§ 6-104 — Municipal system connection

Code of Ordinances of the City of New Bedford, Massachusetts (Codified through Ordinance of August 21, 2025. (Supp. No. 19)) · New Bedford Municipal Code § 6-104

Corpus is an independent public-information project, not the official City of New Bedford website. Stable reference: corpuslaw.us/code/f184eddd-b3a4-4acb-b12e-6e3673fa2649

Sec. 6-104. - Municipal system connection.

(A) Availability of municipal fire alarm circuit. Prior to planning the fire alarm system for a building, the applicant shall contact the fire alarm division of the city fire department for availability of a municipal fire alarm circuit. A plot plan shall be submitted to the fire alarm division. (B) Type of system. Complete information regarding the system proposed shall be submitted to the fire alarm division for approval. Such information shall include the proposed make and type of system involved, such as sprinklers, heat detectors, smoke detectors, and manual stations as well as standpipe systems. (C) Service to building. Cable must be furnished and installed from the master fire alarm box to a connection point into the municipal system, by the applicant. The connection point shall be designated by the fire alarm division. (D) Master box. Shall be located as close as possible to the main entrance. Consult fire alarm division as to proper location. Master box movement to be timed at one-half (½) second. Code number to be furnished after fire alarm division receives and approves initial fire alarm plans. (E) Location of annunciator. (1) Should an annunciated control panel be installed close to the main entrance, no remote annunciator is necessary. (2) Should a control panel be installed at some remote location such as an electric room, janitor's room, etc., an approved remote annunciator shall be installed at the main entrance. This remote annunciator shall have the following controls: (a) A remote system reset. (b) A remote trouble indicator panel with audible as well as visual signals. Means for silencing this trouble condition shall conform to subsection 6-105(D). (c) Evacuation alarm silencing switch. (F) Overhead service. The following materials, methods and procedures shall be used in the installation of overhead services: (1) Five-eighths (⅝) eyebolt or "D" bracket securely fastened to building. (2) Weather cap installed or rigid metal conduit or aluminum pipe. (3) Locate lightning arrestor between weather cap and point of attachment. (4) Lightning arrestor shall be properly grounded. (5) Install two (2) number 12 solid red wires from lightning arrestor to weather cap, to master box, in that order. (6) All splices shall be soldered. (G) Underground service. The following materials, methods and procedures shall be used in the installation of underground services: (1) An approved raceway shall be used throughout underground system. Consult fire alarm division as to size and type needed. (2) 12-2 U.F. cable or approved I.M.S.A. cable from junction in building to point of attachment, (pedestal or pole) designated by the fire alarm division. For longer distances, number 10 wire shall be used. From junction in building to master box, use same U.F. cable or two (2) solid red wires. All splices of fire department circuit shall be soldered. (3) Should construction change from underground to overhead, an approved lightning arrestor shall be used. (Brach 284-C or the equivalent.) Number 8 wire shall be run from arrestor to a driven ground rod (copper clad) with an approved grounding clamp; arrestor location to be designated by the fire alarm division. (4) Conductors on pole shall be protected up to ten (10) feet from ground level.

(Code 1963, § 8-505; Ord. of 8-20-81, § 1)

Ask a question about New Bedford law

Corpus searches the New Bedford sections it holds and shows the ones that match, with their citations. Free, no sign-in.