§ 8-9-192 — Emergency signaling devices

2019 Detroit City Code (Supp. No. 4: codified through Ordinance No. 2024-17, effective March 26, 2024, and Ordinance No. 2024-32, effective June 25, 2024) · Detroit City Code § 8-9-192

Corpus is an independent public-information project, not the official City of Detroit website. Stable reference: corpuslaw.us/code/2c3c6a45-abf9-4136-9f07-ede122237024

Sec. 8-9-192. - Emergency signaling devices.

(a) In all buildings, elevators shall be provided with the following emergency signaling devices: (1) Audible signaling devices operable from the emergency stop switch or button, where required by Section 8-9-158(6) of this Code and from a switch or bottom marked alarm that is located in or adjacent to each car operating panel: a. The alarm switch or button shall illuminate when activated. The signaling device shall be located inside the building and audible inside the car and outside the hoistway. One audible signaling device shall be provided for each elevator; b. Have a rated sound pressure rating of not less than 80 dBA and no more than 90 dBA at ten feet (3.05 m); c. Respond without delay after the switch or button has been activated; d. Be located inside the building and audible inside the car and outside the hoistway; e. For elevators with a travel greater than 100 feet (30.48 m), be duplicated as follows: 1. One device shall be mounted on the car; and 2. A second device shall be placed at the designated level; and f. One signaling device may be used for a group of elevators. (2) Means of two-way communication between the car and a readily accessible point outside the hoistway which is available to emergency personnel (telephone, intercom, and the like). The means to activate the two-way conversation does not have to be provided in the car. (b) Where the audible signaling device(s), or the means of the two-way conversation, or both, are normally connected to the building power supply, they shall automatically transfer to a source of standby or emergency power after the normal power supply fails. The power source shall be capable of providing for the operation of the audible signaling device and illumination of the alarm switch for at least one hour, and the means of two-way conversation for at least four hours. (c) In buildings where an attendant, such as a building employee or security guard, is not continuously available to take action when the required emergency signal is operated, the elevators shall be provided with a means within the car for communication with or signaling to a service that is capable of taking appropriate action when a building attendant is not available. A standby or emergency power system that conforms to the requirements of Subsection (b) of this section shall be provided.

Ask a question about Detroit law

Corpus searches the Detroit sections it holds and shows the ones that match, with their citations. Free, no sign-in.