For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 1046.14 — Monitoring facilities and techniques

Code of Ordinances of the City of Lansing, Michigan (Codified through Ordinance No. 1343, adopted October 27, 2025 (Supp. No. 64)) · Lansing Codified Ordinances § 1046.14

Corpus is an independent public-information project, not the official City of Lansing website. Stable reference: corpuslaw.us/code/4a2e4bb7-bbd8-41d3-a46d-01daf7e41290

1046.14. - Monitoring facilities and techniques.

(a) The City may require to be provided and operated, at a user's own expense, monitoring facilities to allow inspection, sampling and flow measurement of the building sewer and/or internal drainage systems. The monitoring facility should normally be situated on the user's premises, but the City may, when such a location would be impractical or cause undue hardship on the user, allow the facility to be constructed in a public street or sidewalk area and located so that it will not be obstructed by landscaping or parked vehicles. There shall be ample room in or near such sampling manhole or facility to allow accurate sampling and preparation of samples for analysis. The facility, sampling and measuring equipment shall be maintained at all times in a safe and proper operating condition at the expense of the user. Whether constructed on public or private property, sampling and monitoring facilities shall be provided in accordance with plans and specifications submitted to and approved by the City and all applicable local construction standards and specifications. When required, construction of such facilities shall be completed within ninety days following written notification by the City. (b) All wastewater samples must be representative of the user's discharge. Wastewater monitoring and flow measurement facilities shall be properly operated, kept clean, and maintained in good working order at all times. The failure of a user to keep its monitoring facility in good working order shall not be grounds for the user to claim that sample results are unrepresentative of its discharge. (c) All sampling and analytical testing shall be in accordance with protocols, including appropriate preservation, specified in 40 CFR Part 136 and appropriate USEPA guidance. Where such protocols and guidance do not include a given pollutant, the user may apply methods subject to prior acceptance of the City. (d) For composite samples, the user shall use a flow-proportional sampling technique unless an alternate time-based or grab-based sampling technique is authorized by the Director. The user seeking an alternate sampling technique shall submit a request to the City in writing, and shall have the burden of demonstrating that the alternate sampling technique will be representative of the discharge. The decision whether to allow an alternate sampling technique will be at the Director's discretion, and the basis for this decision will be documented in the City's file for that user. (e) Grab samples shall be used for assessing compliance of oil and grease, temperature, pH, cyanide, total phenols, sulfides, and volatile organic compounds. For compliance reports, the user shall collect the number of grab samples necessary to properly assess its compliance with applicable pretreatment standards and requirements except as follows: for sampling associated with a 90-day compliance report or baseline monitoring report, a minimum of four daily grab samples must be used for pH, cyanide, total phenols, oil and grease, sulfide, and volatile organic compounds where historical sampling data does not exist; where historical sampling data does exist, the Director may authorize a lower number of samples. The user may use multiple grab samples for sampling associated with a 90-day compliance report or baseline monitoring report provided they are collected during a 24-hour period and composited prior to the analysis according to the following basis: (i) Composited in the field or the laboratory for cyanide, total phenols, and sulfides; (ii) Composited only in the laboratory for volatile organics and oil and grease; and (iii) Composited as authorized by the Director for other parameters.

(Ord. No. 698, 4-8-85; Ord. No. 1175, § 1, 10-10-11)

Ask a question about Lansing law

Corpus searches the Lansing sections it holds and shows the ones that match, with their citations. Free, no sign-in.