§ 3 — Pretreatment of wastewater
Code of the City of Frederick, Maryland (Codified through Ordinance No. G-26-1, adopted April 2, 2026. (Supp. No. 112, 8-26)) · Frederick City Code, App. L, § 3
Corpus is an independent public-information project, not the official City of Frederick website. Stable reference: corpuslaw.us/code/acc918fe-0bea-4fd7-b1bb-04cd47abcb61
§ 3. - Pretreatment of wastewater.
§ 3.1. Pretreatment facility or device. Each user shall provide wastewater treatment as necessary to comply with this Ordinance and any wastewater discharge permit issued under § 4 of this Ordinance and shall achieve compliance with all categorical pretreatment standards, the specific prohibitions established in § 2.3 and the local limits established in § 2.4 of this Ordinance within the time limitations specified by the EPA, the State, or the City, whichever is more stringent. Any pretreatment facility necessary for compliance shall be provided, operated and maintained at the user's expense. (a) Required. Every SIU shall provide, at the user's expense, facilities for preliminary treatment and handling industrial wastes as may be necessary to: (1) reduce BOD 5 to 300 mg/L; (2) reduce TSS to 250 mg/L; (3) reduce TKN to 30.0 mg/L; (4) reduce TP to 8.0 mg/L; (5) reduce objectionable characteristics or constituents to come within the maximum limits permitted in this Ordinance; or (6) control the quantities and rates of discharge over a 24-hour day or a 7-day week. (b) Excessive discharge. Discharge in excess of the limitations established in this section are subject to enforcement action and may be subject to a surcharge in accordance with § 12.3 of this Ordinance. (c) Grease trap required. Unless otherwise authorized by the Superintendent, any FSE newly constructed or renovated after the effective date of this Ordinance shall install and use a grease trap. Any other user, including an FSE in operation before the effective date of this Ordinance, must install a grease trap when, in the opinion of the Superintendent, a grease trap is necessary for the proper handling of wastewater containing excessive amounts of grease. (d) Grease trap requirements. All grease traps must be of type and capacity determined by a qualified engineer in accordance with the current requirements of the National Standard Plumbing Code and the City's Plumbing Code. Grease traps must be located to be easily accessible for cleaning and inspection. Users shall regularly inspect, clean, and repair their grease, oil, and sand interceptors at the users' own expense. (e) Deficiencies. Any FSE in operation as of the effective date of this Ordinance that is not using a grease trap sufficient to prevent floatable FOG or solids from entering the wastewater collection system will be notified, in writing, of the deficiencies and required improvements and provided a compliance deadline. The FSE shall be required to provide a schedule whereby corrections will be accomplished. (f) Exemption. If a user demonstrates to the Superintendent that the installation of a grease trap is impractical due to existing conditions or grease trap installation would conflict with other applicable laws or standards, the user shall: (1) construct an appropriate sampling point at the user's expense; (2) locate the sampling point in a manner that provides ready and easy accessibility for inspection and sampling; and (3) maintain the sampling point in an effective operating condition. § 3.2. Pretreatment facility design and construction. Detailed plans and specifications describing such facilities and operating procedures shall be submitted to the City for review, and shall be acceptable to the Superintendent and any other governmental regulatory body having jurisdiction before such facilities are constructed. The review of such plans and operating procedures shall in no way relieve the user from the responsibility of modifying such facilities as necessary to produce a discharge acceptable to the City under the provisions of this Ordinance. § 3.3. Operation and maintenance of pretreatment facility or device. (a) Generally. A facility for pretreatment and handling of industrial wastes provided by the owner of an improved property must be continuously maintained in satisfactory operating condition at the expense of the owner. The Superintendent shall have access to each facility at all times for purposes of inspection and testing. (b) Grease traps. (1) Each user shall, at the user's own expense, inspect, clean and repair grease traps in accordance with this Ordinance and the City's FOG Control Program. (2) Unless otherwise authorized by the Superintendent, all grease traps shall be pumped out completely, by a Frederick County permitted liquid waste hauler, when the total accumulation of FOG (including floating solids) and settled solids reaches 25% of the grease trap's overall liquid depth or at least once every 90 days, whichever is more stringent, and in no case less than once every six months. Exception to this minimum frequency of pumping may be made with special written approval from the Superintendent for generators of small quantities of grease wastes. (3) A person may not introduce or allow to be introduced into grease traps or associated plumbing any additive such as bacteria, enzymes, emulsifiers, or similar chemicals designed for the purpose of emulsifying or controlling FOG discharge. (4) Owners of commercial properties are responsible for the installation and maintenance of a grease trap that serves multiple FSEs that are located on a single parcel or development. (c) Reduction in discharge. The Superintendent may require a user to restrict their discharge during peak flow periods, designate that certain wastewater be discharged only into specific sewers, relocate and/or consolidate points of discharge, separate sewage wastestreams from industrial wastestreams, and such other conditions as may be necessary to protect the POTW and determine the user's compliance with the requirements of this Ordinance. (d) Flow equalization. The Superintendent may require any person discharging into the POTW to install and maintain, on their property and at their expense, a suitable storage and flow-control facility to ensure equalization of flow. An individual wastewater discharge permit may be issued solely for flow equalization. (e) Users with potential for discharge of flammable substances may be required to install and maintain an approved combustible gas detection meter. § 3.4. Plumbing system preventative maintenance. (a) Sewer line. The on-site sanitary sewer line system for a property containing a FSE, multi-tenant properties containing at least one FSE, and properties containing multi-family housing buildings must be professionally cleaned, at the expense of the property owner, at least once every 365 days. The Superintendent may specify additional maintenance if once per year is shown to be inadequate. All debris accumulation in the service lines professionally cleaned must be collected for disposal. A property owner shall notify the Superintendent no later than 48 hours before scheduled maintenance. (b) BMPs. All users shall implement BMPs to prevent or reduce the quantity of FOG discharged to the pretreatment device and sanitary sewer system. BMPs include: (1) good housekeeping measures; (2) operations management techniques to include employee training; (3) spill control plans; and (4) proper waste disposal methods, including "no grease" signs posted above sinks and on the front of dishwashers, written in the languages most commonly spoken by employees.
(Ord. No. G-15-08, § II, 5-7-15; Ord. No. G-19-37, § V, 12-5-19)
Ask a question about Frederick law
Corpus searches the Frederick sections it holds and shows the ones that match, with their citations. Free, no sign-in.
