Sec. 11-14. - Amendments and modifications to the NFPA codes governing construction.
The Standard for Fire Doors and Other Opening Protectives (NFPA 80), 2022 Edition, and the Life Safety Code® (NFPA 101®), 2024 Edition, are modified as follows: (1) NFPA 80,4.7.1. Add the following: "Release of fire doors and shutters shall not be solely by fusible link, and shall be activated by one or more of the following methods: (1) Approved local smoke detection at the protected opening. (2) Approved area smoke detection per NFPA 72. (3) Fully automatic sprinkler protection per NFPA 13." (2) NFPA 101, General. Delete all references to NFPA 5000, Building Construction and Safety Code, 2024 Edition, and substitute "the City of Gaithersburg Building Code." (3) NFPA 101, 2.2 and 2.4. Delete the referenced publication NFPA 150, Fire and Life Safety in Animal Housing Facilities Code, 2022 Edition. (4) NFPA 101 3.3.24.8.1. Add new subsection 3.3.24.8.1 to read as follows: "Work Area- Any portion of a residential or commercial building that is re-constructed, reconfigured, altered, repaired or renovated from its original design as determined by the City Fire Marshal. Exception: 1. Removal and replacement of interior wall and ceiling finishes for the sole purpose of remediation of smoke damage, water or flood damage, or mold remediation." (5) NFPA 101, 3.3.66.3. Add new subsection 3.3.66.3 to read as follows: "3.3.66.3 Bulkhead Door. A type of door assembly covering an opening in the ground providing direct access to a basement, the floor of which is not more than 8 feet below ground level. A Bulkhead Door consists of a single rigid leaf or two overlapping rigid leaves or covers which need to be pushed or lifted upwards in order to be opened. A person, after opening the door, can walk up a series of steps to escape to the outside." (6) NFPA 101, 3.3.70.1. Replace the word "three" with "five" and delete the phrase "if any, accommodated in rented rooms." (7) NFPA 101, 3.3.134. Add "(See 4.6.17 with City amendments for establishing Grade Plane)." (8) NFPA 101, 3.3.154.1. Delete the phrase "more than three, but." (9) NFPA 101, 3.3.205.4. Delete the phrase "four or more." (10) NFPA 101, 3.3. 205.12. Replace the word "four" with "six." (11) NFPA 101, 3.3.289. After the word "discharge," insert "or the first story above grade plane, whichever is lower," and add "(See also 4.6.3.)." (12) NFPA 101, 4.5.8. Delete the phrase "for compliance with the provisions of this Code." (13) NFPA 101, 4.6.3(1) and 4.6.3(2). After the phrase "level of exit discharge" insert "or first story above grade plane, whichever is lower." (14) NFPA 101, 4.6.3(5). Delete. (15) NFPA 101, 4.6.10.2. Replace the phrase "Where required by Chapters 11 through 43, construction" with "Construction." (16) NFPA 101, 4.6.12.1. Delete the phrase "for compliance with the provisions of this Code." (17) NFPA 101, 4.6.12.3. Delete the phrase "by the Code." (18) NFPA 101, 4.6.17. Replace both occurrences of the phrase "6 ft (1.8m)" with "20 ft." (19) NFPA 101, 4.8.2.4. Add new subsection 4.8.2.4 to read as follows: "4.8.2.4 Emergency action plans shall be maintained in a location approved by the City Fire Marshal." (20) NFPA 101, 6.1.4.1. Delete the phrase "four or more." (21) NFPA 101, 6.1.8.1.1. Replace the word "three" with "five" and delete the phrase ", if any, accommodated in rented rooms." (22) NFPA 101, 6.1.9.1. Replace the word "four" with "six." (23) NFPA 101, 7.1.3.2.1(8) (a). Delete the text and replace with the following: "Existing previously approved openings." (24) NFPA 101, 7.1.10.3. Add new subsection 7.1.10.3 to read as follows: "7.1.10.3 Trash or recyclable materials awaiting scheduled collection shall not be placed in exits, exit access corridors, or on egress balconies." (25) NFPA 101, 7.2.1.2.2.2(5). Add new subparagraph 7.2.1.2.2.2(5) to read as follows: "(5) For power operated sliding door assemblies that utilize stacking sliding panels or a fixed panel adjacent to and on the exterior of the sliding panel(s), and the door system is designed such that the panels break away to become side hinged in the emergency breakout mode, the width of means of egress shall be permitted to be no more than the combined width of the fixed panel and the moving panels, minus 32 inches for each sliding panel." (26) NFPA 101, 7.2.1.4.3.1. After the phrase "or a landing unobstructed" insert "and shall not project more than 7 inches into the required width when fully open" and in parenthetical subparagraph (2) delete all text after the phrase "The door" and replace with "leaf projects not more than 7 inches into the required width of the stair landing when the door leaf is fully open." (27) NFPA 101, 7.2.1.4.4.3.2. Delete. (28) NFPA 101, 7.2.1.6.4.1. After the phrase "Where permitted", insert "by the City Fire Marshal and." (29) NFPA 101, 7.2.1.7.1. Delete the phrase "required to be." (30) NFPA 101, 7.2.1.7.4. Replace the phrase "Required panic hardware" with "Panic hardware." (31) NFPA 101, 7.2.1.14.1 and 7.2.1.15.1. After the phrase "Where required by" insert "the City Fire Marshal and." (32) NFPA 101, 7.3.1.1.1. Delete all text after the phrase "occupant load thereof." (33) NFPA 101, Table 7.3.1.2. Under "Business Use," change "150" to "100," and add "New Business Occupancy shell space shall be calculated at 65 ft² (6.0 m²) per person." (34) NFPA 101, 7.9.1.2. In the first sentence, replace the word "only" with ", but not be limited to,". (35) NFPA 101, 7.10.8.3.2(5). Add new subparagraph 7.10.8.3.2(5) to read as follows: "(5) When located at a door, the sign shall be visible with the door in any position, or if the sign is located on the door, the door shall be self-closing." (36) NFPA 101, 8.6.7(6)(b). Delete all text after the word "are" and replace with "located at the annunciator panel, in the Fire Control Room, or other location approved by the City Fire Marshal." (37) NFPA 101, 8.7.3.3. Add the following exception: "Exception: Unless other criteria are approved by the City Fire Marshal." (38) NFPA 101, 9.6.1.3. Delete the phrase "required by this Code." (39) NFPA 101, 9.6.2.6. Add the following: "This paragraph does not permit the omission of manual fire alarm boxes in accordance with other provisions of this subsection unless specifically permitted by Chapters 11 through 43." (40) NFPA 101, 9.6.2.10.6. Replace the phrase "in accordance with the requirements of NFPA 72" with "by the building's electric service and shall have battery back-up." (41) NFPA 101, 9.6.3.4. Delete all text after the word "delay" and replace with "to a listed central station in accordance with 9.6.4." (42) NFPA 101, 9.6.3.5. At the end of the sentence, add the phrase "and only when the initial fire alarm signal is automatically transmitted without delay to a listed central station in accordance with 9.6.4." (43) NFPA 101, 9.6.3.7.2. Add the following: "Where selective evacuation is used in high rise buildings, occupant notification shall be by voice announcement and shall send a predetermined message to the floor where the fire alarm originated, to the floor immediately below and to the floor immediately above, providing information and directions to the occupants. Any subsequent alarm(s) other than the initial fire floor must initiate the voice notification as described above. The voice notification shall be designed to be heard clearly by all occupants within the designated portions. Communicating levels (open to one another) shall be considered one floor/fire area for the audible and visual fire alarm signals." (44) NFPA 101, 9.6.3.7.4 and 9.6.3.7.5. Replace the phrase "be required" with "sound automatically." (45) NFPA 101, 9.6.3.10. Add the following: "New systems having voice notification shall be by automatic, pre-recorded announcement in accordance with Section 9.6. Live voice as the sole means of notification method is prohibited." (46) NFPA 101, 9.6.4.2. Delete all text after the word "automatically" and replace with "to a listed central station." (47) NFPA 101, 9.6.4.3. Delete. (48) NFPA 101, 9.6.6.2(3). Add the following exception: "Exception to (3): Manual fire alarm initiation shall not activate floor- or zone-dependent smoke control systems." (49) NFPA 101, 9.6.8.2. Add the following: "Annunciation shall comply with the requirements set forth in NFPA 72, as amended by the City Fire Code." (50) NFPA 101, 9.6.8.3. Delete all text after the word "zone." (51) NFPA 101, 9.6.8.4. Delete all text after the word "direction." (52) NFPA 101, 9.6.8.4.1, 9.6.8.4.2, 9.6.8.4.3, 9.6.8.4.4, and 9.6.8.4.5. Delete. (53) NFPA 101, 9.7.1.1.1. Add new subsection 9.7.1.1.1 to read as follows: "9.7.1.1.1 For new ceiling installations, drop-out ceilings as referenced in NFPA 13 and NFPA 13R shall be prohibited." (54) NFPA 101, 9.7.1.3. Replace the phrase "NFPA 13 Standard for the Installation of Sprinkler Systems" with "valved with the domestic water system," and at the end of the paragraph add "Any and all work shall be performed only by a sprinkler contractor that has a current, valid Maryland Sprinkler Contractor license." (55) NFPA 101, 9.7.2.2.1. Delete all text after the phrase "waterflow alarms shall be" and replace with "automatically transmitted to a listed central station." (56) NFPA 101, 9.8.1. Delete the text and replace with the following: "Where water as an extinguishing agent is not compatible with the fire hazard or is prohibited by law, statute or ordinance, the affected area shall be equipped with an approved automatic fire suppression system utilizing a suppression agent that is compatible with the fire hazard. Automatic fire-extinguishing systems installed as an alternative to required automatic sprinkler systems must be approved by the City Fire Marshal. All such systems shall be installed in accordance with the appropriate standard as determined in Table 9.8.1." (57) NFPA 101, 9.11.1. Delete the phrase "required by this Code." (58) NFPA 101, 9.11.2. Add the following: "When a fire watch is deemed necessary due to a system impairment and the property owner or the owner's agent cannot be contacted to establish a fire watch, the City of Gaithersburg at their discretion may provide the fire watch and charge the property owner the inspection overtime rate per person per hour." (59) NFPA 101, 9.11.4.1, 9.11.4.2 and 9.14.1. After the phrase "Where required by," insert "the City Fire Marshal and." (60) NFPA 101, 10.4.1 and 10.5.1. At the beginning of each sentence, insert "Where required by the City Fire Marshal,". (61) NFPA 101, 11.8.6.1. Replace the phrase "fire department" with "City Fire Marshal," and add the following: "In new construction, the emergency command center shall have a door directly to the exterior of the building located as approved by the City Fire Marshal, and the exterior face of the door shall be marked with a plainly visible and legible sign stating "FIRE COMMAND CENTER" or similar approved wording. In addition to the provisions of 11.8.6.2 the fire command center shall also comply with Section 911 of the 2024 Edition of the International Building Code." (62) NFPA 101, 11.8.6.2. Replace the phrase "fire department" with "City Fire Marshal." (63) NFPA 101, 11.8.6.6(6). Add the following: "and remote starting only." (64) NFPA 101, 11.11.2.1. Add the following: "or other testing standard approved by the State Fire Marshal." (65) NFPA 101, 11.12.2, 12.2.1.2, 12.2.2.2.4 and 13.2.2.2.4. Delete. (66) NFPA 101, 12.2.4.1 and 13.2.4.1. Add the following: "(1) Not less than two separate exits shall be provided on every story. (2) Not less than two separate exits shall be accessible from every part of every story." (67) NFPA 101, 12.3.4.3 and 13.3.4.3.3. Delete all text after the title "Notification," and replace with "Occupant notification shall be via an automatic, pre-recorded announcement in accordance with Section 9.6.3 as amended by the City Fire Code. Live voice as the sole means of notification method is prohibited." (68) NFPA 101, 12.3.4.3.1, 13.3.4.3.1 and 13.3.4.3.2. After the word "permitted", insert "only where specifically allowed by the City Fire Marshal." (69) NFPA 101, 12.3.4.3.3 and 13.3.4.3.3. Delete all text after the phrase "in accordance with 9.6.3.10 and add the following: "In areas that have music sound systems, video game systems, or other systems that produce noise levels such that the ambient noise would inhibit the audibility of the fire alarm system notification, such systems must be arranged to automatically shut down upon activation of the fire alarm." (70) NFPA 101, 12.3.4.3.4. Delete the phrase "initiated by the person in the constantly attended receiving station,". (71) NFPA 101, 12.3.4.3.6, 12.3.4.3.7, 13.3.4.3.6 and 13.3.4.3.7. Delete. (72) NFPA 101, 12.3.5.1. Add the following Exception: "Exception: Where the Assembly occupancy meets all of the following: (1) Occupant loads of less than 100 persons. (2) Occupancy is less than 5,000 square feet in area; and (3) Occupancy is located on a level of exit discharge." (73) NFPA 101, 14.2.1.5. Delete. (74) NFPA 101, 14.2.3.2.2. Replace the phrase "with a required capacity" with "serving areas with a total occupant load." (75) NFPA 101, 14.2.11.1.1(1). After the word "tools", insert ", keys, special knowledge, or excessive force,". (76) NFPA 101, 14.7.2.3(1)(b) and 15.7.2.3(1)(b). Delete the text and replace with the following: "A minimum total of eight emergency drills shall be conducted during the school year, with at least three conducted within four months of the beginning of the school year. Exception to (b): For educational occupancies in buildings protected throughout by an automatic sprinkler system, the total number of emergency drills conducted during the school year shall be five, with at least two conducted within four months of the beginning of the school year." (77) NFPA 101, 15.2.2.2.4.1(3) and 17.2.2.2.6.1(3). Delete the text and replace with the following "Where approved by the City Fire Marshal, two nonsimultaneous releasing motions shall be permitted if the locking devices are readily distinguishable as locked." (78) NFPA 101, 15.2.4.2(3). Delete. (79) NFPA 101, 16.1.1.1 and 17.1.1.1.1. Add the following exception: "Exception: Day-care centers providing care for school age children before and/or after school hours in a building which is in legal use as a public or private school are not required to meet the provisions of this chapter but shall meet the provisions for educational occupancies." (80) NFPA 101, 16.2.1.1. Delete. (81) NFPA 101, 16.2.11.1.1 & 17.2.11.1.1. Add the following exception: "Exception to (3): For windows at grade, the minimum net clear opening shall be permitted to be 5.0 ft²." (82) NFPA 101, 16.3.4.5 and 17.3.4.5 Add the following exception: "Exception to (1): In buildings equipped with a selective evacuation fire alarm system, smoke detection at stairwell doors shall only be required at locations that would activate the alarm in the day-care center." (83) NFPA 101, 16.3.5.1. Add the following exception: "Exception: Automatic sprinkler protection is not required where all the following conditions are met: (1) The occupancy in which the day-care center is located does not exceed 12,000 sq. ft. in area and has a total occupancy load of not more than 300 people. (2) All rooms used for day care is located on a level of exit discharge. (3) All rooms used for day-care have at least one exterior exit door at grade level." (84) NFPA 101, 16.6.1.1.2 and 17.6.1.1.2. Delete the phrase "more than 3, but." (85) NFPA 101, 16.6.1.4.1.1 and 17.6.1.4.1.1.1. Delete the phrase "more than three, but", and change "seven" to "nine." (86) NFPA 101, 16.6.1.4.1.2 and 17.6.1.4.1.2. Change "7" to "9." (87) NFPA 101, 16.6.1.7.1 and 17.6.1.7.1. Delete the text and replace it with the following: "In family day-care homes, a day-care provider's own children incapable of self-preservation shall be counted as clients served, and the following shall apply: (1) At any given time, a day-care provider may not care for more than eight clients, of whom no more than four may be incapable of self-preservation; and (2) An adult-to-child ratio of at least one adult to every two children incapable of self-preservation shall be maintained at all times. Exception to (2): If approved by the City Fire Marshal, the staff-to-client ratio may be modified where safeguards are provided in addition to those specified by local codes and ordinances." (88) NFPA 101, 16.6.2.1.2. Delete. (89) NFPA 101, 16.6.2.2 and 17.6.2.2.2. Replace the word "Reserved" with the following: "Sliding door. For family day-care homes, a sliding door used as a required means of escape shall comply with the following conditions: (1) The sliding door shall have not more than one, easily operated, locking device that does not require special knowledge, effort, or tools to operate. (2) There may not be draperies, screens, or storm doors that could impede progress. (3) The sill or track height may not exceed 1/2 inch above the interior finish floor. (4) The surface onto which exit is made shall be an all-weather surface such as a deck, patio, or sidewalk. (5) The floor level outside the door may be one step lower than the inside, but not more than 8 inches lower. (6) The sliding door shall open to a clear open width of at least 28 inches. (7) Before day-care use each day, the sliding door shall be unlocked and tested to the full required width to be sure it is operating properly, and the door shall be nonbinding and slid easily; and (8) During periods of snow or freezing rain, door tracks shall be cleared out and the door opened periodically throughout the day in order to ensure proper operation." (90) NFPA 101, 16.6.2.3 and 17.6.2.3. Replace the word "Reserved" with the following: "Special means of escape requirements. For family day-care homes, any door in a required means of escape may be provided with a deadbolt lock only if the lock is openable with approved interior mechanism, or the lock shall be of a captured-key design from which the key cannot be removed from the interior side of the lock when the lock is in the locked position." (91) NFPA 101, 16.6.2.4.5 and 17.6.2.4.5. Add the following exception: "Exception to (3): Bulkhead doors shall not serve as a primary means of escape." (92) NFPA 101, 17.6.3.4.5. Delete. (93) NFPA 101, 22.4.6.1.3. Delete the phrase "or 22.4.6.1.5." (94) NFPA 101, 22.4.6.1.5 and 22.4.6.2. Delete section 22.4.6.1.5 and delete section 22.4.6.2 and all subsections. (95) NFPA 101, 23.4.6.1.3. Delete the phrase "or 23.4.6.1.5." (96) NFPA 101, 23.4.6.1.5 and 23.4.6.2. Delete section 23.4.6.1.5 and delete section 23.4.6.2 and all subsections. (97) NFPA 101, 24.1.1.2. Replace the word "three" with "five" and delete the phrase ", if any, accommodated in rented rooms." (98) NFPA 101, 24.2.2.3.3. After the phrase "5.7 ft² (0.53 m²)" insert "or not less than 5.0 ft² when at grade." (99) NFPA 101, 24.2.8. Delete the section and all subsections. (100) NFPA 101, 24.3.4.1.3. Add the following: "in locations that were not required to have smoke alarms at the time the dwelling was constructed." (101) NFPA 101, 26.1.1.1. After the word "buildings" insert "that do not qualify as one-and two-family dwellings, and." (102) NFPA 101, 26.2.4. Delete. (103) NFPA 101, 26.3.4.5.1. Delete the text and replace with the following: "Approved smoke alarms shall be installed in accordance with 9.6.2.10 on every level of the building, in every sleeping room and outside of each separate sleeping area in the immediate vicinity of the sleeping rooms." (104) NFPA 101, 26.3.4.5.3 and 28.2.1.4. Delete. (105) NFPA 101, 28.3.4.3.6. Delete all text after the word "provided." (106) NFPA 101, 29.3.4.5.2 and 30.2.1.3. Delete. (107) NFPA 101, 30.3.4.3.3. Delete the phrase ", unless the building complies with either 30.3.4.3.4. or 30.3.4.3.5." (108) NFPA 101, 30.3.4.3.4 and 30.3.4.3.5. Delete. (109) NFPA 101, 31.3.4.5.1. Delete the phrase ", as modified by 31.3.4.5.2,". (110) NFPA 101, 31.3.4.5.2. Delete. (111) NFPA 101, 31.3.4.5.3. Delete the phrase "or a complete, supervised automatic sprinkler system in accordance with 31.3.5." (112) NFPA 101, 31.3.4.5.4. Add the following: "in sleeping rooms that were not required to have smoke alarms at the time the building was constructed." (113) NFPA 101, 32.1.3.4. Replace the phrase "unless the board and care occupancy is" with "unless the board and care occupancy and exits therefrom are." (114) NFPA 101, 32.2.2.3.1(3). After the phrase "5.7 ft² (0.53 m²)" insert "or not less than 5.0 ft² when at grade." (115) NFPA 101, 32.2.2.7 and 32.3.2.1.3. Delete. (116) NFPA 101, 32.7.5.2.2 and 32.7.5.3.2. Delete all text after the word "tested." (117) NFPA 101, 33.2.2.3.1(3). After the phrase "5.7 ft² (0.53 m²)" insert "or not less than 5.0 ft² when at grade." (118) NFPA 101, 33.2.3.4.4.1. Delete all text after the phrase "in accordance with 9.6.2.10." (119) NFPA 101, 33.2.3.4.4.3. After the word "for", insert "sleeping rooms,". (120) NFPA 101, 33.2.3.4.4.5. After the word "system," insert "and have secondary battery backup," and add the following exception: "Exception: Unless another state or local fire prevention code or building code or similar governmental code requires smoke alarms to be powered by the building electrical service, smoke alarms installed in sleeping rooms in order to comply with this section may be battery-powered without secondary power." (121) NFPA 101, 33.2.3.4.4.6 and 33.2.3.4.4.7. Delete. (122) NFPA 101, 33.3.3.4.7. Delete all text after the phrase "in accordance with 33.3.3.4.7.1." (123) NFPA 101, 33.3.3.4.7.2 and 33.3.3.4.7.3. Delete. (124) NFPA 101, 33.3.3.4.8.1. Delete the phase "33.3.3.4.8.2 and." (125) NFPA 101, 33.3.3.4.8.2. Delete. (126) NFPA 101, 33.7.5.2.2 and 33.7.5.3.2. Delete all text after the word "tested." (127) NFPA 101, 36.2.1.6. Delete the section and all subsections. (128) NFPA 101, 36.2.5.11(4). Add the following: The egress path shall be defined by a fixed barrier or guardrail with at least one intermediate rail. The fixed barrier or guardrail shall be at least 42 inches above the adjacent walking surface, and any openings in the fixed barrier or guardrail for passage shall be limited to a maximum of 36 inches width." (129) NFPA 101, 36.3.1(5). Delete the phrase "and the number of contiguous stories shall not be limited." (130) NFPA 101, 36.3.4.1. After the phrase "Class A'", insert "and multiple story Class B." (131) NFPA 101, 37.2.5.11(4). After the word "defined" insert "with fixed barriers." (132) NFPA 101, 37.3.4.1. After the phrase "Class A," insert "and multiple story Class B." (133) NFPA 101, 38.2.1.5. Delete the section and all subsections. (134) NFPA 101, 38.2.4.4(3)(a). After the word "stories," insert ", and shall not have any openings into the stair from other stories." (135) NFPA 101, 38.3.1.1(3). Delete the phrase "and the number of contiguous stories shall be unlimited." (136) NFPA 101, 40.2.1.3 and 42.2.1.3. Delete. (137) NFPA 101, 42.3.4.1.2 and 42.3.4.1.3. After the word "occupancies," insert "less than 3 stories." (138) NFPA 101, 42.8.2.2.3.2. Add the following: "Stairway Identification in accordance with 7.2.2.5.4 shall be provided." (139) NFPA 101, 42.8.3.4.1.1 and 42.8.3.4.1.3. after the word "structures," insert "less than three stories and." (140) NFPA 101, 42.8.3.4.3.1. Delete all text after the word "shall" and replace with "sound a general evacuation alarm in accordance with 9.6.3.6 and provide emergency forces notification in accordance with 9.6.4."
(Ord. No. O-03-26, 2-2-26)
Ask a question about Gaithersburg law
Corpus searches the Gaithersburg sections it holds and shows the ones that match, with their citations. Free, no sign-in.