8.1 COASTAL FLOOD RESILIENCE OVERLAY (CFROZ)

8.1.1 Purpose The purpose of the Coastal Flood Resilience Overlay Zone (CFROZ) is to protect persons and structures from the adverse effects of sea level rise and storm surge associated with climate change by: A. Advancing adaptation strategies for long-term resilience. B. Complementing public realm resilience measures by guiding development on private property. C. Mitigating flood risks in a way that is specific to Portland’s unique hydrological conditions and affected uses, particularly in areas that are not currently recognized as flood zones but are vulnerable to future sea level rise. D. Providing a balanced framework in which flood protection requirements are proportional to the vulnerability and risks of various occupancies. 8.1.2 Applicability The provisions of the CFROZ shall apply to property or proposed projects wholly or partially within the boundaries of the Coastal Flood Resilience Overlay Zone as depicted on the City of Portland Zoning Map. However, property or proposed projects within the CFROZ boundary that are also located wholly or partially within special flood hazard areas with a BFE of 13 feet or higher as defined in Article 12 shall be exempt from the provisions of the CFROZ. 8.1.3 Relationship to underlying zoning The CFROZ constitutes an overlay zone. The provisions of the underlying zoning, as they may be amended from time to time, continue to apply, except as expressly superseded by this Section. Where conflicts exist between this Section and the remainder of this Code, the more restrictive provision shall govern. 8.1.4 Use classifications A. For the purposes of this Section, uses in the CFROZ shall be classified as follows: 1. Critical uses. Critical uses generally include residential, governmental, educational, medical, emergency, and related high-risk uses. 2. Non-critical uses. Non-critical uses generally include retail, restaurant, commercial, and related medium-risk uses. 3. Exempt uses. Exempt uses generally include low risk and low occupancy uses such as parking, construction yards, and storage. B. Table 8-A shall determine whether a use is classified as critical, non-critical, or exempt. For uses not listed in Table 8-A, the Building Authority or the Planning Authority shall determine the classification based upon the most nearly comparable land use. Water-dependent uses shall be considered exempt. C. All accessory uses shall be considered non-critical, with the following exceptions: 1. Accessory dwelling units. 2. Child care centers and small child care facilities greater than 1,000 square feet in floor area. 3. Clinics greater than 1,000 square feet in floor area. TABLE 8-A: CLASSIFICATION OF USES AS CRITICAL, NON-CRITICAL, OR EXEMPT | | Critical | Non-Critical | Exempt Residential | Single-family dwellings | ⏺ | | Residential | Two-family dwellings | ⏺ | | Residential | Three-family dwellings | ⏺ | | Residential | Four-family dwellings | ⏺ | | Residential | Townhouse dwellings | ⏺ | | Residential | Multi-family dwellings | ⏺ | | Residential | Live/work dwellings | ⏺ | | Residential | Group homes | ⏺ | | Residential | Lodging houses | ⏺ | | Institutional | Child care centers + small child care facilities | ⏺ | | Institutional | Clinics | ⏺ | | Institutional | Cultural facilities | ⏺ | | Institutional | Elementary, middle, and secondary schools | ⏺ | | Institutional | Emergency shelters | ⏺ | | Institutional | Governmental uses | ⏺ | | Institutional | Hospitals | ⏺ | | Institutional | Places of assembly | ⏺ | | Institutional | Post-secondary schools | ⏺ | | Institutional | Residential care facilities (small) | ⏺ | | Institutional | Residential care facilities (large) | ⏺ | | Commercial | Adult business establishments | | ⏺ | Commercial | Animal-related services | | ⏺ | Commercial | Auto, boat, and related dealerships | | ⏺ | Commercial | Auto service stations | | | ⏺ Commercial | Bars | | ⏺ | Commercial | Bed and breakfasts | ⏺ | | Commercial | Exhibition, meeting, and convention halls | | ⏺ | Commercial | Funeral homes | | ⏺ | Commercial | General offices | | ⏺ | Commercial | General services | | ⏺ | Commercial | Greenhouse/Nursery, retail | | | ⏺ Commercial | Hostels | ⏺ | | Commercial | Hotels | ⏺ | | Commercial | Marijuana retail store | | ⏺ | Commercial | Market garden | | | ⏺ TABLE 8-A: CLASSIFICATION OF USES AS CRITICAL, NON-CRITICAL, OR EXEMPT | | Critical | Non-Critical | Exempt Commercial | Neighborhood nonresidential reuse | | ⏺ | Commercial | Office park | | ⏺ | Commercial | Recreation and amusement centers | | ⏺ | Commercial | Registered marijuana dispensary | | ⏺ | Commercial | Restaurants | | ⏺ | Commercial | Retail | | ⏺ | Commercial | Small-scale marijuana caregiver | | ⏺ | Commercial | Specialty food service | | ⏺ | Commercial | Theaters and performance halls | | ⏺ | Commercial | Veterinary services | | ⏺ | Industrial | Communication studios | | ⏺ | Industrial | Construction & engineering services | | ⏺ | Industrial | Dairies | | | ⏺ Industrial | Fish waste processing | | ⏺ | Industrial | Food & seafood processing, packing, and distribution | | ⏺ | Industrial | High-impact industrial uses | | ⏺ | Industrial | Impound lots | | | ⏺ Industrial | Intermodal transportation facilities | | ⏺ | Industrial | Laboratory and research facilities | | ⏺ | Industrial | Low-impact industrial | | ⏺ | Industrial | Lumber yards | | | ⏺ Industrial | Marijuana cultivation facility (<2,000 SF plant canopy) | | | ⏺ Industrial | Marijuana cultivation facility (2,000-7,000 SF plant canopy) | | ⏺ | Industrial | Marijuana cultivation facility (>7,000 SF plant canopy) | | ⏺ | Industrial | Marijuana manufacturing facilities | | ⏺ | Industrial | Marijuana testing facilities | | ⏺ | Industrial | Printing and publishing | | ⏺ | Industrial | Recycling facilities | | | ⏺ Industrial | Self-storage | | ⏺ | Industrial | Solid waste disposal facilities | | | ⏺ Industrial | Studios for artists and craftspeople | | ⏺ | Industrial | Telecommunication towers (ground-mounted) | | | ⏺ Industrial | Warehousing and distribution | | ⏺ | TABLE 8-A: CLASSIFICATION OF USES AS CRITICAL, NON-CRITICAL, OR EXEMPT | | Critical | Non-Critical | Exempt Other | Agriculture | | | ⏺ Other | Boathouses and storehouses for fishing equipment | | | ⏺ Other | Campgrounds | | | ⏺ Other | Cemeteries | | | ⏺ Other | Marinas and yacht clubs | | | ⏺ Other | Marine uses | | | ⏺ Other | Off-street parking | | | ⏺ Other | Parks and open spaces | | | ⏺ Other | Social service centers | ⏺ | | Other | Solar energy system (minor) | | | ⏺ Other | Solar energy system (major) | | | ⏺ Other | Utility substations | ⏺ | | Other | Wharves, piers, docks, and landing ramps | | | ⏺ Other | Wind energy system (minor) | | | ⏺ Other | Wind energy system (major) | | | ⏺ 8.1.5 Projects subject to the standards of the CFROZ A. Any development located within the established boundary of the CFROZ, and which meets the thresholds listed below, shall be subject to the standards of the CFROZ. 1. All new construction containing a critical use or uses. 2. New construction of greater than 1,000 square feet containing non-critical uses only. 3. Any addition of greater than 1,000 square feet containing critical or non-critical uses. B. Where a change of use occurs within the CFROZ, all portions of a building containing a critical use and the critical systems supporting such use shall meet the CFROZ standards. Changes of use to non-critical uses shall not require compliance with the CFROZ standards. C. Structures within the CFROZ that are 50,000 square feet or greater in gross floor area and undergoing substantial improvement are required to meet the CFROZ standards when they contain a critical use or uses. For the purposes of this subsection, substantial improvement shall be as defined in Article 12. 8.1.6 Use and dimensional requirements A. Sea level rise design flood elevation (SLR-DFE). The required SLR-DFE shall be determined by use classification. For mixed-use developments that contain uses in different classifications sharing a ground floor, each use shall be addressed independently. FIGURE 8-A: CFROZ USE CLASSIFICATIONS AND DESIGN FLOOD ELEVATION [image omitted; see the official code] 1. Critical uses. The SLR-DFE for all critical uses (SLR-DFE-C), including the critical systems serving such uses, shall be a minimum of one foot above SLR-BFE, as defined in Article 3. In a proposed project containing critical uses, the following building and site elements are permitted to be located below the SLR-DFE: a. Lobbies, entries, egress stairs, and elements required for vertical circulation from the SLR-DFE to grade, such as elevators, ramps, and stairs. b. Parking. c. Storage. d. Flood protection equipment. 2. Non-critical uses. The SLR-DFE for non-critical uses (SLR-DFE-NC), including the critical systems serving those uses, shall be no lower than two feet below SLR-BFE, as defined in Article 3. The minimum elevation of the underside of the beams supporting the second floor in a multi-story building, or the roof in a one-story building, shall be no less than 13 feet above SLR-BFE. In a proposed project containing non-critical uses, the following building and site elements are permitted to be located below SLR-DFE: a. Lobbies, entries, egress stairs, and elements required for vertical circulation from the SLR-DFE to grade, such as elevators, ramps, and stairs. b. Parking. c. Storage. d. Flood protection equipment. 3. Exempt uses. Exempt uses shall not be subject to dimensional requirements with respect to SLR-BFE. B. Building height. Within the CFROZ, if a proposed project contains principal critical or non-critical uses on the ground floor, height shall be measured from the SLR-DFE or from average grade, whichever is higher. C. Exemptions for required ramping and stairs. Ramping and stairs necessary to meet any required SLR-DFE may be included within the calculation of area required to meet landscaped open space ratio requirements, and shall not be included within the calculation of lot coverage. Ramping and stairs necessary to meet any required SLR-DFE may be located in any required front yard, interior or corner side yard, or rear yard, and in cases where build-to requirements apply, shall be considered to meet the build-to percentage. D. Hazardous materials. Any hazardous materials shall be fully contained and elevated a minimum of two feet above SLR-DFE.

Ask a question about Portland law

Corpus searches the Portland sections it holds and shows the ones that match, with their citations. Free, no sign-in.