For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 9 — Fees and charges

Code of the City of Frederick, Maryland (Codified through Ordinance No. G-26-1, adopted April 2, 2026. (Supp. No. 112, 8-26)) · Frederick City Code, App. L, § 9

Corpus is an independent public-information project, not the official City of Frederick website. Stable reference: corpuslaw.us/code/6df58ae9-4b3c-4726-b9fb-75c4feb94a2e

§ 9. - Fees and charges.

§ 9.1. Fees. (a) Adoption. The Board of Aldermen may, by ordinance, adopt reasonable fees for the reimbursement of costs incurred in setting up and operating the City's industrial pretreatment program. (b) Types of fees. Fees adopted under this section may include the following: (1) fees for monitoring, inspection, and surveillance procedures; (2) fees for reviewing and responding to accidental discharge procedures and construction; (3) fees for permit application review and processing; (4) fees for the treatment of excessive discharges of TKN, TP, BOD 5 and TSS; and (5) other fees as the City deems necessary to carry out the requirements of this Ordinance. These fees relate solely to the matters covered by this Ordinance and are separate from all other fees chargeable by the City. § 9.2. Characterization of industrial wastes for surcharge purposes. (a) Volume. The volume of industrial wastewater for surcharge purposes from users obtaining water from the City will be determined by a method which identifies and quantifies: (1) domestic usage, QD (2) unpolluted cooling water discharged to a separate storm sewer or other outlet, QC (3) makeup water used to replace evaporative loss in closed-cycle cooling system, QM (4) water used as part of a manufactured product, QP (5) total water used, QT (6) the determined industrial wastewater flow, QI (b) Flow. The determination for industrial wastewater flow for surcharge purposes, QI, shall be as follows: QI = QT - (QD + QM + QP + QC) (c) Values. The values for the various terms in the formula above will be determined by direct metering or by calculation in a manner agreed upon by the Superintendent and the user, more specifically: (1) The total water used, QT shall be metered by the City. (2) The water flow for domestic usage, QD, may be determined by metering the flow if the piping at the job site allows for separation of domestic water from process related water usage, or, the value of QD may be calculated by multiplying the average number of full time employees at the job site per day by 10 gallons per day. Another usage factor may be used if the user can establish validity. (3) The value of QC, the unpolluted cooling water discharge flow, shall be determined by metering the discharge with meters installed, maintained and calibrated at the expense of the user and to the satisfaction of the Superintendent. (4) The value of QM, the makeup water for closed circuit cooling systems, shall be determined by metering the water supply to the system with meters installed, maintained and calibrated at the expense of the user and to the satisfaction of the Superintendent. (5) The volume of water used as part of a manufactured product, QP, will be calculated by a means appropriate to the manufacturing method or product procedure and shall be approved by the Superintendent. (6) Should the industrial user wish not to account for water used but not discharged to the POTW - i.e., QC, QM, or QP - these terms will be metered to assure the value is zero when calculating the industrial wastewater volume. (d) Short term discharge. Whenever a person using a private water supply discharges non-domestic wastes to the City's POTW during a one-time discharge event or short-term discharge event of less than six months, the charges for such discharge shall be defined either in the contractual agreement with the City and the user or in a discharge permit. A user shall install at the user's expense a suitable meter or meters, as may be required by the City to measure the total volume of water used in the user's property; or shall install, at the user's expense, a meter on the sewer line leaving the user's property so as to measure the entire flow of waste discharged into the sewer system. (e) Meters. A person may not install a meter for the measurement of water or sewage until a plan for installation is submitted to and approved by the Superintendent. All meters or other measuring devices installed or required to be used under the provisions of this Ordinance shall be tested, inspected, or repaired as required by the Superintendent. The owner of the property upon which a meter or other measuring device is installed is responsible for its maintenance and safekeeping. Any repairs to a meter or other measuring device must be made by the property owner at the property owner's expense. § 9.3. Industrial waste surcharge. There shall be additional charges for industrial wastes having concentrations of BOD 5 in excess of 300 mg/L, TSS in excess of 250 mg/L, TKN in excess of 30 mg/L and TP in excess of 8 mg/L. These charges shall be determined using the following formula: S = (0.00834 * (QI (BODI - 300)(TA) + (SSI - 250)(TB)) + (0.0834 * (QI(TKNI - 30)(TC) + (TPI - 8)(TD)) S is the semi-annual surcharge to be added to the normal sewer rent. 0.00834 is a constant to convert waste concentrations expressed in mg/L to thousands of pounds of waste. 0.0834 is a constant to convert waste concentrations expressed in mg/L to hundreds of pounds of waste. QI is the semiannual industrial wastewater flow expressed in million gallons and determined as per methods set out in this section. BODI, SSI, TKNI and TPI are the average concentrations of BOD 5, suspended solids, total kjeldahl nitrogen and total phosphorus in the user's wastestream expressed in mg/L for the billing period. TA is the treatment cost per 1,000 pounds of BOD 5 . TB is the treatment cost per 1,000 pounds of suspended solids. TC is the treatment cost per 100 pounds of total kjeldahl nitrogen. TD is the treatment cost per 100 pounds of total phosphorus. § 10. Confidential Information. Information and data on a user obtained from reports, surveys, wastewater discharge permit applications, individual wastewater discharge permits, and from the Superintendent's inspection and sampling activities, shall be available to the public without restriction, unless the user specifically requests, and is able to demonstrate to the satisfaction of the Superintendent, that the release of such information would divulge information, processes, or methods of production entitled to protection as trade secrets under the Maryland Public Information Act. Any such request must be asserted at the time of submission of the information or data. When requested and demonstrated by the user furnishing a report that such information should be held confidential, the portions of a report which might disclose trade secrets or secret processes shall not be made available for inspection by the public, but shall be made available immediately upon request to governmental agencies for uses related to the NPDES program or pretreatment program, and in enforcement proceedings involving the person furnishing the report. Wastewater constituents and characteristics and other effluent data, as defined at 40 CFR 2.302 shall not be recognized as confidential information and shall be available to the public without restriction.

(Ord. No. G-15-08, § II, 5-7-15; Ord. No. G-19-37, § X, 12-5-19) (Ord. No. G-19-37, § XI, 12-5-19)

Ask a question about Frederick law

Corpus searches the Frederick sections it holds and shows the ones that match, with their citations. Free, no sign-in.