For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 19.50 — BUILDING AND SITE PLAN REQUIREMENTS

Code of Ordinances of the City of Cambridge, Massachusetts (Codified through Ordinance No. 2025-8, passed April 7, 2025 (Supp. No. 14)) · Cambridge Zoning Ordinance § 19.50

Corpus is an independent public-information project, not the official City of Cambridge website. Stable reference: corpuslaw.us/code/b8b8d28f-fc8b-4e94-9cad-ed6569144a8e

19.50 - BUILDING AND SITE PLAN REQUIREMENTS

19.51 Applicability. 19.51.1 Applicable Zoning Districts. This Section 19.50 shall apply in the following zoning districts: (1) All Office, Business, and Industrial Districts and NP districts, and any Special District for which an office, business or industrial district serves as the underlying base regulation (SD-1, SD-3, SD-5, SD-7, SD-8, and SD-11). (2) Residence C-1, C-1A, C-2, C-2A, C-2B, C-3, C-3A, and C-3B districts, and any Special District for which any one of these residence districts serves as the underlying base regulation (SD-2, and SD-6) for a building or portion of a building within one hundred (100) feet of a public street. 19.51.2 Applicable Construction. The building design and site development requirements set forth in this Section 19.50 shall be required for the following construction projects: (1) Any new building or structure of twenty-five thousand (25,000) gross square feet or more. (2) Any addition of twenty-five thousand (25,000) gross square feet or more to an existing building or structure. (3) Any alteration to the elements of a building of twenty-five thousand (25,000) gross square feet or more, or any alteration of its site, that is regulated by this Section 19.50, where the change is undertaken to accommodate a new use or uses or where the change is to a building constructed pursuant to a building permit certified to be in compliance with this Section 19.50 and where (a) the alterations to accommodate the new use are proposed to the exterior of the building, or on the lot outside the building and (b) those alterations would increase the extent to which the building or lot's physical configuration would violate the requirements set forth in Section 19.50 to a greater extent than the existing configuration. Where applicable zoning district regulations differ from the requirements of this Section 19.50, the stricter provisions shall apply. A project that does not comply with the requirements of this Section 19.50 shall not receive a building permit until a Special Permit is granted by the Planning Board. The Planning Board shall grant such special permit only upon finding that the project is consistent with the Urban Design Objectives set forth in Section 19.30. Nothing in this Section 19.50 shall prevent an applicant, not wishing to conform to the requirements of this Section 19.50, from directly seeking a special permit from the Planning Board subject to consistency with Section 19.30. Any application for a Building Permit for development subject to this Section 19.50 shall be accompanied by a Tree Study, certified complete by the City Arborist, as required by the Tree Protection Ordinance of the City of Cambridge, Chapter 8.66. 19.52 Heights, Setbacks and Building Façades. The provisions of this Section 19.52 shall not apply to Special District 8. (1) For development on a lot abutting a lot in a residential zoning district having a more restrictive height limit, the cornice line of the principal wall plane facing the residential zoning district line shall not exceed by more than twenty (20) feet at any point the maximum height permitted in the residential zoning district. Any portion of the building rising above the cornice line shall be located below a forty-five (45) degree bulk control plane starting at ground level at the zoning district line, subject to the following provisions. (a) Where the zoning district line lies within a lot, the bulk control plane shall begin at the lot line in the residential zoning district that divides the subject lot (including any intervening lots held in identical ownership but not part of the development lot and such lots located across the street) from another lot in different ownership. (b) Where the zoning district line occurs within a public street, the provisions of this Section 19.52 shall apply but the bulk control plane shall be measured from the centerline of the street regardless of the location of the zoning district line. (2) For development on a lot abutting a residential zoning district having more restrictive yard requirements, the yard requirements of the residential district shall apply to any portion of the development rising above the bulk control plane set forth in Paragraph (1) above. As in (1) above, where the zoning district line lies within a lot, the bulk control plane shall begin at the lot line in the residential zoning district that divides the subject lot (including any intervening lots held in identical ownership but not part of the development lot) from another lot in different ownership. This Paragraph (2) shall not apply where the zoning district line lies within or across a street. (3) A building footprint exceeding two hundred and fifty (250) feet in length, measured parallel to the street, shall contain a massing recess extending back at least fifteen (15) feet in depth measured from and perpendicular to the front lot line and at least fifteen (15) feet in width measured parallel to the front lot line so that the maximum length of unbroken façade is one hundred fifty (150) feet. (4) For portions of buildings containing residential uses, building façades shall incorporate architectural elements that project or recess by at least two feet from the adjacent section of the façade. Such projecting or recessed elements shall occur on an average interval of 40 linear horizontal feet or less for portions of the façade directly facing a public street, and on an average interval of 80 linear horizontal feet or less for other portions of the façade. Such projecting or recessed elements shall not be required on the lowest Story Above Grade or on the highest Story Above Grade, and shall not be required on the highest two Stories Above Grade of a building containing at least six Stories Above Grade. The intent is to incorporate elements such as bays, balconies, cornices, shading devices, or similar architectural elements that promote visual interest and residential character, and to allow variation at the ground floor and on upper floors where a different architectural treatment may be preferable. 19.53 Location of Uses. (1) In mixed-use developments containing a residential component (Section 4.31 - Residential uses, excluding Hotel and Motel use), the housing shall be located on the lot adjacent to existing residential uses located on abutting lots or across a street or shall be located adjacent to an existing abutting residential zoning district, including a district located across a street. (2) In mixed-use developments containing a retail component (Section 4.35 - Retail Business and Consumer Service Establishments), at least fifty (50) percent of the area devoted to retail uses shall be located fronting onto at least one of the public streets abutting the development. However, in multiple building developments where internal private streets open to the general public are created, retail uses may located on those private streets shall be deemed to meet the requirements of this Paragraph (2). 19.54 Historic Resources. No building permit pursuant to a Certificate of Compliance issued for a project subject to this Section 19.50 shall be issued until at least one of the following events has occurred: (1) The project has received, where applicable, a Certificate of Appropriateness, Hardship, or non-applicability from the Cambridge Historical Commission under the provisions of M.G.L. Chapter 40C and/or Chapter 2.78, Articles I or III, Cambridge city Ordinances, or from a Neighborhood Conservation District Commission under Chapter 2.78, Article III. (2) Where a building on the site has been determined by the Cambridge Historical Commission to be a Preferably Preserved Significant Building under the provisions of Chapter 2.78, Article II, Cambridge City Ordinances, or the six month demolition delay period has expired. 19.55 Landscaping. (1) The area between the principal wall plane of a building and a public street or public park, whether required or provided, shall be devoted to Green Area (as defined in Article 2.000), expansion of the adjacent public sidewalk, park area, or other landscaped area or paved pedestrian area and extending along the entire length of the lot facing the street or park. Areas devoted to motor vehicular use are prohibited from this area with the exception of access drives providing direct access to parking and service facilities located elsewhere on the site and which shall be limited to a total of thirty (30) feet of width for any individual driveway for each one hundred (100) feet of lot frontage. Where the front lot width is greater than three hundred (300) feet the provisions of this Paragraph shall only apply to that portion of the front yard extending beyond the side facades of the building, parallel to the front lot line or parallel to the adjacent park lot line, equal in length to the side yard setback(s) that would otherwise be required for the building in the district within which it is located. (2) The green area required in Paragraph (1) above shall initially be located at the mean grade of the relevant public street or open space at the property line. Beyond that point, a change in grade that can be maintained permanently without structural support shall be permitted. 19.56 Pedestrian Environment. The portion of the ground floor of a building (defined as the first floor of a building located either at mean grade or no more than four feet above the mean grade of the building) and the floors above that face and are within one hundred (100) feet of a public street or directly abuts and is within one hundred (100) feet of a public park shall consist of space routinely occupied by people throughout normal business hours engaged in those activities for which the building is principally intended to accommodate, including, but not limited to, retail stores sales areas; consumer service businesses; general, professional and agency offices; institutional offices, classrooms and dormitories; building lobbies, residential units, manufacturing and research and development activities, etc. (but excluding specifically parking and loading facilities), subject to the following requirements. (1) The actively used area shall have a depth of at least 20 feet, or the depth of the building if less. If the area is occupied by uses other than Residences or Dormitories, the height of the Ground Story for that portion of the building shall be at least fifteen (15) feet and the depth shall be at least thirty-five (35) feet on average measured from the portion of the façade that is nearest to the front lot line in a direction perpendicular to the street, and measured toward at least one street in instances where the space abuts two or more streets. (2) The facades shall consist of a minimum twenty-five (25) percent clear glass in total for the façade and at the ground floor subject to the following further provisions. (a) At the ground floor; the minimum amount of clear glass shall be increased to fifty (50) percent of the area of the façade of the ground floor where retail and office uses are established (Section 4.34 - Office and Laboratory Uses, Paragraphs a-e, and Section 4.35 - Retail Business and Consumer Service Establishments). For purposes of this Section 19.56, the area of the façade of any given floor shall be measured vertically from the finished interior floor to the underside of the structural joists of the floor above. (b) Where residential and dormitory uses are established, the minimum area of clear glass shall be reduced to twenty (20) percent of the entire façade, with no minimum requirement on the first floor. (c) No minimum requirement shall be imposed for Theaters (Section 4.35 h), Place of worship [Section 4.56 a (1)], College or university athletic facility, auditorium, and theater facility [Section 4.56 c (4)], Fire and police stations [Section 4.56 g (2)], Municipal service facility [4.56 g (4)], Museum [4.56 g (3)], and Transformer station, substation [Section 4.32 g (2)]. (3) Where retail uses are established, each separately leased space shall have an individual public entrance onto the abutting street where any portion of the space fronts towards the street; (4) At least one building entrance shall front on a street where the building abuts a street. (5) The façade of a Ground Story facing a public street shall consist of expanses no longer than twenty-five (25) feet in length, measured parallel to the street, which contain no transparent windows or pedestrian entryways. Where a freestanding parking garage is established, the requirements of this Section 19.55 shall apply only to the ground floor of the structure. Exempt from this requirement shall be one two-way access drive to accessory parking located elsewhere on the lot and the area necessary to meet the minimum zoning required for loading facilities provided that no more than twenty-five (25) percent of the total length of any one façade is occupied by all such facilities. 19.57 Parking. On-grade surface parking shall not be placed in front of the principal front wall plane of a building, extended across the entire width of a lot, unless the parking is screened from view from the public street by other buildings. Where the lot width at the Principal Front Wall Plane of the building is greater than 300 feet, the provisions of this paragraph shall only apply to that portion of the front yard extending beyond the side facades of the building, parallel to the front lot line, equal in length to the side yard setback(s) that would otherwise be required for the building in the district within which it is located. Where a lot abuts more than two streets, the provisions of this Section 19.57 shall apply to no more than two streets. 19.58 Mechanical Equipment, Refuse Storage, and Loading Areas. All mechanical equipment, refuse storage, or loading areas serving the building or its occupants that are (1) carried above the roof, (2) located at the exterior building wall or (3) located outside the building, shall meet the requirements listed below. Mechanical equipment includes, but is not limited to, ventilation equipment including exhaust fans and ducts, air conditioning equipment, elevator bulkheads, heat exchangers, transformers and any other equipment that, when in operation, potentially creates a noise detectable off the lot. The equipment and other facilities: (1) Shall not be located within any required setback. Where no setback is required, it shall not be located closer than 10 feet to any property line or it shall be entirely contained within the building. This Paragraph (1) shall not apply to electrical equipment whose location is mandated by a recognized public utility. (2) When on the ground, shall be permanently screened from view from adjacent public streets that are within 100 feet of the building, or from the view from abutting property in separate ownership at the property line. The screening shall consist of densely planted shrubs or trees equal or greater in height at the time of installation than the equipment or facilities to be screened, or a fence of equal or greater height that is comparable in quality to the materials used on the principal facades of the building, with no more than twenty-five (25) percent of the face of the fence open. When carried above the roof, shall be permanently screened from view, from the ground, from adjacent public streets and any abutting residentially used lot or lots in a residential zoning district. The screening shall be at least 50% opaque, uniformly distributed across the screening surface. (3) Shall be designed to meet all city, state and federal noise regulations, as applicable, as certified by a professional acoustical engineer if the Department of Inspectional Services deems such certification necessary. (4) That handle trash and other waste, shall be contained within the building or screened as required in this Section 19.58 until properly disposed of. 19.59 Open Space. At least 15% of the lot shall consist of any combination of Green Area or Permeable Open Space as defined in Article 2.000. This requirement may be met on a lot held in the same ownership, provided the Open Space is located within 300 feet of the development lot and does not serve to meet the requirement of this Section 19.59 for any other development. 19.510 Green Building Requirements. The requirements of Section 22.20 of this Zoning Ordinance shall be met.

(Ord. No. 2025-2, 2-10-2025)

Ask a question about Cambridge law

Corpus searches the Cambridge sections it holds and shows the ones that match, with their citations. Free, no sign-in.