§ 20.05 — General standards
Code of Ordinances of the City of Kentwood, Michigan (Codified through Ordinance No. 6-26, adopted June 2, 2026. (Supp. No. 18)) · Kentwood Code of Ordinances § 20.05
Corpus is an independent public-information project, not the official City of Kentwood website. Stable reference: corpuslaw.us/code/d603f02f-d814-41dd-8f89-74bae48a7271
Section 20.05. - General standards.
A. Unless otherwise permitted within section 20.06 or 20.08, only shielded fixtures as defined in section 20.03 may be used. Any interior light fixtures that are deemed to be causing glare and therefore not meeting the purpose or intent of this ordinance shall be shielded to prevent glare at the property line. B. Decorative fixtures using lamps with low wattages do not have to be shielded; these include incandescent lamps of 60 watts or less, glass tubes filled with neon, argon and krypton and any other light source of 50 watts or less. Decorative luminaries above 50 watts shall have internal and/or external reflectors that shield the light source. [image omitted; see the official code] Reflector C. It is recognized that metal halide and fluorescent lamps are superior lights for color and object recognition when compared to other lamp types such as low and high pressure sodium or mercury vapor. Therefore, use of metal halide and fluorescent lamps is highly encouraged over low or high pressure sodium or mercury vapor lamps. It is also recognized that as the lighting industry develops, new lamp types are occasionally introduced that may have similar characteristics as the currently preferred types that may also be desirable for use in outdoor lighting. D. The intensity of light on a site shall not exceed three-tenths (0.3) footcandles at any property line that abuts a residential zoned property or 0.5 footcandles for any other zoned property. To encourage energy conservation, it is recognized that some commercial, office and industrial sites may desire to share fixtures along property lines or allow light to trespass onto adjacent sites. Such light trespass shall be allowable if a letter of permission is provided by the property owner where the light trespass is occurring and if the footcandle intensities meet the intent and purpose of this ordinance. E. All exterior lighting shall be designed in a consistent and coordinated manner for the entire site. F. Indirect internal illumination of signs and canopies is permitted provided a maximum 125 watt bulb is utilized and the transmittal surface is of a color and material that effectively shields lamps.
Ask a question about Kentwood law
Corpus searches the Kentwood sections it holds and shows the ones that match, with their citations. Free, no sign-in.
