Sec. 5-253. - Same—Exceptions and supplemental standards.

The following apply to all installations, repairs, and alterations of plumbing and subject to the provisions of this article, anything to the contrary contained in the ICC International Plumbing Code, 2021 Edition or the International Residential Code, 2021 Edition, notwithstanding. It is the intent of the City to provide supplemental regulations and exceptions to the ICC International Plumbing Code, 2021 Edition, and the International Residential Code, 2021 Edition. (1) Fittings. No changes in direction in drainage piping shall be made by the use of short sweep bends without specific approval of the administrative authority having been first had and obtained; (2) Depth of building sewer and water service (outside of buildings). Sewers and water servicing pipe shall be installed below the recorded frost penetration, but in no case less than two (2) feet, two (2) inches for sewer and two (2) feet, six (6) inches for water piping below grade; (3) Water heating equipment. A shutoff valve shall be provided in the cold water branch line to each water storage tank or each water heater. The shutoff valve so provided shall be protected from accidental closing and tampering; (4) Sub-drains and storm sewers. No building wall sub-drains, areaway, driveway or roof leaders shall be connected to the sanitary sewer. Such drain systems shall be separately connected to an independent dry well drainage system, to a storm sewerage system, or drained by some other method approved by the administrative authority; (5) Building sewer and sanitary drainage system. The administrative authority may require the use of cast-iron pipe for the installation of the sanitary drainage system and the building sewer if unstable soil or other conditions warrant such use. A cleanout and brass plug with a countersunk head shall be installed as near the property line as possible. A #12 copper wire, with the end accessible at the cleanout, shall be taped to all nonmetallic sewer laterals to provide a means of locating the lateral by a metal detector or other device. An approved adaptor shall be used to provide connection between piping of different size, weight, and material; (6) Water service pipe. Water service pipe installed underground between the City's main and the property line shall be type "K" copper tubing with flare fittings only for sizes up to and including two (2) inches. (7) Fixture shutoff valves. Each plumbing fixture shall be equipped with an accessible shutoff valve to interrupt water supply for servicing. (8) Water-cooled air conditioning, refrigeration machinery and compressor installations. a. Rate and use of cooling water. All water-cooled air conditioning, refrigeration machinery and compressor installations using water from the public water supply for cooling purposes or discharging water into the City's sewerage or drainage systems, shall be installed in accordance with these regulations, and shall be subject to the City's inspection and approval. A written permit will be required for each installation. Such installations will be permitted to take water from the City's system at a rate not greater than 0.08 gallon per minute per ton of refrigeration. An approved type of economizer or cooling tower shall be installed if necessary to meet this limitation; b. Rating of water-cooled machinery. A ton of refrigeration shall be considered as the cooling effect of two hundred (200) BTU's per minute. The standard rating of refrigeration machines is expressed as the number of tons of refrigeration it can produce under certain conditions. For compressors, one (1) horsepower of rated capacity will be considered equivalent to one (1) ton of refrigeration; c. Disposal of cooling water. Water from any such above installation, whether or not the water is taken from the City's system, shall not be discharged into the City's sanitary sewerage system at a rate greater than 0.08 gallon per minute per ton of refrigeration; d. Cross-connections. All such installations shall be installed without cross-connections and with an approved means of backflow prevention installed; e. Installation to conform. All water-cooled air conditioning equipment, refrigeration machinery and compressor installations using water from, or discharging water into, the City's system, whether or not installed prior to the adoption of this section, where required, shall be modified to bring them into conformance with the provisions of these regulations; f. Penalty for nonconformance. Properties in which water-cooled air conditioning equipment, refrigeration machinery, and compressor installations are made contrary to the provisions of this section and which installations are not promptly modified as directed, will be disconnected from the City's system until the requirements of this section are complied with.

(Ord. No. 11-15, § 11, 6-1-15; Ord. No. 22-19, § 11, 9-9-19; Ord. No. 6-24, § I, 5-20-24)

Ask a question about Rockville law

Corpus searches the Rockville sections it holds and shows the ones that match, with their citations. Free, no sign-in.