§ 4.61 — Standards and conditions
Code of Ordinances of the City of Warren, Michigan (Supp. No. 102: codified through Ordinance No. 80-840, adopted October 28, 2025) · Warren City Code § 4.61
Corpus is an independent public-information project, not the official City of Warren website. Stable reference: corpuslaw.us/code/51d8ea4e-4a65-4e8f-98c8-a72b7ef67d91
Section 4.61 - Standards and conditions.
1. Setback. The following minimum separation requirements shall apply to all Towers: a. Towers shall be set back 200 feet from any R-1-A, R-1-B, R-1-C, R-2, R-3 and R-3-A district property boundary line, or from private or public day-care center or educational institution, excluding trade schools or colleges. the distance shall be measured from the base of the tower or supporting structure. b. Towers shall be setback to the greater of 150 feet or a distance equal to 125 percent of the height of the supporting structure, whichever is greater, to the district boundary line of all other districts, unless there is a day care or educational institution in such district, in which case subsection (a) shall apply. c. Notwithstanding the above, the separation between the Tower and the adjoining property lines shall be no less than the radius of the fall zone for the support structure in the event of total collapse, including any falling debris, antennae or other equipment, or fire, based upon an engineering certification. A greater setback will required based upon a Fall Zone exceeding the separation requirements in subsection (a) and (b) above. 2. Height. The maximum height of any Tower, including lightening rod, antenna or other accessory equipment, is 150 feet. 3. Co-location. The tower shall be designed to accommodate future collocations of at least three platforms (accommodating three carriers). 4. Access. Adequate access to wireless communications equipment and to the support structure, for the maintenance of the facility and equipment and for emergency vehicles. 5. Emissions. The equipment shall not radiate radio frequency emissions that exceed the thresholds of the FCC or FAA. 6. No Hazardous substance. No Hazardous Substance shall be leaked or released from the Tower or equipment, and full compliance with federal or state guidelines. 7. Signs. Emergency notification signs shall be posted on the site identifying the owner of the facility and an emergency response contact information. No other signs are permitted. 8. No artificial illumination unless required by federal or state regulations or by the planning commission. If required by law, the lighting alternatives and design must result in the least disturbance to the surrounding properties. 9. The structure shall be placed in an area which would not require the removal of trees or natural features. If a tree is removed, a tree must be planted elsewhere on the property. 10. Maintenance, construction, schedule, colors, screening, landscaping, buffers, design, and emissions must conform to the reports, representations made or submitted with the site plan application and conditions imposed by the Planning Commission or Planning Director, if administratively approved. 11. The tower and equipment must be maintained and operated in good working order in compliance with the regulations of the FAA and FCC, and other applicable governmental and regulatory agencies. All registrations and licenses required by law or regulation shall be maintained and kept in good standing. 12. Colors and design shall be compatible with the surrounding area. The tower and all accessory equipment shall be solid, neutral colors, as determined by the Planning Commission. 13. Antenna towers shall comply with the setback standards for a structure in the zoning district for the parcel that may exceed the standard in section 4.61 (1). 14. A freestanding antenna tower (i.e. not mounted on a roof) shall not be located in any front yard. 15. All accessory structures must meet the minimum setback standards for accessory structures in the zoning district for the parcel and shall not be inhabited, used for vehicle storage or used for outdoor storage of any kind. 16. After construction, the Tower and associated antennae or equipment shall remain in continuous use and operation for a period of three months. The Tower Owner shall report to the City the non-use and whether re-use is expected within the ensuing three months. Any Tower or equipment that is not operated for a continuous period of six months shall be considered abandoned, and the Director of Public Service may order removal. 17. No Facility, antenna or antenna equipment or accessory equipment, shall interfere in any manner with current or future City or other governmental public safety communication or with any utilities, or the surrounding use of existing radios, televisions, or other electronic equipment.
(Ord. No. 30-1084, § 2, 7-9-24)
Ask a question about Warren law
Corpus searches the Warren sections it holds and shows the ones that match, with their citations. Free, no sign-in.