§ 11-15 — Amendments and modifications to the NFPA codes governing fire protection systems and fireworks display

Code of the City of Gaithersburg, Maryland (Codified through Ordinance No. O-08-26, adopted September 8, 2026. (Supp. No. 52)) · Gaithersburg City Code § 11-15

Corpus is an independent public-information project, not the official City of Gaithersburg website. Stable reference: corpuslaw.us/code/a54c09cd-a632-449e-93d9-6b2caef7e87e

Sec. 11-15. - Amendments and modifications to the NFPA codes governing fire protection systems and fireworks display.

The Standard for the Installations of Sprinkler Systems (NFPA 13), 2022 Edition, the Standard for the Installation of Sprinkler Systems in One- and Two-family Dwellings and Manufactured Homes (NFPA 13D), 2022 Edition, the Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies (NFPA 13R), 2022 Edition, the Standard for the Installation of Standpipe and Hose Systems (NFPA 14), 2024 Edition, the Standard for the Installation of Stationary Pumps for Fire Protection (NFPA 20), 2022 Edition, the National Fire Alarm and Signaling Code® (NFPA 72®), 2022 Edition, the Standard for Smoke Control Systems (NFPA 92), 2022 Edition, the Standard for Ventilation Control and Fire Protection of Commercial Cooking Operations (NFPA 96), 2024 Edition, and the Code for Fireworks Display (NFPA 1123), 2021 Edition, are modified as follows: (1) NFPA 13, 5.2.2.2. Add the following: "Pressure and flow availability as determined by WSSC Hydraulic Information Sheet shall be used for new taps. Pressure and flow availability for existing taps shall be determined by interior flow test. In any case, the supply information shall be corrected for the low hydraulic gradient." (2) NFPA 13, 5.2.3. Add the following: "Booster pumps and pump/tank supplies shall only be utilized where it has been demonstrated that the public water supply is inadequate." (3) NFPA 13, 6.10.2.1.1. Add the following: "Flushing operation shall be witnessed by City of Gaithersburg Fire Marshal's Office." (4) NFPA 13, 7.2.3.2. Add the following: "Special sprinklers shall be installed where required by the City of Gaithersburg Fire Marshal." (5) NFPA 13, 9.2.5.1. After the word "motels", insert "where the least dimension of the closet does not exceed 36 inches, and." (6) NFPA 13, 9.3.4.2.3.1. Add the following: "Means of blocking off the space shall be a wall or other means approved by the City of Gaithersburg Fire Marshal." (7) NFPA 13, 9.3.11. Add the following: "New drop-out ceilings are prohibited." (8) NFPA 13, 9.3.19.2. Add the following: "This includes porte-cocheres, canopies and roofs over areas with vehicle access, except those over drive-up windows." (9) NFPA 13, 9.4.1.4. Replace the phrase "prior to the fittings being cemented in place" with "until after the hydrostatic test has been passed by the city of Gaithersburg Fire Marshal's Office." (10) NFPA 13, 9.4.2.5(12). Add new subparagraph 9.4.2.5(12) to read as follows: "(12) Intermediate-temperature classification sprinklers shall be installed in furnace rooms and laundry rooms located within dwelling units where such rooms are less than 500 cubic feet total volume." (11) NFPA 13, 12.1.1. Replace the phrase "in dwelling units and their adjoining corridors" with "to be used in cells and dwelling units in Detention and Correctional occupancies and corridors serving dwelling units, and shall be used in all dwelling units in all other occupancies" (12) NFPA 13, 16.3.12.1. After the word "ceiling" insert "and in any speculative areas subject to tenant changes, minimum one (1) inch outlets shall be provided." (13) NFPA 13, 16.3.12.2. Delete. (14) NFPA 13, 16.4.1.6. Add new subsection 16.4.1.6 to read as follows: "16.4.1.6 Where water-filled piping and/or supply mains are installed in an unoccupied or inhabitable space that relies on heating to maintain the sprinkler piping at the required temperatures, the City Fire Marshal shall have the authority to require an approved method of temperature supervision to ensure the space is maintained at required temperatures." (15) NFPA 13, 16.5. Delete the text and replace with the following: "Protection of Piping Subject to Mechanical Damage. Sprinkler system piping, risers, or drain piping installed in parking garages or other locations subject to vehicular or mechanical damage must be protected by bollards, concrete barriers, or other substantial approved means." (16) NFPA 13, 16.9.3.1.4. Add new subsection 16.9.3.1.4 to read as follows: "16.9.3.1.4 Floor control valve assemblies shall be provided as required by 16.9.10, as amended by the City Fire Code." (17) NFPA 13, 16.9.10.1. Replace the phrase "Multistory buildings exceeding two stories in height" with "Where a sprinkler system serves more than one level, each level" and add the following exceptions: "Exception 1: In buildings not exceeding three floors and 3,000 square feet per floor. Exception 2: Unoccupied and unused attics may be zoned with the level below. Exception 3: Mezzanines not exceeding 3,000 square feet in area. Exception 4: Detention and correctional facilities." (18) NFPA 13, 16.9.10.2 and 16.9.10.3. Delete. (19) NFPA 13, 16.11.2.1. Add the following: "Where a sprinkler system is required to activate a fire alarm system and separate valves for each level are required, the sprinkler system shall have a separate and distinct water flow detecting device for each floor and zone." (20) NFPA 13, 16.12.3.1.3. Add the following: "For all other systems, the number of 2½-inch inlets provided shall be as follows: System Demand (gpm) | No. of inlets Up to 749 | 2 750-999 | 3 1000 and above | 4 (21) NFPA 13, 16.12.5.1.3. Add new subsection 16.12.5.1.3 to read as follows: "16.12.5.1.3 Multiple connections for the same building shall be interconnected." (22) NFPA 13, 16.12.5.7.1. Add new subsection 16.12.5.7.1 to read as follows: "16.12.5.7.1 Fire department connections shall be located within 100 feet of a free standing (not wall type) hydrant, measured along a path accessible by walking. Measurement shall be around all obstructions, including parking spaces, fences, and landscaping." (23) NFPA 13, 19.1.1. Add the following: "Calculations for new systems or new portions of systems shall meet the following criteria: (1) Highest hazard and most demanding use allowed by building construction permit or property zoning. (2) Storage use: Available storage height and configuration which produces the greatest demand. (3) New speculative spaces subject to tenant changes shall not use grid systems or extended coverage sprinklers, and design cannot use small room or room design method. (4) All uses: Unless otherwise specifically permitted by the City Fire Marshal, all hydraulic calculations must have a minimum safety factor of 20% of the system demand pressure, or 5 psi, whichever is greater. For systems without a pump, the safety factor is based on the demand pressure only at the supply point. For systems with a pump, the safety factor is based on both the demand pressure and demand flow at the pump discharge. All design options, except grids, shall be explored. Owner occupied buildings may use a lower safety factor if a pump would be necessary to achieve the 20%." (24) NFPA 13, 19.3.1.4. Add the following: "only for systems where the originally approved design was with a discharge less than 0.1 gpm/ft²." (25) NFPA 13, 28.2.4.8.1. Add the following exception: "Exception to (5): When fitting equivalent lengths from manufacturer's published tables are used instead of equivalent lengths from Table 28.2.3.1.1, all fitting equivalent lengths in the manufacturer's chart must be accounted for in the calculations, including equivalent lengths for straight-through flow in tee or cross fittings." (26) NFPA 13, 28.2.4.8.1. Add new subparagraph 28.2.4.8.1(14) to read as follows: "(14) Where listed nonmetallic pipe is installed, and manufacturer's friction loss tables are used, the "worst case" table of all compatible manufacturers' products must be used, unless the installed fittings have distinctive manufacturer's identification markings." (27) NFPA 13, 29.2.1.4. After the phrase "testing with water," insert "for metallic pipe systems" and add the following "For systems with nonmetallic pipe, when temperatures are below 40 degrees F, the building must be heated to keep system piping to at least 40 degrees F, or a listed antifreeze must be used for the hydrostatic test of the system piping." (28) NFPA 13D, 5.2.3.2. Add the following: "Spray foam insulation and/or sealants and other construction products shall not be applied in direct contact with CPVC sprinkler piping unless the product has been documented as being compatible with CPVC sprinkler pipe." (29) NFPA 13D, 6.2(1). Add the following: "Pressure availability as determined by WSSC Low Hydraulic Gradient shall be used. Booster pumps and pump/tank supplies may only be used where it is demonstrated that the public water supply is inadequate to meet sprinkler demand." (30) NFPA 13D, 6.2.3.1. Replace the phrase "be permitted to serve" with "also control." (31) NFPA 13D, 7.1.2. After the word "unless," insert "fed by a tank and." (32) NFPA 13D, 7.2.1. Add the following: "Drain shall be downstream of any pump." (33) NFPA 13D, 7.5.6.3(3). Add the following: "Sprinklers of other than ordinary temperature rating shall not be installed unless listed coverage cannot be met with sprinklers outside of the prescribed distance from the heat source." (34) NFPA 13D, 7.5.6.3(6). Add new subparagraph 7.5.6.3(6) as follows: "(6) Intermediate-temperature classification sprinklers shall be installed in furnace rooms and laundry rooms that are less than 500 cubic feet total volume." (35) NFPA 13D, 7.5.9. Replace the phrase "prior to the fittings being cemented in place" with "until after the hydrostatic test has been passed by the city." (36) NFPA 13D, 7.5.10. Add new subsection 7.5.10 to read as follows: "7.5.10 Concealed Sprinklers. Concealed sprinklers shall not have any spray foam applied to the sprinkler assembly, and the cover plates shall not have any caulk, sealant, paint, glue, or any other product that may adversely affect sprinkler operation applied to the cover plate or between the cover plate and the ceiling." (37) NFPA 13D, 8.2.7. After the title "Closets and Compartments" and before the first sentence, insert "Sprinklers in closets shall not be located directly above shelves.", and replace the phrase "including those" with the word "and." (38) NFPA 13D, 8.3.3(3). Add new subparagraph 8.3.3(3) to read as follows: "(3) The shortest dimension does not exceed 36 inches." (39) NFPA 13D, 9.1.1. Add the following: "Wet pipe shall not be installed in floor spaces above unconditioned or non-habitable spaces such as garages, crawlspaces, and similar." (40) NFPA 13D, 9.2. Add the following: "Antifreeze Systems shall not be installed unless specifically permitted by the City Fire Marshal." (41) NFPA 13D, 10.4.4(8)(d). Add new subsection 10.4.4(8)(d) to read as follows: "(d) Where nonmetallic pipe is installed, and manufacturer's fitting equivalent length tables are used, the "worst case" table of all compatible manufacturers' products must be used, unless the installed fittings have distinctive manufacturer's identification markings." (42) NFPA 13D, 10.4.10. Add new subsection 10.4.10 to read as follows: "10.4.10 All calculations shall include a minimum safety factor of the greater of 10% of the demand pressure or 5 psi, to account for minor field changes, unless a booster pump is necessary to obtain this safety factor." (43) NFPA 13D, 11.2.1.4. Replace the phrase "be permitted to" with "not" and delete the phrase "or plugs." (44) NFPA 13D, 11.2.1.5. Add new subsection 11.2.1.5 to read as follows: "11.2.1.5 When temperatures are below 40 degrees F, the building must be heated to keep system piping to at least 40 degrees F, or a listed antifreeze must be used for the hydrostatic test of the system piping." (45) NFPA 13R, 1.1. After the phrase "grade plane", insert "or the level of fire department access required by Chapter 18 of NFPA 1, whichever is lower" and add the following: "Maximum height shall be measured to the highest peak of the roof." (46) NFPA 13R, 3.3.7. Delete the text and replace with the following: "Grade Plane. For the purposes of this standard, grade plane shall be defined in NFPA 101, as amended by the City Fire Code." (47) NFPA 13R, 5.2.3. Add the following: "Spray foam insulation and/or sealants and other construction products shall not be applied in direct contact with CPVC sprinkler piping unless the product has been documented as being compatible with the CPVC sprinkler pipe installed." (48) NFPA 13R, 5.4.2(1). After the word "system", insert ", where specifically permitted by the City Fire Marshal, and." (49) NFPA 13R, 6.2.1.1. Delete the phrase "6.2.1.3 or." (50) NFPA 13R, 6.2.1.3, 6.2.1.3.1, and 6.2.1.3.2. Delete. (51) NFPA 13R, 6.2.3.1. Add the following: "Sprinklers of other than ordinary temperature rating shall not be installed unless listed coverage cannot be met with sprinklers outside of the prescribed distance from the heat source." (52) NFPA 13R, 6.2.3.3.4. After the phrase "clothes dryers," insert "or in furnace rooms or laundry rooms that are less than 500 cubic feet total volume." (53) NFPA 13R, 6.4.6.3.2. After the title "Within Closets and Compartments," and before the first sentence, insert the following: "Sprinklers shall not be located directly above shelves.", and replace the phrase "including those" with the word "and." (54) NFPA 13R, 6.7.1.1. Replace the phrase "prior to the fittings being cemented in place" with "until after the hydrostatic test has been passed by the city." (55) NFPA 13R, 6.7.2.1.2. Add new subsection 6.7.2.1.2 to read as follows: "6.7.2.1.2 Where sprinkler piping and/or supply mains are installed in unoccupied or inhabitable spaces that rely on heating to maintain the sprinkler piping at the required temperatures, the City Fire Marshal shall have the authority to require an approved method of supervision to ensure the space is maintained at required temperatures." (56) NFPA 13R, 6.8.2. Delete the text and replace with the following: "On systems protecting more than one dwelling unit, the system piping may have a separate control valve installed if the valve is supervised Add "electronically only," in the open position by central station monitoring." (57) NFPA 13R, 6.11.2. Add the following: "The fire department connection shall be located on a street front and shall be mounted such that it is 18 to 48 inches from the centerline of the inlet to finished grade." (58) NFPA 13R, 6.11.5.2. Add new subsection 6.11.5.2 to read as follows: "6.11.5.2 The piping between the fire department connection and the system main shall not have a smaller diameter than the main system riser diameter." (59) NFPA 13R, 6.15. Delete. (60) NFPA 13R, 8.2.1. After the phrase "NFPA 13, add the following: "as amended by the City Fire Code, and all calculations shall include a minimum safety factor of the greater of 10% of the system demand pressure or 5 psi, to account for minor field changes, unless a booster pump would be necessary to obtain this safety factor." (61) NFPA 13R, 9.6.2. Delete all text after the phrase "volume and pressure" and replace with "availability, as determined by WSSC, shall be used, and shall be adjusted for the low hydraulic gradient." (62) NFPA 13R, 9.7.2. Add the following: "Booster pumps or pump/tank assemblies as part of the sprinkler system water supply shall only be used where it is demonstrated that the public water supply is inadequate." (63) NFPA 13R, 10.2.2.3. Add new subsection 10.2.2.3 to read as follows: "10.2.2.3 When temperatures are below 40 degrees F, the building must be heated to keep system piping to at least 40 degrees F, or a listed antifreeze must be used for the hydrostatic test of the system piping." (64) NFPA 14, 7.8.3 Add the following: "Caps shall be secured to the standpipe riser with chains." (65) NFPA 14, 5.1.2. Delete the text and replace with the following: "Unless otherwise approved by the City Fire Marshal, standpipe systems shall comply with the following: (1) Standpipe systems in unheated areas shall be automatic dry type. (2) Standpipe systems in detached open parking garages may be manual dry type, if the piping is air supervised for breaks or open valves in accordance with 6.1.1. (3) All other standpipe systems shall be automatic wet type. (4) Occupant use of houses is prohibited in new or existing buildings. (5) New standpipe systems shall be Class I only." (66) NFPA 14, 5.4.1.1. Delete the text and replace with the following: "Class I standpipe systems shall be of the types as specified in 5.1.2 as amended by the City Fire Code." (67) NFPA 14, 9.9.5.3. After the word "services", insert "a section of a building, or." (68) NFPA 14.9.9.5.4.1 Add new subsection 9.9.5.4.1 to read as follows: "9.9.5.4.1 Measurement shall be along a path accessible by walking, around all obstructions, including parking spaces, fences, and landscaping. In parking areas, measurement cannot pass through or between parking spaces unless a minimum 44-inch-wide path is provided and defined by curbs, bollards, or other method approved by the City Fire Marshal." (69) The location of additional hose connections shall be approved by the AHJ. (70) NFPA 14, 9.5.2.4.4. After the word "location", insert "and measurement" and after the word "AHJ" add "and shall comply with the following: (1) Measurement shall be parallel or at right angles to walls. (2) Measurement in parking areas shall be around all designated parking spaces. (3) Supplemental hose valves outside the stairs shall not be located within tenant spaces, unless those reach requirements cannot be met by placement of valves in public corridors or by use of wall hydrants for spaces opening to the exterior. Hose valve locations shall be marked by the placement of signs, the striping of columns, or other approved methods. (4) Where supplemental hose valves are provided in parking areas, valves must be located adjacent to drive lanes or provided 44-inch-wide access aisles to the valve, defined by curbs, railings, bollards or other approved means to prevent vehicles from parking in the access aisle." (71) NFPA 14, 10.2.6.1. Add the following exceptions: "Exception 1: In high-rise buildings, where booster pumps are necessary to produce the required residual pressures, pumps and piping systems may be sized to provide for the demand of the hydraulically most remote hose station, or the sprinkler system demand, whichever is greater, but the standpipe system shall also be sized to provide the required flow and pressure for all those stations required to be flowing, when supplied by 150 psi at the fire department connection(s). Two sets of calculations will, therefore, be required under this exception. Exception 2: In existing buildings, after shell final inspections have been approved, hose valves added to meet travel distance requirements due to excessive travel distance created by tenant modifications may be supplied by 3-inch pipe without recalculation." (72) NFPA 14, 10.2.6.1.2. After the word "systems," insert "and systems in buildings that are not high-rise," and add the following ", assuming 150 psi available supply." (73) NFPA 14, 5.3.2. Add the following: "For new systems required to have an automatic or semiautomatic water supply, the water flow rate and pressure must be based on a WSSC Hydraulic Information Sheet when the system is supplied by a new underground fire main. For new systems supplied by an existing underground fire main, the water supply must be based on a flow test of the existing main, with adjustment for WSSC Low Hydraulic Gradient." (74) NFPA 20, 4.2.4. Add the following: "Fire pump installations, including the pump, driver, or controller, shall not be permitted to be installed in below-ground areas such as vaults or pits unless specifically allowed by the City Fire Marshal." (75) NFPA 20, 4.16.6.4. Add the following: "Eccentric reducers shall be installed with the flat side on the bottom when fed from above." (76) NFPA 72, 7.2.1. Replace the phrase "Where documentation is required by the authority having jurisdiction, the" with the word "The." (77) NFPA 72, 7.3.1, 7.4.1, 7.5.1, and 7.8.1.1. Delete the word "only" and, after the phrase "required by," insert "the City Fire Marshal;", (78) NFPA 72, 10.5.2.1. Add the following: "All such work shall be performed under the supervision of an electrician with a valid City Electrical License." (79) NFPA 72, 10.18.1.2. Delete the text and replace with the following: "An annunciator with the following features is required when the building is greater than one story, over 22,500 square feet in area per floor, or has more than one type of alarm initiating device: (1) Annunciator shall have a visible signal for each different floor, zone, and device type. Floor designations shall match those used in elevators and stairways. (2) A lamp type annunciator shall have a lamp test switch unless the annunciator circuits are supervised." (80) NFPA 72, 10.18.3.2. Delete all text after the word "located" and replace with "at, and visible from, the main fire department entrance, or other location approved by the City Fire Marshal." (81) NFPA 72, 10.18.5.1. Add the following: "Floors exceeding 22,500 square feet in area or 300 linear feet shall be separated into multiple zones not to exceed those parameters." (82) NFPA 72, 10.18.5.3. Delete the text and replace with the following: "If two or more buildings are controlled by one alarm system, an annunciator shall be installed in each building, and each annunciator shall indicate the building of alarm origination." (83) NFPA 72, 10.18.5.4. Add new subsection 10.18.5.4 to read as follows: "10.18.5.4 If two or more zones per floor are required, a graphic outline incorporated into or adjacent to the annunciator shall be provided showing the building address, building outline, exterior entrances, zone boundaries, "you are here" notation, north compass arrow, all stairways, stairway identification, the floors served by each stairway, stairways that have roof access, all elevators, elevator identification, the floors served by each elevator, elevator machine rooms, emergency generator, main utility shutoffs, fire alarm control panel, fire pump, all standpipe risers, adjacent, street(s), and fire department connections." (84) NFPA 72, 17.7.1.7. Add the following: "Detectors located at the top of shafts and stairs shall only sound a supervisory signal unless a confirmation or verification feature is provided to minimize unwanted alarms. The location shall be identified at the annunciator or fire alarm control panel." (85) NFPA 72, 17.7.1.8. Add the following: "Where automatic detection is required within environments not suitable for smoke detectors, rate of rise detectors, rate compensated detectors, or other detection as approved by the City Fire Marshal shall be installed." (86) NFPA 72, 17.7.6.4.2. Add the following: "Activation of duct smoke detectors shall sound an audible signal in a normally occupied area or through the building fire alarm system. If connected to the building alarm system, the signal shall initiate a supervisory signal only and shall not initiate the building evacuation alarm." (87) NFPA 72, 17.13.4. Add new subsection 17.13.4 to read as follows: "17.13.4 Standpipe or main water flow indicators, where provided, shall initiate a supervisory signal only." (88) NFPA 72, 17.15.9. Change "17.15.9.6" to "17.15.9.7." (89) NFPA 72, 17.15.9.7. Add new subsection 17.15.9.7 to read as follows: "17.15.9.7 Approved '9-1-1' instruction signs shall be permanently affixed and maintained at each manual fire alarm box, unless the fire alarm is monitored by a UL listed central station." (90) NFPA 72, 18.4.2.5. Add new subsection 18.4.2.5 to read as follows: "18.4.2.5 Audible alarm notification appliances within the same area or room must all have the same audible characteristics." (91) NFPA 72, 18.4.4.1. Add the following: "and with all intervening doors closed." (92) NFPA 72, 23.8.2.9.2. After the phrase "individually at each control unit," insert "for only up to two control units." (93) NFPA 72, 23.8.5.4.5. After the word "notification," insert "or activation of a required extinguishing system." (94) NFPA 72, 29.8.1.1.1. Add new subparagraph 29.8.1.1.1 to read as follows: "29.8.1.1.1 For the rooms addressed in 29.8.1.1(1), enclosed rooms such as dens, libraries, studies, or sitting rooms which could be used as a temporary sleeping area shall be treated as sleeping rooms." (95) NFPA 92, 7.1(3). Add new subparagraph 7.1(3) to read as follows: "(3) System shop drawings for submittal to the AHJ." (96) NFPA 92, 7.2. Add new subsection 7.4 to read as follows: "7.4 Shop Drawing Submittals. Shop drawings shall be prepared and submitted to the City of Gaithersburg for review and a Fire Protection Permit shall be obtained prior to beginning installation. Shop drawings shall include the following information: (1) Plans and specifications (2) Engineering calculations and/or computer model (3) Floor plans (4) System diagram and details (5) Sequence of operations and control layout (6) Preliminary test procedures (7) Acceptance test procedures (8) Pass/fail criteria" (97) NFPA 96, 1.1.6. Delete the text and replace with the following: "In day-care centers and business occupancies doing food warming only, Home Economic classrooms in Educational Occupancies, or in existing structures that were originally constructed as single family dwellings and have been converted to Lodging or Rooming Houses or small Board and Care facilities, protection may consist of the following: (1) A listed and approved recirculating residential ventilation hood with range top extinguishing system installed in accordance with the manufacturer's specifications (2) For residential ranges with recirculating ventilation hoods in buildings equipped with approved automatic sprinkler protection throughout, the sprinkler system may be considered to provide surface protection." (98) NFPA 96, 4.7. Replace the phrase "If required by the authority having jurisdiction, notification" with "Notification" and add "Alteration of any extinguishing system requires a permit to be obtained from the City of Gaithersburg before beginning alterations." (99) NFPA 96, 10.8.1. Replace the phrase "Where required, complete drawings" with "Manufacturer's specifications, and complete shop drawings," and add the following: "Shop drawings shall include all information as required in 4.6.2 and all the following: (1) Diagram of the area and equipment to be protected, including the dimensions of the hood and duct and all surfaces and appliances. (2) Manufacturer and model number the system(s). (3) Diagram of the system piping and all component parts, to include: (a) Piping type (b) Sizes and lengths of all pipes (c) Model numbers and locations (mounting heights) of nozzles (d) Locations and temperature ratings of fusible links (4) A floor plan of the kitchen layout (to scale, or dimensioned) showing the following: (a) Location of system canister(s)/cabinet and canister sizes (b) Location of manual means of activation (c) Location and identity of any auxiliary equipment, including gas and power (electric) shutoff." (100) NFPA 1123, 5.1.3.1 and Table 5.1.3.1. In 5.1.3.1, change "70" to "100" and in Table 5.1.3.1, under "Minimum Secured Diameter" change the numbers to equal the diameter of the mortar size multiplied by 200, and, under "Vertical Mortars," change the numbers to equal the diameter of the mortar size multiplied by 100.

(Ord. No. O-03-26, 2-2-26)