within Zone A on a community's FIRM shall be installed using methods and practices which minimize flood damage. For the purposes of this requirement, manufactured homes must be elevated and anchored to resist flotation, collapse, or lateral movement. Methods of anchoring may include, but are not limited to, use of over-the-top or frame ties to ground anchors. This requirement is in addition to applicable state and local anchoring requirements for resisting wind forces. b. All manufactured homes that are placed or substantially improved within Zone AO or Zone AH on the community's FIRM on sites (i) outside of a manufactured home park or subdivision, (ii) in a new manufactured home park or subdivision, (iii) in an expansion to an existing manufactured home park or subdivision, or (iv) in an existing manufactured home park or subdivision on which a manufactured home has incurred "substantial damage" as a result of a flood, be elevated on a permanent foundation such that the bottom of the longitudinal structural I beam of the manufactured home including equipment or mechanical items is elevated to a minimum of one foot above the base flood elevation and be securely anchored to an adequately anchored foundation system to resist flotation, collapse, and lateral movement. c. All manufactured homes that are placed or substantially improved on sites in an existing manufactured home park or subdivision with Zone AO or Zone AH on the community's FIRM that are not subject to the provisions of subsection (4)b. of this section be elevated so that the bottom of the longitudinal structural I beam of the manufactured home including equipment or mechanical items is elevated to a minimum of one foot above the base flood elevation. (5) Adequate drainage paths around structures on slopes to guide floodwaters around and away from proposed structures shall be required.
(Code 1971, § 15½-53; Ord. No. 136, 2016, 1-10-17; Ord. No. 1, 2021, 1-26-21; Ord. No. 64, 2021, 5-11-21)
Ask a question about Shreveport law
Corpus searches the Shreveport sections it holds and shows the ones that match, with their citations. Free, no sign-in.
