§ 35-101 — Rear yard storm drainage
Code of Ordinances of the City of Warren, Michigan (Supp. No. 102: codified through Ordinance No. 80-840, adopted October 28, 2025) · Warren City Code § 35-101
Corpus is an independent public-information project, not the official City of Warren website. Stable reference: corpuslaw.us/code/3214095b-8ec8-4fe8-a41a-0d78f429a625
Sec. 35-101. - Rear yard storm drainage.
(a) The developer shall provide for adequate and safe disposal of all rear yard storm water. (b) Rear yard storm drainage pipe shall be provided in the rear yard of each lot with suitable catch basins provided at intervals of four hundred eighty (480) feet in areas of sixty-foot lots, or the equivalent of four (4) lots each direction of flow for a total of eight (8) lots between catch basins in areas of lots exceeding sixty (60) feet in width, at the discretion of the city engineer. All such construction shall be under the supervision of the director of public service. (c) All tile drains shall comply with the following specifications: (1) Six (6) inches C700 bell and spigot or perforated P.V.C. for ready entrance of water. The pipe shall be laid in an accommodating trench with proper grades and horizontal bearing with proper bell holes. (2) The trench shall be filled with uniform gravel at one-half inch, three-fourths inch, and not to exceed one (1) inch to a point about six (6) inches below the top. This top six (6) inches to be filled with dirt to accommodate grass or sod as a part of the six (6) inches.
(Code 1967, § 6-540; Ord. No. 80-340, § 38, 6-9-87)
Ask a question about Warren law
Corpus searches the Warren sections it holds and shows the ones that match, with their citations. Free, no sign-in.