For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 7.6 — Space and Bulk Exceptions

Code of Ordinances, City of Portland, Maine (Chapters as revised by the City Clerk, latest revision September 9, 2026 (each chapter carries its own revision date)) · Portland Code of Ordinances, Land Use Code § 7.6

Corpus is an independent public-information project, not the official City of Portland website. Stable reference: corpuslaw.us/code/2f25e0ee-eee6-4d23-9104-9a58f3d8e868

7.6 SPACE AND BULK EXCEPTIONS

7.6.1 Height A. Exceptions to minimum height requirements in any zone. Minimum height requirements in any zone shall not apply to the following: 1. Accessory building components and structures such as truck loading docks, covered parking, mechanical equipment enclosures and refrigeration units. 2. Information kiosks, ticketing booths, parking attendant booths, or bank remote teller facilities. 3. Structures accessory to parks or plazas. 4. Utility substations, including sewage collection and pumping stations, water pumping stations, transformer stations, telephone electronic equipment enclosures, and other similar structures. B. Exceptions to minimum height requirements in the B-3 zone. Minimum height provisions as depicted on the City of Portland Height Map shall not apply to: 1. Additions to buildings existing as of June 4, 2007 provided that the cumulative additions since June 4, 2007 do not exceed 10% of the building footprint on June 4, 2007, except building additions on those portions of the lot located closer to the street line than the building footprint existing as of June 4, 2007 shall not be included in this 10% limitation. 2. Buildings or building additions of less than 2,500 square feet footprint, on lots or available building sites of less than 3,000 square feet. C. Exceptions to minimum height requirements in the B-6 zone. Minimum height provisions as depicted on the B-6 Building Height Overlay and Building Envelopes map shall not apply to: 1. Buildings located in the area east of Freedom Way. 2. Parking garages. 3. Additions to buildings existing as of December 8, 2004 provided that the cumulative additions since December 8, 2004 do not exceed 25% of the building footprint on December 8, 2004, except that such restriction shall not apply to those portions of the building addition that are constructed closer to the street line than the building footprint existing as of December 8, 2004. 4. Buildings or building additions of less than 2,000 square feet footprint on lots or available building sites of less than 2,000 square feet. D. Exception for public art. Except in residential zones, public art that has been individually accepted by the City Council for inclusion within the public art collection pursuant to Article 20 shall not be subject to the height limitations within the underlying zone. E. Exceptions for rooftop appurtenances. Unless otherwise noted, rooftop appurtenances for the housing of elevators, stairways, access vestibules, tanks, fans, or other building operating equipment not intended for human occupancy, pedestal paver systems and decks up to 18 inches in height above the surface of the roof, deck railings or guards, skylights, steeples, flag poles, chimneys, smokestacks, water tanks, or silos may be erected above the height limitations herein prescribed. Unenclosed shade structures covering up to 200 square feet in floor area, and other appurtenances associated with rooftop occupancy may be erected to a height not exceed ten feet above the surface of the roof. F. Exception for telecommunication towers. Where permitted, ground-mounted telecommunication towers may be erected above the height limitations within the underlying zone. G. Exception for accessory structures integral to principal uses in the I-L, I-Lb, I-M, I-Mb, and I-H zones. Where an accessory structure is integral to the operation of a principal use in the I-L, I-Lb, I-M, I-Mb, or I-H zone, such structure shall not be subject to the height maximums for the zone. Such accessory structures may include smokestacks, chimneys, cooling towers, water towers, and similar features. 7.6.2 Building length A. Additions to existing buildings 1. In the B-2b, additions to buildings existing as of the effective date of this Code that do not cumulatively exceed 50% of the building footprint as of the effective date of this Code are not required to meet minimum building length standards. However, any such additions shall increase conformity with the standards to the extent practicable. 2. In the B-3, B-5, B-6, TOD-1, and TOD-2 zones, additions to buildings existing as of the effective date of this Code that do not cumulatively exceed 25% of the building footprint as of the effective date of this Code are not required to meet minimum building length standards. However, any such additions shall increase conformity with the standards to the extent practicable. B. In the B-6 zone. Buildings located in the area east of Freedom Way shall be exempt from the minimum building length requirement. C. Lots with multiple street frontages. Where a minimum building length as a percentage of street frontage applies to a lot with multiple street frontages, the street with the highest traffic volume shall meet the established standard. In the case of a lot with two street frontages, the second frontage shall meet a reduced standard of 40%. If there are more than two frontages, there is no minimum requirement for any frontage beyond the two with the highest traffic volumes. D. The Planning Board may approve a different building length to comply with the standards of the City of Portland Design Manual provided that the building length standard is met to the maximum extent practicable. 7.6.3 Landscaped open space ratio In the calculation of landscaped open space ratio in the RN-4 and B-2 zones, green roofs may be counted as landscaped open space. 7.6.4 Lot area A. Small island lots 1. Existing developed and undeveloped lots in the IR-2 zone on Peaks Island that do not meet the 20,000 square foot minimum lot area standard as of the effective date of this Code shall be deemed to be small island lots, subject to modified lot area, street frontage, setback, lot coverage, and landscaped open space ratio requirements for residential uses. These standards apply only to lots in the IR-2 zone on Peaks Island. 2. The standards for small island lots shall apply to existing residential uses as well as new residential development on qualifying lots. The small island lot standards shall not apply to lots in nonresidential use or to nonresidential development in the IR-2 zone. 3. A new dwelling may be built on a small island lot subject to modified dimensional standards, provided that the lot is currently vacant, in residential use, used exclusively for parking, or contains structure(s) not used for residential purposes. 4. New small island lots may only be created by a single lot division of an existing lot, with the remaining developed portion meeting the standard dimensional requirements of the IR-2 zone. Further division of the remaining lot to create additional small island lots is prohibited. 5. Lots created as part of a cottage court development in the IR-2 zone shall not be considered small island lots, and shall be subject to the standards for cottage court development. B. Residential lots not served by public sewers. A lot in an unsewered residential district shall meet the provisions of the state Minimum Lot Size Law, 12 M.R.S. § 4807 et seq., or the applicable minimum lot area, whichever is larger. 7.6.5 Setbacks A. Permitted encroachments into required setback areas 1. Setbacks do not apply to fences, retaining walls, raised garden beds, and other similar structures. 2. Any setback may be occupied by a one-story entrance porch not enclosed, with or without a roof, if the area of the porch does not exceed 50 square feet within the side or rear setback or 250 square feet within the front setback. Stairs necessary to access a porch shall not be included in this calculation. The porch, including stairs, may project up to six feet into the setback. A basement bulkhead of similar size, but not more than 24 inches in height, is also permitted. A cornice eave, sill, canopy, chimney, bay window, balcony, or other similar architectural feature may encroach into any required setback a distance of not more than two feet. 3. Ground-mounted and building-mounted mechanical equipment may encroach into a required side or rear setback. This includes mechanical equipment related to the operation of the structure, such as heating, ventilation, and air conditioning (HVAC) equipment, personal electrical generators, and swimming pool pumps and filters. This allowance does not include window-mounted or through-the-wall air conditioning units. B. Build-to zone exceptions 1. Limited access roads are not considered street frontages for the purposes of build-to zone requirements, and are exempt from build-to zone standards. 2. Build-to zone requirements shall not apply to accessory structures, utility substations, alternative energy installations, and secondary building components such as truck loading docks, mechanical equipment enclosures, and refrigeration units. 3. The Planning Board or Planning Authority may approve a different front setback or build-to zone for irregularly shaped lots provided the front setback or build-to zone is met to the maximum extent practicable. 4. In the mixed-use and transit-oriented development zones, where buildings are set back more than 10 feet from a lot line abutting a street, or in the B-4 zone where buildings are set back more than 20 feet from a lot line abutting a street, a continuous, attractive, and pedestrian-scaled edge treatment shall be constructed along the street, consisting of street trees spaced at no more than 15 feet on center, approved by the City Arborist, and a combination of landscaping no less than four feet deep, ornamental brick or stone walls, or ornamental fencing. 5. In the B-3 zone, the Planning Board may require or approve an alternative build-to zone to comply with the design standards of Article 13 and the City of Portland Design Manual. 6. Where build-to zone requirements apply to a lot with multiple street frontages, the two streets with the highest traffic volume shall meet the established standard. In the case of a lot with two street frontages and a corner, buildings shall be sited at the street corner and both frontages shall meet the required build-to zone. In the case of a lot with three or more street frontages encompassing two or more corners, buildings shall be sited at the corners, and the two streets with the highest traffic volume shall meet the established standard. Build-to zone requirements shall not apply to any frontage beyond the two with the highest traffic volumes. 7. In the B-6 zone, build-to zone requirements do not apply to parking garages and public transportation facilities. Notwithstanding required setbacks, new structures located in the blocks located south of Fore Street and north of Commercial Street and its extension shall build to the key building envelopes shown on the City of Portland Height Map. Buildings located in the area east of Freedom Way shall not have a maximum front setback and shall not be required to build to the key building envelope perimeter. Parking structures and the buildings for public transportation facilities may, however, be set back beyond the key building envelopes (toward the interior of blocks), but may not occupy the land between the key building envelope and the street right-of-way. 8. Build-to zone requirements shall not apply to additions to existing buildings as follows: a. Build-to zone requirements shall not apply to vertical additions to existing buildings to meet minimum height requirements. b. In the B-1, B-2, and B-2b zones, build-to zone requirements shall not apply to additions to buildings existing as of the effective date of this Code that do not cumulatively exceed 50% of the building footprint as the effective date of this Code. However, any such additions shall increase conformity with the standards to the extent practicable. c. In the B-4, B-5, B-6, TOD-1, and TOD-2 zones, build to zone requirements shall not apply to additions to buildings existing as of the effective date of this Code that do not cumulatively exceed 25% of the building footprint as of the effective date of this Code. However, any such additions shall increase conformity with the standards to the extent practicable. C. Minimum setback exceptions for nonconforming lots 1. In the case of a nonconforming lot existing as of June 5, 1957 in the RN-1, RN-2, RN-3, and RN-4 zones and less than 100 feet deep, the front setback need not be deeper than 20% of the depth of the lot. 2. In the case of a nonconforming lot existing as of June 5, 1957 in a residential zone, the required side setback for principal structures may be reduced in order to provide a buildable width of up to 24 feet as follows: a. RN-1, RN-2: No side setback shall be reduced to less than 5 feet. b. RN-3: One side setback may be reduced to zero feet, provided the other shall be reduced to not less than 5 feet. A permanent maintenance easement a minimum of 5 feet in width shall be provided on the parcel adjacent to the lot line with the zero foot setback. 7.6.6 Stepbacks and areas of limited height adjacent to RN or open space zones A. A cornice eave, sill, canopy, chimney, bay window, balcony, or other similar architectural feature may project into any required stepback or area of limited height adjacent to an RN or open space zone a distance of not more than two feet. B. Building mounted mechanical equipment may encroach into a required stepback or area of limited height adjacent to an RN or open space zone by no more than 50% of the width of such required stepback. This includes mechanical equipment related to the operation of the structure, such as heating, ventilation, and air conditioning (HVAC) equipment. 7.6.7 Street frontage In the IR-1 and IR-2 zones, a lot that is buildable pursuant to Subsection 4.3.1 and lots created after July 15, 1985, which are not part of a subdivision need not provide street frontage if access is available by means of a permanent easement or right-of-way which existed as of July 15, 1985. Such easement or right-of-way shall have a minimum width of 16 feet and a minimum travel width of eight feet except that an easement or right-of-way providing access for three or more lots or providing the only means of access to a parcel or parcels of three acres or more, shall meet the construction requirements of Chapter 25, Article III of the City of Portland Code of Ordinances. In the IR-1 zone, such easement or right-of-way shall conform to the requirements contained within the City of Portland Technical Manual. In the IR-2 zone, such easement or right-of-way shall be a minimum of 32 feet wide. Such easement or right-of-way shall be sufficient to permit municipal service delivery. 7.6.8 Additions to and/or relocations of designated historic structures Additions to and/or relocations of designated historic structures or structures determined by the Historic Preservation Board to be eligible for such determination shall not be required to meet minimum building height, or minimum building length standards. MAP: Portland, ME [image omitted; see the official code] MAP: Portland, ME [image omitted; see the official code]

Ask a question about Portland law

Corpus searches the Portland sections it holds and shows the ones that match, with their citations. Free, no sign-in.