Sec. 7-477. - Handling and use.

(a) Location. Flammable liquids in quantities requiring a license or permit shall be used in buildings, portions of buildings or rooms constructed and designed in accordance with the requirements of subsection (b). (b) Design and construction of inside mixing and handling rooms. Rooms shall have at least one exterior wall. Walls, floors and ceilings shall be of noncombustible construction having at least a one hour fire resistance rating. Door openings shall be provided with noncombustible liquid-tight sills at least six (6) inches high and provided with an approved fire door of the self-closing type. Adequate drainage to a safe location shall be provided. Adequate natural ventilation shall be provided or if mechanical ventilation is provided, installation shall be in accordance with national recognized good practice. Heating shall be by low pressure steam or hot water or by electrical units approved for Class I hazardous locations. All equipment such as mixers, filters, pumps, motors and shafting shall be permanently and effectively grounded. Electrical installations shall be made in accordance with nationally recognized safe practice. Compliance with the standards of the national board of fire underwriters known as the "National Electrical Code" shall be deemed prima facie evidence of compliance with nationally recognized safe practice. (c) Storage limits for inside mixing and handling rooms. An inside mixing and handling room not protected by an approved automatic fire-extinguishing system shall contain not more than eleven thousand (11,000) gallons total, of which not more than two thousand seven hundred fifty (2,750) gallons may be of Class I flammable liquids. These amounts may be increased to not more than one day's supply where daily consumption exceeds the above limits.

(Code 1965, § 7-195)

Ask a question about Brockton law

Corpus searches the Brockton sections it holds and shows the ones that match, with their citations. Free, no sign-in.