§ 5-1060 — - Approval of permit application
Code of Ordinances of the City of Dearborn, Michigan (2026 S-07: Code and Zoning updated through September 22, 2026) · Dearborn City Code § 5-1060
Corpus is an independent public-information project, not the official City of Dearborn website. Stable reference: corpuslaw.us/code/d9dab0c1-9d01-4e81-a520-e6b49b753f20
Sec. 5-1060. - Approval of permit application.
(a) The department shall issue a permit for installing any gas designed furnace or boiler which has been approved by the American Gas Association. It shall be unlawful to install or cause to be installed in the city any such furnace or boiler which has not first been approved by the American Gas Association. (b) A list of all conversion type gas burners shall be maintained by this department, which, through the arrangement of parts, suitability of materials, strength of parts, electric or other control, thermostatic arrangement, sensitivity of automatic features, positiveness of ignition, and possibility of explosion, have been found, by best or acceptable proof from the American Gas Association or some equally competent laboratory, to be acceptable to the heating board of appeals and this department for use in the city under the provisions of this division. (c) Before a permit will be issued for a conversion type gas fired burner, each applicant for the installation of such burners must furnish the department with a photostatic copy or other suitable evidence of the approval or the official certification by the American Gas Association; provided, however, that if a particular trade name of burner is listed for the current year in the Directory of Approved Gas Appliances and listed Accessories, or a supplement thereto, as published by the American Gas Association Testing Laboratories, evidence of further approval or certification will not need to be furnished by the applicant. (d) In addition to the approval or certification by the American Gas Association, as hereinabove required for conversion type burners, such conversion type burner must meet the two following requirements: (1) If the burner is of the single port spreader flame type, the main body of the burner including mixer head and mixer tube shall be of wrought iron or wrought steel construction. The burner head shall be of wrought iron, alloy cast iron, or other heat resisting alloys. The spreader plate shall have a thickness of one-fourth inch if it is constructed of wrought iron, alloy wrought iron, other heat resisting alloys, or ceramic material, but if the spreader is made of metal containing at least 25 percent of nickel or chrome alloy, or some other equally heat resisting metal, the spreader need not be more than one-eighth inch thick. (2) If the burner is a drilled multiple port type, the cast iron burner heads with raised drill ports shall be installed without baffles. (Ord. No. 81-65, § 11.4, 11-4-81)
Ask a question about Dearborn law
Corpus searches the Dearborn sections it holds and shows the ones that match, with their citations. Free, no sign-in.
