Section 20.06. - Lighting intensity and uniformity standards.

The following lighting intensity and uniformity standards shall be used in designing an outdoor lighting plan as required within section 20.04. Light Use | Required Average to Minimum Uniformity Ratio 2 | Required Minimum Footcandle Reading 2 | Maximum Allowable Average Illumination 2 | Maximum Allowable Footcandle Reading 2 Outdoor Display 28th Street or Broadmoor Avenue | 4:1 | ———— | 5.0 footcandles | Front ROW no more Than 20 footcandles; Other ROWs no more Than Ten footcandles All other areas | Front Row no more Than Ten footcandles; Other Rows no more Than Five footcandles Pump Islands of Gasoline Stations | 4:1 | Between 1.0 and 5.0 | 22.0 footcandles Building Facades and Externally Illuminated Signs 3 | ———— Bright Surroundings and Light Surfaces | 5 Bright Surroundings and Medium Light Surfaces | 7 Bright Surroundings and Dark Surfaces | ———— | ———— | 10 | ———— Dark Surroundings and Light Surfaces | 2 Dark Surroundings and Medium Light Surfaces | 3 Dark Surroundings and Medium Dark Surfaces | 4 Dark Surroundings and Dark Surfaces | 5 Building Entrances | 4:1 | ———— | 5.0 Footcandles Active | ———— 1.0 Footcandles Inactive Parking Lots 4 | 4:1 | Between 0.2 and 0.7 | ———— | ———— Security Lighting | ———— | ———— | 1.5 Footcandles | ———— Exterior Recreational Facilities | See Subsection "A" Footnotes to chart: 1 The above statistics should only be applied to the area of each site devoted to the particular use. For example, a gas station/restaurant combination may have an area dedicated as a parking lot for the restaurant patrons and in addition have a pump island canopy. In this scenario two sets of statistics would need to be generated; one set for the parking lot and the other set for the canopy area. 2 Measurements for average to minimum uniformity ratio, required minimum footcandle reading, maximum allowable average illumination and maximum allowable footcandle reading shall be generated at the surface intended to be illuminated; e.g., pavement or area surface. These statistics shall be provided for areas where vehicular and pedestrian movement is provided for and other areas as necessary to show compliance with standards. 3 Building facades and signs shall not be illuminated if they are of glass, polished metal or other glossy surface including painted surfaces. Building facades shall also not be entirely illuminated, illumination shall be for architectural ornament and/or the illumination of small areas for visibility and security. For spotlight fixtures, no less than 90 percent of the light beam must be concentrated on the surface intended to be illuminated. For fixtures mounted directly to a wall surface or sign, external shields or dark colored nonreflective surface materials or other appropriate methods shall be used to minimize reflectance glare. 4 The maximum height of parking lot light fixtures shall be 20 feet when within 150 feet of a residential zone or public or private roadway, fixture heights may be as high as 25 feet on commercial, office and industrial sites when not within 150 feet of a residential zone or public or private roadway. For large developments such as a regional mall, the zoning administrator may approve fixtures mounted as high as 35 feet. A. Exterior recreational facilities. For exterior recreational facilities, sufficient information must be submitted in addition to that required in section 20.04 that demonstrates that the location, selection and aiming of all lighting fixtures will focus light on the playing areas, minimize glare and visibility from adjacent and nearby properties and roadways and minimize sky glow. A written explanation and statements shall be supplied explaining why locations, fixtures types, intensities, orientation of fixtures and other decisions were made. Lighting of sports facilities shall not be operated except during and turned off no later than 45 minutes after the event is over. B. Uses not specifically listed. For uses not specifically listed within this subsection, but determined to be of a type, use and or intensity that may be detrimental to achieving the purpose of this ordinance, the zoning administrator, depending on the purpose of the lighting, shall classify lighting into one of the categories contained in section 20.06. An applicant may appeal an initial classification to the zoning administrator, in writing, detailing why more intense lighting or less lighting is necessary. The zoning administrator shall either approve or deny the appeal based on whether or not sufficient justification has been submitted and whether the proposal meets the intent of city ordinances. Final determinations of the zoning administrator may be appealed to the zoning board of appeals.

Ask a question about Kentwood law

Corpus searches the Kentwood sections it holds and shows the ones that match, with their citations. Free, no sign-in.