For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 102-527 — Permit application

Code of Ordinances of the City of Rochester Hills, Michigan (Codified through Ordinance No. 203, enacted August 24, 2026 (Supp. No. 54)) · Rochester Hills Code of Ordinances § 102-527

Corpus is an independent public-information project, not the official City of Rochester Hills website. Stable reference: corpuslaw.us/code/e6697b97-95db-410e-9183-2b2a5573c766

Sec. 102-527. - Permit application.

(a) Application or reapplication. The department may require any user to complete a questionnaire and/or a permit application and to submit the same to the department for determining whether the industrial user is a significant user, or to determine changes in the wastewater discharges from a user's facility. Within 30 days of being so notified, a user shall comply with the department's request in the manner and form prescribed by the department. Failure of the department to so notify a user shall not relieve the user of the duty to obtain a permit as required by this article. (1) A user, which becomes subject to a new or revised National Categorical Pretreatment Standard, shall apply for a wastewater discharge permit within 90 days after the promulgation of the applicable National Categorical Pretreatment Standard, unless an earlier date is specified or required by 40 CFR 403.12(b). The existing user shall provide a permit application which includes all the information specified in this article. (2) A separate permit application shall be required for each separate facility. (3) Existing permittees shall apply for permit reissuance a minimum of 90 days prior to the expiration of existing permits on a form prescribed by the department. (b) Required information. In support of an application or reapplication for a wastewater discharge permit, the industrial user shall submit, in units and terms appropriate for evaluation, the following information: (1) Corporate or individual name, any assumed name(s), federal employer identification number, address, and location of the discharging facility; (2) Name and title of the authorized representative of the industrial user who shall have the authority to bind the industrial user financially and legally; (3) All SIC numbers of all processes at this location according to the Standard Industrial Classification manual, issued by the Executive Office of the President, Office of Management and Budget, 1987, as amended; (4) Actual or proposed wastewater constituents and characteristics for each parameter listed in the permit application form. Such parameters shall include those applicable pollutants having numeric limitations as enumerated in this article, those pollutants limited by National Categorical Pretreatment Standards regulations for applicable industries and any toxic pollutants known or suspected to be present in the discharge, regulated in the previous permit, or specifically requested by the Great Lakes Water Authority: a. For each parameter, the expected or experienced maximum and average concentrations during a one-year period shall be provided. b. For industries subject to National Categorical Pretreatment Standards or requirements, the data requested herein shall be separately shown for each categorical process waste stream. c. Combined waste streams proposed to be regulated by the combined waste stream formula shall also be identified. d. Sampling and analysis shall be performed in accordance with procedures established by the EPA pursuant to 33 USC 1314(g) and contained in 40 CFR Part 136, as amended. Where 40 CFR Part 136 does not include sampling or analytical techniques for the pollutants in question, sampling and analysis shall be performed using validated analytical methods approved by the administrator. (5) A listing and description of activities, facilities and plant processes on the premises. Those processes, which are subject to National Categorical Pretreatment Standards or requirements, shall be so designated. As pertains to paragraph (b)(4) of this section, identify which pollutants are associated with each process; (6) Restricted to only those pollutants referred to in paragraph (b)(4) of this section, a listing of raw materials and chemicals which are either used in the manufacturing process or could yield the pollutants referred to in paragraph (b)(4). Any user claiming immunity from having to provide such information for reasons of national security shall furnish acceptable proof of such immunity; (7) A description of typical daily and weekly operating cycles for each process in terms of starting and ending times for each of the seven days of the week: (8) The average and maximum 24-hour wastewater flow rates including, if any, daily, monthly and seasonal variations; a. Each national categorical process waste stream flow rate and the cooling water, sanitary water and stormwater flow rates separately for each connection to the POTW; and b. Each combined waste stream; (9) A drawing showing all sewer connections and sampling manholes by the size, location, elevation and points or places of discharges into the POTW; also a flow schematic showing which connections receive each National Categorical Process waste stream and which connections receive stormwater, sanitary water or cooling water; also show which lines handle each combined waste stream. This schematic shall be cross-referenced to the information furnished in paragraph (b)(8) of this section; (10) Each product produced by type, amount, process or processes and rate of production as pertains to processes subject to production based limits under the National Categorical Pretreatment Standards or requirements only; (11) A statement regarding whether or not the requirements of this article and of the National Categorical Pretreatment Standards and requirements are being met on a consistent basis and, if not, what additional operation and maintenance work and/or additional construction is required for the industrial user to meet the applicable standards and requirements. This statement shall be reviewed and signed by the authorized representative and, as appropriate, certified by a qualified professional; (12) Basic information on the program for the prevention of accidental discharges in accordance with the requirements of this article; (13) Proposed or actual hours of operation of each pretreatment system for each production process; (14) A schematic and description of each pretreatment facility which identifies whether each pretreatment facility is of the batch type or continuous process type; (15) If other than Great Lakes Water Authority potable water, the industrial user's source of intake water together with the types of usage and disposal method of each water source, and the estimated wastewater volumes from each source; (16) If additional construction and/or operation and maintenance procedures will be required to meet the requirements of this division and the National Categorical Pretreatment Standards, the shortest schedule by which the user will provide such additional construction and/or implement the required operation and maintenance procedures; (17) Identify whether the user has conducted a waste minimization assessment or audit of its operations in order to identify all feasible source reduction and recycling practices that may be employed to reduce or eliminate the generation of pollutants and other waste at the facility; and (18) Any other information as may reasonably be required to prepare and process a wastewater discharge permit.

(Ord. No. 537, § 1, 7-13-2009; Ord. No. 624, § 43, 12-14-2020)

Ask a question about Rochester Hills law

Corpus searches the Rochester Hills sections it holds and shows the ones that match, with their citations. Free, no sign-in.