§ 35-102 — Sanitary sewers
Code of Ordinances of the City of Warren, Michigan (Supp. No. 102: codified through Ordinance No. 80-840, adopted October 28, 2025) · Warren City Code § 35-102
Corpus is an independent public-information project, not the official City of Warren website. Stable reference: corpuslaw.us/code/74542e9e-785a-45fc-84f1-2e1bd28d9c9c
Sec. 35-102. - Sanitary sewers.
(a) The developer shall provide a complete sanitary sewer system discharging into an outlet as approved by the director of public service. (b) The construction of the sanitary sewer system for the entire subdivision shall be done in accordance with standard specifications on file in the office of the director of public service. (c) Sanitary sewers shall be designed to run half full, be connected on center lines and the velocity in same limited not to exceed five (5) feet per second. Sanitary sewers shall be capable of carrying four hundred twenty-five (425) gallons per capita per day. Wherein syphons or clean-outs become involved, the design should be handled on an individual basis subject to the complete approval of the city engineer.
(Code 1967, § 6-541; Ord. No. 80-340, § 39, 6-9-87)