Sec. 7-378. - Spray booths.

(a) Spray booths shall be substantially constructed of noncombustible material. (b) The interior surfaces of spray booths shall be smooth and continuous without edges and otherwise designed to prevent pocketing of residues and facilitate cleaning and washing without injury. (c) The floor of the spray booths and operator's working area if combustible, shall be covered with noncombustible, nonsparking material of such character as to facilitate the safe cleaning and removal of residues. (d) Distribution of baffle plates, if installed to promote an even flow of air through booth or cause the deposit of overspray before it enters the exhaust duct, shall be of noncombustible material and readily removable or accessible on both sides for cleaning. Such plates shall not be located in exhaust ducts. (e) Each spray booth having a frontal area larger than nine (9) square feet shall have a metal deflector or curtain not less than two and one-half (2½) inches deep installed at the upper outer edge of the booth, over the opening. (f) Each spray booth shall be separated from the other operations by not less than three (3) feet, or by a greater distance or by such partition or wall as the head of the fire department may require to reduce the danger from juxtaposition of hazardous operations. (g) Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than three (3) feet on all sides shall be kept free from storage or combustible construction. (h) When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination.

(Code 1965, § 7-156)

Ask a question about Brockton law

Corpus searches the Brockton sections it holds and shows the ones that match, with their citations. Free, no sign-in.