For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 50-37 — Application materials for site plan approval

Code of Ordinances of the City of East Lansing, Michigan (Codified through Ordinance No. 1552, enacted August 12, 2025. (Supp. No. 16, Update 4)) · East Lansing Municipal Code § 50-37

Corpus is an independent public-information project, not the official City of East Lansing website. Stable reference: corpuslaw.us/code/78a0c7da-1827-4624-bd5a-731e282e81ce

Sec. 50-37. - Application materials for site plan approval.

The planning and zoning official shall determine the format(s) and number of copies of the application materials necessary to facilitate review by other departments and agencies, presentation at public meetings, inclusion in printed reports and incorporation into public records. The application shall include sufficient information and detail to determine if the proposed development meets applicable standards of review under this chapter. The information shall be prepared and signed by a planner, architect, engineer, landscape architect, surveyor or other appropriate professional so that the city may rely on its accuracy and feasibility. The application shall typically include the following drawings and information, as may be relevant to the nature of the application and the city's review requirements: (1) A site plan, as defined in section 50-9 of this chapter, showing the proposed size and location of buildings, parking and access facilities, free-standing signs and other improvements to be constructed or installed on the site, and the proposed use and treatment of other areas on the site. The site plan shall be clearly dimensioned to show the setbacks of buildings and parking areas, the separation between buildings and parking areas, the height of buildings, the width of roadways and driveways, the size of parking spaces, and other elements of the site plan as necessary to ensure the site plan complies with the applicable dimensional standards of this chapter. (2) An existing topographic survey and boundary description of the site, drawn at the same scale as the site plan, showing the following existing conditions: a. Exact dimensions and size of the site and any easements, rights-of-way or other physical encumbrances on the site; b. Location, size, and composition of all existing buildings, paved areas and other improvements; c. Existing ground contours at two-foot intervals or less, indicating the direction of surface drainage flow, and the type of surface soils present; d. Location and species of all existing individual trees which have a diameter (d.b.h.) of four inches or more, or where significant clusters of trees and shrubs are present, the location and general composition of such clusters, and an indication of which individual trees or tree clusters will be removed or retained; e. Location and boundaries of water bodies, including, but not limited to rivers, streams, lakes, ponds, marshes, city or county drains and manmade surface drainageways; f. Where wetland of any size may be present, as indicated on the city's wetland inventory map, a report prepared by a qualified wetland consultant which verifies the presence of any wetland, establishes the boundary of any wetland, describes the character and quality of any wetland, and indicates if any wetland may be regulated by the state or protected by chapter 49 of the City Code; except, this requirement may be waived by the city engineer where it is clearly evident that the proposed site changes would not disturb any wetland on the property; g. The boundary and elevation of areas of special flood hazard and floodways, as defined in chapter 18 of the City Code; h. Location and size of all existing utility lines, manholes, catch basins, and fire hydrants on or near the site which may be used to serve the site; i. Delineation of areas on the site which are known or suspected to be environmentally contaminated, together with a report on the status of cleanup or closure. (3) A proposed landscape plan which, at a minimum, conforms to the requirements of section 50-840 of this chapter, drawn at the same scale as the site plan or larger, showing: the location and size of areas to be landscaped; the type, size and placement of plant materials to be installed; the type, size and location of existing trees and significant clusters of trees or shrubs to be preserved; the location and height of proposed earth berms; and the size and design of fences or other screens to be erected. For clarity, detailed plans drawn at a larger scale than the site plan may be submitted to show the typical design and treatment of similar landscaped areas and fencing. (4) Proposed preliminary engineering plans, drawn at the same scale as the site plan or larger, showing the following proposed conditions: a. Ground contours at two-foot intervals or less, indicating the direction of surface drainage flow; b. Ground and floor elevations of buildings and other site improvements drawn to two decimal places; c. Location, dimensions and composition of roadways, driveways, curb cuts, parking and access facilities, curbing and sidewalks; d. Location and size of public utility connections, fixtures and easements; e. Stormwater management plan including the design of sewers, outlets, and retention or detention ponds, with sufficient data regarding site runoff estimates and off-site drainage patterns to permit review of the feasibility and permanence of drainage detention and/or retention as well as the impact on local surface and groundwater; f. Location and delineation of any wetland that would be disturbed and the location, existing character and proposed treatment of any proposed mitigation sites; g. Location and screening of exterior trash storage facilities; h. Type, height and placement of exterior light fixtures, including fixtures mounted on poles and on buildings; i. Location and status of any floor drains in existing or proposed structures on the site, indicating the point of discharge for all drains and pipes; j. Location of any on-site wastewater collection, treatment and disposal system; k. Location of existing and proposed public and private drinking water wells, monitoring wells, irrigation wells, test wells or wells used for industrial processes; l. Inventory of hazardous substances to be stored, used or generated on-site, in a format acceptable to the local fire marshal (including CAS numbers); m. Descriptions of type of operations proposed for the property with drawings showing size, location, and description of any proposed interior or exterior areas for storing, using, loading or unloading hazardous substances, hazardous wastes, and/or polluting materials; n. Description and location for any existing or proposed aboveground and belowground storage facilities; o. Completed environmental permits checklist on the form provided by the planning and zoning official. (5) A traffic impact study if so required under the provisions of division 4 of this article. (6) Proposed preliminary building plans, drawn at an accurate scale, including: a. Interior floor plans showing the arrangement and use of rooms for each floor, maximum occupancy and seating plans where applicable; b. Building elevations showing the size, height, architectural style, and exterior materials to be used, and areas intended to be used for wall-mounted signage. (7) A descriptive text which addresses the following items: a. The design principles followed in preparing the plans and how the plans address the objectives and criteria specified in section 50-38; b. The type of occupants anticipated and the market the project is intended to serve; for nonresidential uses, the intended hours of operation and the expected number of employees; for residential uses, the expected occupancy, the period of leases, and the approximate range of sale prices or rental rates of the proposed dwelling units; c. The land use statistics reflected in the proposed plans as measured against the required conditions in the applicable zoning district; d. A rationale for any variances from the requirements of this chapter which may be requested as part of the application. e. The proposed construction schedule and staging of the development. (8) Proposed plans showing compliance with the requirements of the public art requirement of section 50-38(6) of the City Code or a detailed narrative of the basis for an exemption from the requirement pursuant to section 50-38(6)d.

(Ord. No. 1061, 2-7-2006; Ord. No. 1163, 2-20-2007; Ord. No. 1162, 4-17-2007; Ord. No. 1313, 3-4-2014; Ord. No. 1319, 2-18-2014; Ord. No. 1339, 10-7-2014; Ord. No. 1543, 7-15-2025)

Ask a question about East Lansing law

Corpus searches the East Lansing sections it holds and shows the ones that match, with their citations. Free, no sign-in.