For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 33-60.6 — General regulations of Oakland County drain commissioner sewage disposal system

Code of Ordinances of the City of Farmington Hills, Michigan (Codified through Ordinance No. C-9-2025, adopted October 27, 2025. (Supp. No. 36)) · Farmington Hills Code of Ordinances § 33-60.6

Corpus is an independent public-information project, not the official City of Farmington Hills website. Stable reference: corpuslaw.us/code/4569a787-5f38-4263-bd4f-cf615cfa2d26

Sec. 33-60.6. - General regulations of Oakland County drain commissioner sewage disposal system.

(A) Introductory Statement: This section sets forth the procedures and regulations governing the granting of permits to connect into the Twelve Towns Relief Drains directly and to all other county drains that are tributary directly or indirectly to the facilities under the jurisdiction of the Southeastern Oakland County Sewage Disposal System. (B) General Provisions: (1) Each municipality is requested to furnish an up-to-date plan of its sewerage system. Plans should include the location, size and direction of flow in all existing sewers. Sewers should be identified as separated or combined. Pumping stations, flow regulation and diversion structure should be shown. (2) Plans for laterals shall be submitted in the name of the municipality by the municipal officials or a firm of consulting engineers officially authorized to do so. Generally, this authority will be vested in the city engineer or a single firm of consulting engineers retained as the city engineer. All plans submitted to this office shall bear the signature of the above designated official. (3) A letter requesting the approval of plans by the Oakland County Drain Commissioner's Office and the Water Quality Division of the Michigan Department of Natural Resources (formerly known as the Michigan Health Department) shall be addressed to the Oakland County Drain Commissioner and shall be accompanied by a minimum of five (5) sets of plans. Upon approval of the plans, the drain commissioner's office will retain one (1) set and forward the remaining sets to the Michigan Department of Natural Resources, along with a letter requesting their approval. Copies of this letter will be sent to the applicant municipality and the consulting engineer. The Michigan Department of Natural Resources, upon their approval of the plans, will return at least three (3) sets of approved plans bearing the construction permit number to the applicant municipality. The applicant municipality will keep one (1) set, send one (1) set to the Oakland County Drain Commissioner and send one (1) set to the consulting engineer. In the event that the applicant municipality or consulting engineer require an extra set of approved plans, additional sets shall be included with the initial request for approval. (4) Plans submitted to this office for review must meet the following requirements: (a) General location plan which shows the relationship to existing sewerage facilities, including outlet sewer interceptors, pumping stations, etc. (b) Detail plan and profile drawings along with criteria of hydraulic design (storm frequency, line capacity, line velocities, tributary areas, etc.). (c) Material and construction standards, regular and special. (d) Desirable scale and size for plan and profile drawings are: 1. Horizontal scale: 1″ = 100′, 1″ = 50′ 2. Vertical scale: 1″ = 10′, 1″ = 5′ 3. Plan size: 24″ × 36″ (C) Regulations Governing Connections in Combined Sewer Areas (Including Twelve Towns Relief Drains and County Combined Drains Tributary Thereto): (1) A connection permit must be obtained prior to connection from the Oakland County Drain Commissioner's Office, One Public Works Drive, Pontiac, Michigan 48054(858-0958). A legal description of the property to be served by the connection is required. (2) The fee as determined by the drain commissioner for connection permits shall be one hundred fifty dollars ($150.00), which is to cover the cost of the inspection of the tap. (3) The connection to the county drain will be made under the supervision of an inspector from the drain commissioner's office in accordance with approved plans of said connection. (4) A minimum of twenty-four (24) hours' notice (excluding Saturday, Sunday and holidays) must be given prior to tap to enable this office to arrange for inspection. (5) Requests for inspection shall be directed to the technician charged with the responsibility of permit issuance (858-0978). (6) All lines connected to county drains shall be clean (free from silt, dirt, debris, etc.). (7) Yard drains, catchbasins, downspouts, weep tile, perimeter drains or other structures used for the collection and conveyance of stormwater will be permitted to outlet into the county combined drains, provided said properties lie within said combined drainage district. (8) The contractor, during the construction of a lateral, shall install a suitable bulkhead to prevent sand, silt, dirt or other debris from entering the county drain. Upon work completion and removal of any debris that may have collected, the contractor shall contact the inspection office for permission to remove the bulkhead. (9) A connection from any industrial plant or facility using chemical processes shall be provided with a readily available sampling point (manhole or equivalent). (10) All wastes discharged into county drains shall meet the standards as specified in the current Detroit ordinance governing domestic and industrial wastes. (D) Regulations to Prevent the Discharge of Stormwater and Groundwater Into the Southeastern System From Those Areas Lying Outside the Designated Combined Sewer Area: (1) Sanitary sewers. All sanitary sewer systems [2] (lying in these areas of the S.O.C.S.D.S. district, designated as separated) to be connected directly or indirectly into the intercepting sewer or sewers of the S.O.C.S.D.S. prior to connection shall meet the following requirements: (a) A connection permit shall be obtained by the owner or contractor from the Oakland County Drain Commissioner's Office. Said connection permit shall show the location of the work, the extent of the work, information regarding the contractor, the owner and the engineer, the scheduled date of infiltration test and any other pertinent information as shall be determined necessary by the Oakland County Drain Commissioner. A fee shall be charged for said permit to cover the cost of inspection of the connection and system connected. (b) All sewer systems shall be subjected to infiltration, air or exfiltration tests or a combination thereof in accordance with the following requirements prior to acceptance of the system by the Oakland County Drain Commissioner's Office. 1. Infiltration test: a. All sewers over 24-inch diameter shall be subjected to infiltration tests. All sewers of 24-inch diameter or smaller, where the groundwater level above the top of the sewer is over seven (7) feet, shall be subjected to an infiltration test. b. Maximum allowable infiltration shall not exceed two hundred fifty (250) gallons per inch of diameter per mile of pipe per twenty-four (24) hours for the overall project. Maximum allowable infiltration shall not exceed five hundred (500) gallons per inch of diameter per mile of pipe per twenty-four (24) hours for any individual run between manholes. 2. Air test or exfiltration test. a. All sewers of 24-inch diameter or less, where the groundwater level above the top of the sewer is seven (7) feet or less, shall be subjected to air tests or exfiltration tests. b. For exfiltration tests the internal water level shall be equal to the external water level plus seven (7) feet, as measured from the top of pipe. The allowable exfiltration rate shall be the same as that permitted from infiltration. c. The procedure for air testing of sewers shall be as follows: The sewer line shall be tested in increments between manholes. The line shall be cleaned and plugged at each manhole. Such plugs shall be designed to hold against the test pressure and shall provide an airtight seal. One (1) of the plugs shall have an orifice through which air can be introduced into the sewer. An air supply line shall be connected to the orifice. The air supply line shall be fitted with suitable control valves and a pressure gauge for continually measuring the air pressure in the sewer. The pressure gauge shall have a minimum diameter of three and one-half (3½) inches and a range of zero (0) to ten (10) pounds per square inch gauge (PSIG). The gauge shall have minimum divisions of 0.10 PSIG and an accuracy of 0.04 PSIG. d. The sewer shall be pressurized to four (4) PSIG greater than the greatest back pressure caused by groundwater over the top of the sewer pipe. At least two (2) minutes shall be allowed for the air pressure to stabilize between three and one-half (3½) and four (4) PSIG. If necessary, air shall be added to the sewer to maintain a pressure of three and one-half (3½) PSIG or greater. e. After the stabilization period, the air supply control valve shall be closed so that no more air will enter the sewer. The sewer air pressure shall be noted and timing for the test begun. The test shall not begin if the air pressure is less than three and one-half (3½) PSIG or such other pressure as is necessary to compensate for groundwater level. f. The time required for the air pressure to decrease one (1) PSIG during the test shall not be less than the time shown in the "Oakland County Drain Commissioner's Air Test Tables." g. Manholes on sewers to be subjected to air tests shall be equipped with a one-half-inch diameter galvanized capped pipe nipple extending through the manhole three (3) inches into the manhole wall and at an elevation equal to the top of the sewer pipe. Prior to the air test, the groundwater elevation shall be determined by blowing air through the pipe nipple to clear it and then connecting a clear plastic tube to the pipe nipple. The tube shall be suspended vertically in the manhole and the groundwater elevation determined by observing the water level in the tube. The air test pressure shall be adjusted to compensate for the maximum groundwater level above the top of the sewer pipe to be tested. After all tests are performed and the sewer is ready for final acceptance, the pipe nipple shall be plugged in an acceptable manner. h. If a sewer fails to pass any of the previously described tests, the contractor shall determine the location of the leaks, repair them and retest the sewer. The tests shall be repeated until satisfactory results are obtained. i. All visible leaks and cracks shall be repaired regardless of test results. (2) Stormwater and groundwater control: (a) Yard drains, patio drains, catchbasins, downspouts, weep tile, perimeter and footing drains or any other structure used for the collection and conveyance of stormwater and/or groundwater shall not be permitted to discharge into any sanitary sewer connected directly or indirectly to the county system, except as provided below. (b) Perimeter and footing drains from buildings existing before July 23, 1981, shall not be required to disconnect from the sanitary sewer system; provided, that federal, state or local law or regulation does not require, or may not require subsequent to the adoption of these standards and regulations, the disconnection of such perimeter and footing drains. (c) The crock to iron joint shall be sealed by approved flexible adaptor fittings such as those manufactured by Fernco Joint Sealer Company or as approved by the Oakland County Drain Commissioner's Office. The iron pipe inside the building shall be plugged and leaded and remain plugged and watertight until such time as the plumbing is carried on to the first floor, the basement backfilled and the roof is on the building, thereby providing that no water from the excavated basement will enter the sanitary sewer. (3) Building sewers. House connection sewer from the lateral sewer in the street or easement five (5) feet from house shall be: (a) Six-inch diameter extra strength vitrified sewer pipe, manufactured in accordance with current NCPI Designation ER 4-67 Standards, or equal, with drain commissioner-approved premium joint; (b) Six-inch diameter ABS plastic solid wall sewer pipe conforming to ASTM designation D-2751 SDR 35 or 23.5; or (c) Six-inch diameter PVC plastic solid wall sewer pipe conforming to ASTM designation ASTM D-3034 SDR 35 or ASTM D-2665 Schedule 40. (d) Other pipes and joints as may be approved by the Oakland County Drain Commissioner. House connection sewers should be six-inch minimum diameter; however, four-inch pipe of comparable strength and joint material may be used if permitted by the local unit of government. All joints shall be tight and when tested for infiltration shall not exceed five hundred (500) U.S. gallons per inch of diameter, per mile, per twenty-four (24) hours. The crock to iron joint shall be sealed by an approved bituminous filler, enclosed in concrete to provide a watertight seal. The iron pipe inside the building shall be plugged and leaded and remain plugged and watertight until such time as the plumbing is carried on to the first floor, thereby providing that no water from the excavated basement will enter the sanitary sewer. The municipality shall issue tap permits for each structure that is connected into the S.O.C.S.D.S. and shall be responsible to see that the above specifications pertinent to materials and installations are followed. (4) Flow metering equipment. The S.O.C.S.D.S., through their agent, the drain commissioner, shall, at his option, be permitted to set up and operate flow metering equipment to gauge sanitary flow, either on a temporary or permanent basis, in any sanitary sewer lying within the "separated areas." (5) Review and approval of plans and specifications. Plans and specifications covering the construction of all new sewers, both combined and sanitary (separate), lying within the S.O.C.S.D.S. service area shall be submitted to the office of the Oakland County Drain Commissioner for review and approval prior to construction. (6) Quality of waste. The quality of domestic and industrial waste outletted into the S.O.C.S.D.S. facilities shall conform to the current City of Detroit ordinance pertinent to domestic and industrial wastes. It is the contractual obligation of the municipality, reference Section 16 of contract with county, to use S.O.C.S.D.S. facilities to enforce these standards. (7) Compliance with local rules and regulations. No requirements of the S.O.C.S.D.S. or permits issued hereunder by said system through their agent, the Oakland County Drain Commissioner, shall relieve the property owner of complying with all the rules and regulations of the local unit of government wherein such property is located where such are not in conflict with requirements of the S.O.C.S.D.S. (8) Compliance with construction specification. All sewer construction shall comply with the general specifications of the Oakland County Drain Commissioner; copies of said specifications may be obtained from the office of the drain commissioner.

(Ord. No. C-19-89, § 6, 11-20-89)

Ask a question about Farmington Hills law

Corpus searches the Farmington Hills sections it holds and shows the ones that match, with their citations. Free, no sign-in.