§ 11-101-19 — PUBLIC UTILITIES, RAILROADS, STREETS, AND BRIDGES
Lakeville, Minnesota Code of Ordinances (2026 S-14, code current through Ord. 1122, passed 4-20-2026) · Lakeville Code of Ordinances § 11-101-19
Corpus is an independent public-information project, not the official City of Lakeville website. Stable reference: corpuslaw.us/code/f3f0e804-4cb2-4f32-9218-bc4d075f1ec1
11-101-19: PUBLIC UTILITIES, RAILROADS, STREETS, AND BRIDGES:
A. Public Utilities: All public utilities and facilities such as gas, electrical, sewer, and water supply systems to be located in the floodplain shall be floodproofed in accordance with the state building code or elevated to above the regulatory flood protection elevation and comply with the following setbacks: 1. Where a watercourse has a sinuous flow pattern and a meander belt can be identified, the setback for new underground utilities shall be set back fifteen feet (15') from the outer edge of the meander belt. 2. Where a sinuous flow pattern and meander belt are not readily identifiable because of past channel alterations and/or the geomorphology of the channel, the setback established for new underground utilities shall provide for the potential for restoration and a sinuous flow pattern as follows: a. Where there are existing encroachments that limit full restoration of the watercourse to the meander widths appropriate for the watercourse type, the setback shall be fifteen feet (15') from the reasonably achievable restoration width as determined by the city engineer for the meander belt given the existing encroachments. b. Where full restoration is possible, the setback shall be fifteen feet (15') from a meander belt width defined as ten (10) times the bankfull channel width. The bankfull channel width of a stream, creek, or river is its width at bankfull stage; the water level in a watercourse where the flow just begins to leave the main channel and enter the active floodplain. c. An assessment of the watercourse type may be completed, and meander belt widths established according to the stream type, in place of using the above formula as approved by the city engineer. 3. Utilities that require reaching or crossing the watercourse, are exempted from this section provided the minimum impact alignment is used. B. Public Transportation Facilities: Railroad tracks, streets, and bridges to be located within the FW floodway and FF flood fringe districts shall comply with this chapter. All railroad tracks, streets, bridges, and major transportation facilities must be constructed at or above the regulatory flood protection elevation where failure or interruption of these transportation facilities would result in danger to the public health or safety or where such facilities are essential to the orderly functioning of the area. Local streets or minor railroads may be constructed at an elevation two feet (2') below the regulatory flood protection elevation where failure or interruption of transportation services would not endanger the public health or safety. C. On Site Sewage Treatment And Water Supply Systems: Where public utilities are not provided: 1) on site water supply systems must be designed to minimize or eliminate infiltration of floodwaters into the systems; and 2) new or replacement on site sewage treatment systems must be designed to minimize or eliminate infiltration of floodwaters into the systems and discharges from the systems into floodwaters and they shall not be subject to impairment or contamination during times of flooding. Any sewage treatment system designed in accordance with the state's current statewide standards for on site sewage treatment systems shall be determined to be in compliance with this chapter. (Ord. 883, 9-19-2011)
Ask a question about Lakeville law
Corpus searches the Lakeville sections it holds and shows the ones that match, with their citations. Free, no sign-in.