Sec. 5-395. - Same - Exceptions.

Fulltime licensed personnel in attendance will not be required for the following equipment: (1) Boilers or pressure vessels operating under banked operation or under the requirements of section 5-313. (2) Low pressure steam boilers with 1,000 square feet aggregate or less of heating surface. (3) Low pressure hot water heating and hot water supply boilers having 1,000 square feet aggregate or less of heating surface. (4) Direct low fired pressure hot water heaters used for purposes other than space heating whose self-contained capacity does not exceed 120 gallons; whose heating surface does not exceed an aggregate total of 750 square feet regardless of pressure or temperature conditions. Such apparatuses shall, however, be designed and constructed for the pressure carried, shall be equipped with A.S.M.E. approved safety valve and appliances, and must comply with all requirements of the state board of boiler rules and the city boiler code. (5) All rooftop refrigeration systems under 150 tons aggregate provided they are properly monitored and maintained by an approved ASHRAE and Mechanical Refrigeration Code or Underwriters Laboratory energy management system. The compliance officer and the director of the economic and community development department may modify these limitations, if the plant designs are such that the operation does not endanger the life, safety or health of individuals. Operators of refrigeration systems under these exceptions shall be required to file an annual reliability report to the board of safety engineers. (6) All refrigeration systems classified as a low probability system as described in the 2006 Michigan Mechanical Code during established non-core business hours and/or operations, provided the system is equipped with a central control board as defined in subsections 5-396(b) through (j). (Ord. No. 85-323, § 4.2(l), 6-4-85; Ord. No. 95-631, 4-18-95; Ord. No. 98-742, 10-20-98; Ord. No. 99-787, 8-3-99; Ord. No. 09-1262, 12-14-09)

Ask a question about Dearborn law

Corpus searches the Dearborn sections it holds and shows the ones that match, with their citations. Free, no sign-in.