§ 7-381 — Ventilation of spray booths and spray finishing areas

Code of Ordinances of the City of Brockton, Massachusetts (Codified through Ordinance No. 07-31-2025(2), approved July 31, 2025 (Supp. No. 28)) · Brockton Code of Ordinances § 7-381

Corpus is an independent public-information project, not the official City of Brockton website. Stable reference: corpuslaw.us/code/60591f75-bd10-4175-96a6-eb36d21deabd

Sec. 7-381. - Ventilation of spray booths and spray finishing areas.

(a) All spraying areas shall be provided with mechanical ventilation adequate to prevent the dangerous accumulation of vapors. (b) Spraying operations shall not be conducted unless mechanical ventilation is in operation. (c) Each spray booth shall have an independent exhaust duct system discharging to building exterior, except multiple cabinet spray booths in which identical spray finishing material is used with a combined frontal area of not more than eighteen (18) square feet may have a common exhaust. If more than one fan serves one booth, all fans shall be so interconnected that one fan cannot operate without operating all. (d) Electric motors driving exhaust fans shall not be placed inside booths or ducts. Fan rotating element shall be nonferrous or non-sparking or the casing shall consist of or be lined with such material. (e) Belts shall not enter duct or booth unless belt and pulley within the duct or booth are tightly closed. (f) Exhaust ducts shall be constructed of steel and shall be substantially supported. (g) Exhaust ducts shall have a clearance from unprotected combustible construction or material of not less than eighteen (18) inches. If combustible construction is provided with the following protection applied to all surface within eighteen (18) inches, clearances may be reduced to the distances indicated: (1) Twenty-eight gauge sheet metal on one-fourth inch asbestos mill board, twelve (12) inches. (2) Twenty-eight gauge sheet metal on one-eighth inch asbestos mill board spaced out one inch on noncombustible spacers, nine (9) inches. (3) Twenty-two gauge sheet metal on one inch rockwool bats reinforced with wire mesh or the equivalent, three (3) inches. (h) Air exhausted from spraying operations shall not be recirculated.

(Code 1965, § 7-159)

Ask a question about Brockton law

Corpus searches the Brockton sections it holds and shows the ones that match, with their citations. Free, no sign-in.