§ 16-2.2 — Building sewers and connections
Revised Code of Ordinances, City of Old Town Maine (eCode360 publication OL4196 current through legislation adopted 2025-12-01 (imported 2026-11-16)) · Revised Code of Ordinances, City of Old Town Maine § 16-2.2
Corpus is an independent public-information project, not the official City of Old Town website. Stable reference: corpuslaw.us/code/15c7c367-bd01-487c-afd5-8af8812f485c
§ 16-2.2: Building sewers and connections.
(a) No person(s) shall uncover, make any connections with or opening into, use, alter, or disturb any public sewer or appurtenance thereof without first obtaining written permission from the Superintendent. (b) Permits. (1) There shall be two classes of building sewer permits: a. For residential and commercial service producing only domestic wastewater; and b. For service to establishments producing industrial wastes. (2) For residential and commercial services, the owner(s) or his agent shall make application on a special form furnished by the City at least 30 days prior to said service connection. For an establishment discharging industrial wastes, the application shall be made at least 60 days prior to said service connection. (3) The permit application shall be supplemented by any plans, specifications, or other information (including pollution prevention studies) considered pertinent in the judgment of the Superintendent. (4) A permit and inspection fee in accordance with the provisions of applicable City requirements shall be paid to the City at the time the application is filed. (c) All costs and expenses incidental to the installation and connection of the building sewer shall be borne by the owner(s). The owner(s) shall indemnify the City from any loss or damage that may directly or indirectly be occasioned by the installation of the building sewer. (d) A separate and independent building sewer shall be provided for every building, except where one building stands at the rear of another on an interior lot and no private sewer is available or can be constructed to the rear building through an adjoining alley, court, yard, or driveway. In such cases, the front building sewer may be extended to the rear building and the whole considered as one building sewer, but the City does not and will not assume any obligation or responsibility for damage caused by or resulting from any such single connection. (e) Existing building sewers may be used in connection with new buildings only when they are found, on examination and test by the Superintendent, to meet all requirements of this Part. (f) The size, slope, alignment, materials of construction of a building sewer, and the methods to be used in excavating, placing of the pipe, jointing, testing, and backfilling the trench shall all conform to the requirements of the building and plumbing code or other applicable rules and regulations of the City and DEP rules. In the absence of code provisions or in amplification thereof, the materials and procedures set forth in appropriate specifications of the American Society for Testing and Materials (ASTM) and Water Environment Federation (WEF) Manual of Practice No. FD-5 shall apply. (g) During construction of a new sanitary sewer, the City may construct the service connections for existing buildings to the property line or the edge of a right-of-way. Construction of the building sewer, including connection to the structures served, shall be the responsibility of the owner of the improved property to be connected; and such owner shall indemnify and save harmless the City, its officers, and agents from all loss or damage that may result, directly or indirectly, due to the construction of a building sewer on his premises or its connection to the service connection. The owner shall thereafter be obligated to pay all costs and expenses of operation, repair and maintenance, and of reconstruction, if needed, of the building sewer and service connection. (h) Whenever possible, the building sewer shall be brought to the building at an elevation below the basement floor. In all buildings in which any building drain is too low to permit gravity flow to the public sewer, sewage conveyed by such building drain shall be lifted by an approved means and discharged to the building sewer at the owner's expense. (i) No person(s) shall make connection of sump outlets, sump pumps, floor drains, roof downspouts, interior or exterior foundation drains, areaway drains, sumps or sump pumps, floor drains, or other sources of surface runoff, groundwater, or any other source of nonpolluted water to a building sewer or building drain that in turn is connected directly or indirectly to a public sanitary sewer. (j) No person shall obstruct the free flow of air through any drain or soil pipe. (k) The connection of the building sewer into the public sewer shall conform to the requirements of the building and plumbing code or other applicable rules and regulations of the City/Town, or the procedures set forth in appropriate specifications of the ASTM and the WEF Manual of Practice No. FD-5. All such connections shall be made gastight and watertight and verified by proper testing. Any deviation from the prescribed procedures and materials must be approved by the Superintendent before installation. (l) The applicant for the building sewer permit shall notify the Superintendent when the building sewer is ready for inspection and connection to the public sewer. Such notice shall be provided not less than 48 hours in advance of the time any connection is to be made to any public sewer. The connection and testing shall be made under the supervision of the Superintendent or his representative. This requirement shall also apply to repairs or alterations to building connections, drains or pipes thereto. (m) Suitable provisions shall be made at the point of connection for testing, which responsibility shall rest with the holder of the sewer connection permit. The City reserves the right to perform an internal television inspection of the building sewer. (n) No building sewer shall be covered until it has been inspected and approved by the Superintendent. If any part of building sewer is covered before being inspected and approved, it shall be uncovered for inspection at the cost and expense of the owner of the improved property to be connected to the public sewer. (o) The Superintendent shall maintain a record of all connections made to public sewers and drains under this Part and all repairs and alterations made to building connections or drains connected to or discharging into public sewers and drains of the City or intended to so discharge. All persons concerned shall assist the Superintendent in securing the data needed for such records. (p) All excavations for building sewer installation shall be adequately guarded with barricades and lights so as to protect the public from hazard. Streets, sidewalks, parkways, and other public property disturbed in the course of the work shall be restored in a manner satisfactory to the City at the expense of the owner. (q) Proposed new discharges from residential or commercial sources involving loadings exceeding 5,000 gallons per day, any new industrial discharge, or any alteration in either flow or waste characteristics of existing industrial wastes that are being discharged into the POTW must be approved by the DEP. Such approvals shall be obtained in accordance with § 16-6.2 of this Part. (r) The connection of the building sewer to the public sewer shall be made at the wye branch or its equivalent. When connecting a four-inch-diameter building sewer to any public sewer eight inches in diameter or less, or when connecting a six-inch-diameter building sewer to any public sewer 12 inches in diameter or less, a wye branch must be installed in a location specified by the Superintendent. For new construction, a six-inch-diameter building sewer and wye connection must be used. Where the public sewer has greater than the maximum diameter for installation of a wye branch as specified above or no properly located wye branch is available, a neat hole may be cut into the upper quadrant of the public sewer to receive the building sewer, with entry to be made in the downstream direction at an angle of approximately 45°, again in a location specified by the Superintendent. A properly sized wye saddle shall be inserted into the hole so as not to extend past the inner surface of the public sewer. A smooth, neat joint shall be made and the connection made secure and watertight by encasement in concrete or as otherwise approved. Special fittings may be used for the connection only when approved by the Superintendent. (s) For any building sewer serving a school, hospital or similar institution or public building, or serving a complex of commercial or industrial buildings, or which, in the opinion of the Superintendent, will receive sewage or industrial wastes of such volume or character that frequent maintenance of said building sewer is anticipated, such building sewer shall be connected to the public sewer through a manhole, the cost of which shall be borne by the property owner. If required, a new manhole shall be installed, at no expense to the City, in the public sewer, and the location of this manhole and the building sewer connection to it or to an existing manhole shall be as specified by the Superintendent. (t) Each and every plumber, contractor or excavator, or other person, firm or corporation, other than the property owner himself, will be required to secure a license for sewer work, issued by the City Clerk, before he will be permitted to do any work in the City insofar as this chapter is concerned. The initial fee shall be as per City policy, renewable annually for a fee also as per City policy. (u) As part of the application for a license to do work in the City, the applicant may be required to present a license bond written by an indemnity or bonding company lawfully doing business in the State of Maine in a form provided by the City Council or delegated authority. (v) If, in the opinion of the City Council, the work performed by the contractor within the City violates the provisions of this chapter or any other ordinance of the City, or if the contractor's work is, in the opinion of the City Council, substandard, then in that event, the City Council or delegated authority may revoke the license for the contractor to do work in the City. (w) A contractor must present a certificate showing proof of liability insurance before a permit will be issued for construction of building sewers, sewer extensions or private sewage disposal. (x) Should the City determine that any private building sewer is discharging unpolluted wastewater in violation of the provisions of this Part, the City reserves the right to install a new building sewer, including a separate sewer for conveyance of the unpolluted wastewater into the City stormwater system on the user's property to within five feet of the foundation, with the proper temporary construction easement from the user. The City also reserves the right to charge the user for all costs associated with the installation of the new building sewers. (y) All building sewers shall be owned by the property owner from the building to the main sewer line.
[ Ord. of 5-5-2008 ]
Ask a question about Old Town law
Corpus searches the Old Town sections it holds and shows the ones that match, with their citations. Free, no sign-in.
