7.5 SUPPLEMENTAL DIMENSIONAL STANDARDS

7.5.1 Corner clearance No shrub, wall, fence, sign, or pile of material higher than 3 1/2 feet above the lowest elevation at the curbline shall be permitted on a corner lot within the area of a triangle formed by a line connecting the curblines of the intersecting streets at points 25 feet from the corner, unless said obstruction is reviewed by the Public Works Authority and found not to be a traffic or public safety hazard. 7.5.2 Pedestrian passage required A. Where a nonresidential or mixed-use building exceeds 300 feet in length along a public right-of-way, and abuts two parallel frontages with pedestrian facilities, or one frontage with pedestrian facilities and a public park, or other public open space on the side of the building opposite the street frontage, a pedestrian passage is required to provide a break in the ground-floor façade and facilitate mid-block connectivity. Such passage shall meet the following standards: 1. Passages shall be designed to accommodate pedestrians and, to the extent practicable, bicyclists. Vehicular access and circulation shall not be allowed as a component of a passage. 2. Passages shall be a minimum of 30 feet in width and 20 feet in height and shall be located within the middle third of the building, measured along the frontage. 3. Ground floor uses shall be oriented toward the passage, including public entrances. 4. Ground floor façades facing into building passages in nonresidential and mixed-use buildings shall maintain a minimum transparency of 35% of the wall area of the passage. 5. Passages shall be designed to maintain views from one end through to the other. 6. Inclusion of decorative elements such as lighting installations or public art within passages is encouraged. 7. Passages shall align with the street grid or other points of access to sidewalks, public paths, parking lots, public parks or other publicly owned open space where feasible. 8. For the purposes of any build-to zone requirement, a building passage is considered part of the building façade that meets such requirement. B. Where a nonresidential or mixed-use building exceeds 300 feet in length along a public right-of-way, but does not abut two parallel frontages with pedestrian facilities as specified in (A) above, a break in the building massing is required as follows: 1. Building mass shall be recessed a minimum of 20 feet in depth for no less than 30 linear feet along the façade. 2. Such recess shall extend the full height of the building, and shall meet the following criteria: a. The recess shall be located within the middle third of the building, measured along the frontage. b. Ground floor uses shall be oriented toward the recessed area, including public entrances. c. The recessed area is subject to all transparency requirements. d. The recessed area shall be designed as public or common space including amenities such as seating areas, landscaping, lighting, decorative elements, and public art. e. For the purposes of any build-to zone requirement, a building recess meeting these standards is considered part of the building façade that meets such requirement. C. Where another means of meeting the City’s connectivity goals may be preferable to providing a pedestrian passage as specified in this subsection, the Planning Board or Planning Authority may waive these requirements and approve an alternative design. 7.5.3 Towers A. Purpose and applicability. Portions of buildings extending above a height of 125 feet shall be considered towers, and are subject to additional standards to ensure their design minimizes encroachment into view corridors, ensures adequate provision of light and air to adjacent streets, trails, and open spaces, and enhances the visual richness and aesthetic appeal of the Portland skyline. B. Stepback required 1. Portions of buildings higher than 125 feet shall be stepped back a minimum of 30 feet from any street or public open space, with the following exceptions: a. Structures subject to standards that require a stepback below 125 feet in height shall be exempt from providing additional stepback above 125 feet. This exemption applies regardless of the dimension of the required stepback at lower building heights. b. Structures that voluntarily achieve a total stepback, below 105 feet in height of 20 feet or greater from any street or public open space, with at least one stepback occurring between 35 and 65 feet in height. No individual stepback used to meet this standard shall be less than ten feet in depth. FIGURE 7-J: TOWER STEPBACK [image omitted; see the official code] 2. Structures with multiple façades abutting a street or public open space are subject to the following: a. Structures with two façades subject to the required stepback must meet the standard as established in (A) above for both façades. b. Structures with three façades subject to the required stepback must meet the standard as established in (A) above for the two longest building façades. The third façade shall either meet the standard as established in (A) above, or provide a 15 foot wide streetscape improvement area containing a public sidewalk, landscaping, and other streetscape improvements within the abutting street right-of-way and/or private property along the street frontage. c. Structures with four or more façades subject to the required stepback must meet the standard as established in (A) above for the two longest building façades. The remaining building façades shall either meet the standard as established in (A) above, or provide a 15 foot wide streetscape improvement area containing a public sidewalk, landscaping, and other streetscape improvements within the abutting street right-of-way and/or private property along the street frontages. 3. The Planning Board shall have the authority to waive one or more of the required stepbacks provided that one of the following conditions is met: a. The depth of the building lot precludes a building having an average minimum lot depth dimension of 170 feet. b. The proposed building has an architecturally significant design that is articulated to avoid a monolithic appearance and emphasizes slender, vertically-oriented proportions while employing a variety of scales, materials, fenestration, and massing to assure a rich, visually interesting experience as viewed within the context of the downtown skyline and provide visual interest and human scale at the pedestrian level. 4. In the event that the Planning Board grants a waiver for one or more of the required stepbacks, the Board may require the applicant to mitigate the impacts of the waiver by requiring any or all of the following conditions: a. Along all public street frontages and public open spaces, all buildings (regardless of height) shall maintain a pedestrian scale through the use of building elements at the street level as listed in this standard along no less than 60% of the building’s horizontal length. b. Along all public street frontages and public open space for the building(s) over 125 feet, a canopy, awning, or similar permanent architectural feature to provide pedestrian protection and wind mitigation shall be provided within the first 35 feet of height. c. The applicant shall demonstrate that building design elements and location will reasonably mitigate downdraft effects of the proposed building or buildings. C. Tower floor plates. To minimize shadow and wind impacts, loss of views, and to allow for the passage of light and air into interior spaces, those portions of a building above 125 feet in height are limited to a maximum floor plate of 10,000 square feet. FIGURE 7-K: TOWER FLOOR PLATES [image omitted; see the official code] D. Tower separation. In order to preserve view corridors and to maintain a varied skyline, the following tower separation requirements apply: 1. All portions of buildings above 125 in height shall provide a minimum of 35 feet of setback from side and rear lot lines when abutting another tower, except for towers located within a single development site. 2. Towers within a single development site shall be separated to avoid the appearance of a tall, solid block massing. 3. All portions of buildings above 125 feet in height shall be separated a minimum distance of 75 feet, measured parallel to any applicable street frontage. 4. On development sites of 500 feet or greater as measured parallel to Marginal Way, the aggregate building façade widths above 85 feet shall not exceed 50% of the total development site distance parallel to Marginal Way. Buildings over 125 feet in height that are being reviewed as separate phases shall be entitled to meet the 50% building requirement in aggregate for all such buildings over 125 feet in height, provided that view corridors are retained as each phase is built. FIGURE 7-L: TOWER SEPARATION [image omitted; see the official code] E. Architectural cap allowance 1. A tower may extend up to 40 feet above the designated height limit for the purpose of enclosing rooftop appurtenances, and providing a distinctive architectural cap that adds visual interest to the Portland skyline. This does not apply to towers in the B-3 zone located north of Cumberland Avenue. 2. No habitable floor area shall be created within the building envelope provided by an architectural cap, unless the following standards are met: a. A minimum of 50% of such habitable floor area is devoted exclusively to one or more uses open to the public, such as a restaurant, atrium, or viewing area. b. The primary design intent and expression of the architectural cap shall determine whether additional floor area is created. Such floor area should be clearly incidental to the design expression, rather than a continuation of floor plates found below the architectural cap. 7.5.4 Supplemental dimensional standards for specific structures A. Fences. In residential zones, no wall or fence within 15 feet of the street shall be more than four feet in height, unless said fence is located in the side or rear yard. B. Swimming pools. Outdoor swimming pools as accessory uses shall be subject to the following dimensional standards: 1. No swimming pool shall be sited in the front yard. 2. No part of any swimming pool shall be located closer than 10 feet from the principal structure, nor closer than 10 feet from side or rear lot lines.

Ask a question about Portland law

Corpus searches the Portland sections it holds and shows the ones that match, with their citations. Free, no sign-in.