Sec. 12-12. - Fire department building plan review and design standards.
The fire department shall provide plan review comments for applicable plans as specifically provided for in the building code. The review comments shall be forwarded to the building division to be incorporated into a single review. The fire department shall be one (1) of the signatories necessary for certificate of occupancy approval, for other than one- and two-family dwellings. Building permits for above-grade combustible construction shall not be issued until all required water mains and hydrants are in service and a roadway capable of supporting twenty-five (25) tons is provided. In addition, the following requirements shall be met: (1) Fire alarm systems. All required fire alarm systems not connected to an approved central station alarm or a constantly attended location on premises shall display a durable, readily visible sign at each manual initiating device which reads: "THIS ALARM DOES NOT NOTIFY THE FIRE DEPARTMENT—TO REPORT A FIRE CALL 911." (a) Modifications of existing fire alarm systems and new fire alarm systems must be reviewed and inspected by the Fire Department, and may be required, in the discretion of the Fire Official per applicable NFPA standards requiring third party certification, to be UL Certificated. (2) Key box. When access to, or within, a structure is unduly difficult because of secured openings or where immediate access is necessary for life saving or firefighting purposes, the fire department may require a key box to be installed in an accessible location. The key box shall be a type approved by the fire department and shall contain keys to gain necessary access as may be required by the fire department. The key box may be provided with a tamper or breaking and entering alarm. (3) Addresses. All buildings are required to meet the city's property identification ordinance (See Article VI of Chapter 7). In multiple-family residential developments with three (3) or more buildings, a building number must also be posted. The numbers shall be sequential and a minimum of twelve (12) inches in height. They shall be posted a minimum of fifteen (15) feet above finish grade (or as high as possible) and be clearly visible from the adjacent roadway. Locations for all addresses and building numbers shall be approved by the fire department. (4) Fire suppression systems. In multiple story buildings, provide floor control valves with water-flow and tamper switches for each floor. In buildings equipped with an automatic fire suppression system, provide an outside audio visual device over the fire department connection.
(Ord. No. C-40-88, § 5, 8-15-88; Ord. No. C-8-98, § 4, 3-30-98; Ord. No. C-5-05, § 1, 4-11-05)
Ask a question about Farmington Hills law
Corpus searches the Farmington Hills sections it holds and shows the ones that match, with their citations. Free, no sign-in.