Sec. 8-4-23. - Addition of Section 1012 of 2015 Michigan Mechanical Code, Post of Duty for Boiler Facilities and Steam Prime Mover Facilities.
In accordance with Section 8b(11) of the Stille-DeRossett-Hale Single State Construction Code Act, being MCL 125.1508b(11), the City adds Section 1012, Post of Duty for Boiler Facilities and Steam Prime Mover Facilities, to the 2015 Michigan Mechanical Code, which provisions were contained in the 1984 Detroit City Code prior to July 31, 2001, and concern administration and enforcement: [Note: Sections 1011 through 1011.2 of the International Mechanical Code, 2015 Edition, were not adopted by the Director of the Michigan Department of Licensing and Regulatory Affairs.] SECTION 1012 POST OF DUTY FOR BOILER FACILITIES AND STEAM PRIME MOVER FACILITIES 1012.1 Definitions. For purposes of Section 1012 of this code, the following terms shall have the meanings ascribed to them by this section: Attending licensed operator means the person who: (1) Is licensed under this code, commensurate with the designated classification of the boiler facility, as a low-pressure boiler operator under Section 118 of this code, a high-pressure boiler operator under Section 119 of this code, a third-class stationary engineer under Section 120 of this code, a second-class stationary engineer under Section 121 of this code, or a first-class stationary engineer under Section 122 of this code; (2) Is designated by the person having control or management of the equipment, property, or premises to operate equipment covered by this code; and (3) Is physically available to fulfill the post of duty requirements of Section 1012 of this code. Licensed operator in responsible charge means the person who: (1) Is licensed under this code, commensurate with the designated classification of the boiler facility, as a low-pressure boiler operator under Section 118 of this code, a high-pressure boiler operator under Section 119 of this code, a third-class stationary engineer under Section 120 of this code, a second-class stationary engineer under Section 121 of this code, or a first-class stationary engineer under Section 122 of this code; and (2) Is selected and designated by the person having control or management of the equipment, property, or premises to assume full charge while on duty for the complete and safe operation of equipment covered by this code. Post of duty means the station or place to be occupied by a person who is licensed under this code, commensurate with the designated classification of the boiler facility, as a low-pressure boiler operator under Section 118 of this code, a high-pressure boiler operator under Section 119 of this code, a third-class stationary engineer under Section 120 of this code, a second-class stationary engineer under Section 121 of this code, or a first-class stationary engineer under Section 122 of this code while carrying out his or her assigned duties and responsibilities. Steam prime mover means a turbine or an engine, which receives energy from steam and converts the energy into mechanical power that is used to drive machinery. 1012.2 General. Except as otherwise permitted in Section 1012 of this code, the presence of an attending licensed operator, or a licensed operator in responsible charge acting as an attending licensed operator, who continuously maintains the post of duty as specified in Section 1012 of this code shall be required when a boiler and its steam prime mover are in operation. A boiler and its steam prime mover shall be considered in operation unless the fuel supply has been permanently disconnected so that no additional fuel will be introduced, either automatically or manually, into the firing chamber, the air supplied to the firing chamber is below that used under normal conditions, and the pressure in the boiler continues to approach atmospheric pressure. 1012.3 Operation of low-pressure steam boilers and low-pressure hot water boilers outside normal business hours. The presence of an attending licensed operator shall not be required when the premises served by a low-pressure steam boiler or boilers, or a low-pressure hot-water boiler or boilers, is not normally occupied or is not in use to conduct business or industry, such as during nights, weekends and holidays, when the premises is closed to operations or public usage, provided, that the following requirements are met: (1) The aggregate heating surface of the boiler facility shall not exceed 1,500 square feet; (2) Steam boilers shall be equipped with approved safety valves set and stamped to relieve at not more than 15 psi, and hot water boilers shall be equipped with approved safety relief valves set and stamped to relieve at not more than 160 psi; (3) An approved automatic means of feeding water into the boilers shall be provided; (4) Boilers shall be equipped with an approved pressure control with a maximum setting not to exceed 90 percent of the setting of the safety valves or safety relief valves and, in addition, hot water boilers shall be equipped with an approved temperature control with a maximum setting of 250 degrees Fahrenheit; (5) An approved control, requiring manual re-setting, shall be installed which will shut off the fuel and air supply in the event of low water; (6) During this period, the boilers shall be used only for space heating, indirect hot water supply heating, or the maintaining of temperatures of idle processes; and (7) Such method of operation shall not be put into effect until written request is submitted to, and written permission has been granted by, the Buildings, Safety Engineering, and Environmental Department. 1012.4 Licensed operator in responsible charge required. Except as provided for in Section 1012.3 of this code, it shall be unlawful to operate a boiler facility or a steam prime mover facility as specified in Section 1012 of this code without a licensed operator in responsible charge thereof who possesses the required license, or a higher classification of the required license, commensurate with the designated classification of the boiler facility or the steam prime mover facility. 1012.5 Post of duty for licensed operator in responsible charge. The post of duty of the licensed operator in responsible charge of a boiler facility or a steam prime mover facility shall be within the actual facility. When he or she must also serve as attending licensed operator, his or her post of duty shall be maintained as specified in Section 1012 of this code. When other operators, serving as attending licensed operators, are on duty under the licensed operator in responsible charge, the latter may absent himself or herself from his or her post of duty for the purpose of performing his or her regularly assigned duties for reasonable periods, provided, that the time absent is not more than two hours at a time and not more than a total of four hours in any eight-hour period and that, in the opinion of the Buildings, Safety Engineering, and Environmental Department, his or her absence does not jeopardize the safe operation of the facility. 1012.6 Attending licensed operator for boiler facilities. A person serving as attending licensed operator of a boiler facility under the direction of the licensed operator in responsible charge may operate a boiler facility covered by the license of the latter, provided, that the attending licensed operator possesses at least a Low-Pressure or a High-Pressure Boiler Operator License, which is commensurate with the designated classification of the boiler facility. 1012.7 Attending licensed operator for steam prime mover facilities. An attending licensed operator of a steam prime mover facility who serves under the direction of the licensed operator in responsible charge may monitor the steam prime mover covered by the license of the licensed operator in responsible charge, provided, that the attending licensed operator possesses at least a Third-Class Stationary Engineer License. 1012.8 Post of duty for high-pressure steam boiler and high-pressure hot water boiler facilities. The post of duty of the attending licensed operator of high-pressure steam boiler and high-pressure hot-water boiler facilities shall be in the room where the boiler or boilers are located and in immediate adjoining rooms, if so arranged, which contain the auxiliaries pertinent to the operation of said boilers, provided, that, in the opinion of the Buildings, Safety Engineering, and Environmental Department, the wall openings between the auxiliary and boiler rooms are readily accessible for passage, visibility, and audibility. 1012.9 Post of duty for low-pressure steam boiler facilities. The post of duty of the attending licensed operators of low-pressure steam boiler facilities shall be as follows: (1) In facilities having an aggregate of more than 1,000 square feet of heating surface, the post of duty of the attending licensed operator shall be in the room where the boiler or boilers are located and in immediate adjoining rooms, if so arranged, which contain the auxiliaries pertinent to the operation of said boiler or boilers, provided, that, in the opinion of the Buildings, Safety Engineering, and Environmental Department, the wall openings between the auxiliary and boiler rooms are readily accessible for passage, visibility, and audibility; (2) In facilities having an aggregate of more than 750 but not more than 1,000 square feet of heating surface, the post of duty of the attending licensed operator shall be as described in Subsection (1) of this section, provided, that he or she may be absent from the room where the boiler or boilers are located for not more than 60 consecutive minutes when, in the opinion of the Buildings, Safety Engineering, and Environmental Department, the safety of the facility is not jeopardized by his or her absence; (3) In facilities having an aggregate of more than 300 square feet but not more than 750 square feet of heating surface, the post of duty of the attending licensed operator shall be on the premises, provided, that, in the opinion of the Buildings, Safety Engineering, and Environmental Department, the absence of the attending licensed operator from the boiler room does not jeopardize the safe operation of the facility; and (4) In facilities having an aggregate of 300 or less square feet of heating surface, no attending licensed operator is required. 1012.10 Post of duty for low-pressure hot water boiler facilities. The post of duty of the attending licensed operator of low-pressure hot water boiler facilities with an aggregate of more than 1,000 square feet of heating surface shall be on the premises. 1012.11 Unapproved change in floor plan or unsuitable duty assignment. Where the floor plan of the building or structure that houses boilers, steam prime movers and their accessories, auxiliaries and regulating equipment is changed without the approval of the Buildings, Safety Engineering, and Environmental Department, or the assigned duties of the required licensed operating personnel are inconsistent with Section 1012 of this code, a violation may be issued and correction of the offending conditions shall be made in a manner acceptable to the Buildings, Safety Engineering, and Environmental Department. 1012.12 Prohibited actions. (a) An attending licensed operator or a licensed operator in responsible charge shall not leave his or her post of duty, except as otherwise permitted in Section 1012 of this code, or relinquish his or her responsibilities for the operation of boilers or steam prime movers to a person who is not licensed in accordance with the requirements of this code. (b) A person having control or management of a boiler facility or a steam prime mover facility shall not operate or cause to be operated such apparatus contrary to the requirements of this code, or allow or require the necessary licensed personnel to leave their post of duty except as permitted in Section 1012 of this code.
(Code 1964, §§ 2.1, 2.11, 2.15, 2.19, 3.1, 3.9, 3.10, 3.11, 3.12, 4.0, 4.1, 4.2, 4.3, 4.5, 4.7, 4.8; Ord. No. 706-G, § 1(2.1, 2.11, 2.15, 2.19, 3.1, 3.9, 3.10, 3.11, 3.12, 4.0, 4.1, 4.2, 4.3, 4.5, 4.7, 4.8), eff. 7-4-1972)
Ask a question about Detroit law
Corpus searches the Detroit sections it holds and shows the ones that match, with their citations. Free, no sign-in.