§ 9.835 — Smoke Alarm Power Source
Code of the City of Grand Rapids, Michigan (Supp. No. 70: codified through Ordinance No. 2026-08, enacted April 14, 2026) · Grand Rapids City Code § 9.835
Corpus is an independent public-information project, not the official City of Grand Rapids website. Stable reference: corpuslaw.us/code/eecfcb3e-799e-48cf-89d7-9e8b7f04b01d
Sec. 9.835. - Smoke Alarm Power Source.
The primary power source for a required smoke alarm shall be household alternating current (AC) or a lithium battery with a functional life expectancy of ten (10) years or more. When a hard-wired household alternating current (AC) alarm is installed, there shall also be lithium battery automatic backup in the event of a failure or interruption of the AC primary power source. When an alarm with a lithium battery with a life expectancy of ten (10) years or more is installed as the primary power source, the alarm unit shall be one in which the battery is sealed within the unit and cannot be removed from the unit without serious damage to the unit. No seriously damaged or inoperative smoke alarm shall meet the requirements of this Article. Mass-market battery powered units, including those powered by alkaline batteries, capable of being used in other consumer applications or those powered by lithium batteries not sealed within the unit do not comply with the requirements of this provision for required alarms. Additional smoke alarms which are installed but are not required by this Article may be powered by alternating current or a battery.
(Ord. No. 99-62, § 1, 11-9-99)