§ 5-396 — - Same - Centralized control

Code of Ordinances of the City of Dearborn, Michigan (2026 S-07: Code and Zoning updated through September 22, 2026) · Dearborn City Code § 5-396

Corpus is an independent public-information project, not the official City of Dearborn website. Stable reference: corpuslaw.us/code/151d982d-4d65-4e97-96e0-228d8557b67f

Sec. 5-396. - Same - Centralized control.

(a) Post of duty requirements for all refrigeration systems and plants with low pressure boilers with an aggregate of not more than 5,000 square feet of heating surface are as follows: the attending licensed operator may be absent from the area monitored by a central control station in which the equipment is located for not more than four hours, provided that the safety of the plant is not jeopardized by his absence. (b) A central control board must monitor all levels of operation of equipment being controlled, including all safety alarms, valve states, temperatures and pressures as necessary to ensure complete safe operation. All equipment shall have manual reset controls on equipment with alarms. (c) A central control station must be continuously manned by personnel licensed to operate all classes of equipment under centralized control. Personnel may be absent for up to ten minutes provided that an alert pager system is in use and approved by the department of economic and community development. (d) A central control board failure or "no signal" condition shall cause immediate shutdown of the equipment involved. All such equipment, when shut down, shall require manual restart at the equipment location. All shut down alarms causing damage to equipment shall be reported to the department in writing within 72 hours of detailing the type of alarm and damage caused. (e) The central control station operator shall maintain one year a continuous separate readout of all system messages. In addition, a working log may be kept. The operator must obtain a system readout of all equipment at least twice per shift. (f) The central control system, together with all operator requirements, and any significant changes that alter the intent of any previously granted appeal, shall be approved by formal appeal to the board of safety engineers or the department for the interim period. The written approval shall remain in force only so long as the system is maintained and operated in a manner such as to eliminate any undue safety hazard to life, limb, or property. (g) The central control system must have the approval of Underwriters' Laboratories or other nationally approved independent testing laboratories, national fire codes, National Electric Code, 1990 BOCA Mechanical Code, and all amendments thereto. (h) The fee for a special permit required to be issued annually is to be based on the size of the equipment and chapter 9 of this Code. (i) Licensed personnel may continue to operate equipment under their control as of June 4, 1985, if approved by the department. Any new employee must obtain the proper license for the equipment to be operated as required by this article. The department may require a higher grade license if unusual or hazardous conditions warrant same. The license requirements shall be subject to review if there is any change or alteration in equipment at an existing location. (j) Any holder of a first class engineer license issued under the requirements of Ordinance No. 81-66, as amended, which license was in good standing on June 4, 1985, shall, upon payment of fees therefore, be entitled to a first class stationary engineer license and a first class refrigeration operator license without further requirements. (Ord. No. 85-323, §§ 4.2(m)—(o), 6-4-85; Ord. No. 95-631, 4-18-95; Ord. No. 98-742, 10-20-98; Ord. No. 99-787, 8-3-99; Ord. No. 09-1262, 12-14-09)

Ask a question about Dearborn law

Corpus searches the Dearborn sections it holds and shows the ones that match, with their citations. Free, no sign-in.