IX — RESIDENTIAL CODE
Code of Ordinances of the City of Lee's Summit, Missouri (Codified through Ordinance No. 10423, enacted July 14, 2026 (Supp. No. 56)), Lee's Summit, MO · 54 sections. Independent public-information project, not the official City of Lee's Summit website.
- § 7-900 — International Residential Code adopted
- § 7-901 — International Residential Code amended; Section R101.1. Title
- § 7-902 — International Residential Code amended; Section R103.1. Creation of agency
- § 7-903 — International Residential Code amended; Section R104.4. Right of entry
- § 7-904 — International Residential Code amended; Section R104.4.1 Warrant
- § 7-905 — International Building Code amended; Section 105.5. Expiration
- § 7-906 — International Residential Code amended; Section R110.3. Temporary occupancies
- § 7-907 — International Residential Code amended; Table R301.2. Climatic and geographic design criteria
- § 7-908 — International Residential Code amended; Section R302.5.1. Opening
- § 7-909 — International Residential Code amended; Section R304.1.1. Field treatment
- § 7-910 — International residential code amended; section R305.1.2. field treatment
- § 7-911 — International Residential Code amended; Section R309. Automatic fire sprinkler
- § 7-913 — International Residential Code amended; Section R309.1. Townhouse automatic sprinkler systems
- § 7-914 — International Residential Code amended; Section R309.2. One- and two-family dwellings automatic sprinkler systems
- § 7-915 — International Residential Code amended; Section R318.3.2. Floor elevations at other exterior doors
- § 7-916 — International Residential Code amended; Section R320.6. Grip size
- § 7-917 — International residential code amended; Section R328 Swimming pools, spas and hot tubs
- § 7-918 — International Residential Code amended; Section R401.3.1. Minimum standards
- § 7-919 — International Residential Code amended; Section R403.1.1.1. Footing reinforcement
- § 7-920 — International Residential Code amended; Section R403.1.1.2 Column pads
- § 7-921 — International Residential Code amended; Section R403.3. Frost protected shallow foundations
- § 7-922 — International Residential Code amended; Section R404.1.7. Backfill
- § 7-923 — International Residential Code amended; Section R405.1. Concrete and masonry foundations
- § 7-924 — International Residential Code amended; Section R506.3.5. Interior underslab drains
- § 7-925 — International Residential Code amended; Section R507.9.2. Lateral connection
- § 7-926 — International Residential Code amended; Section R602.6.1. Drilling and notching of the top plate
- § 7-927 — International Residential Code amended; Section R801.3. Roof drainage
- § 7-928 — International Residential Code amended; Section R902.1. Roof assemblies
- § 7-929 — International Residential Code amended; Section R908.1. General Materials
- § 7-930 — International Residential Code deleted; Chapter 11. Energy Efficiency
- § 7-931 — International Residential Code amended; Section G2414.4. Metallic tubing
- § 7-932 — International Residential Code amended; Section G2414.4.3. Copper or copper alloy tubing
- § 7-933 — International Residential Code amended; Section G2417.4.1. Test pressure
- § 7-934 — International Residential Code amended; Section P2503.4. Building sewer testing
- § 7-935 — International Residential Code deleted; Section P2503.5. Drain, Waste and Vent System Testing
- § 7-936 — International Residential Code deleted; Section P2503.6. Shower Liner Test
- § 7-937 — International Residential Code amended; Section P2503.7 Water-Supply System Testing
- § 7-938 — International Residential Code amended; Section P2601.2.1. Prohibited drainage and connections
- § 7-939 — International Residential Code amended; Section P2603.5.1. Sewer depth
- § 7-940 — International Residential Code amended; Section P2902.5.3. Lawn irrigation systems
- § 7-942 — International Residential Code amended; Section P2902.6.2. Protection of backflow preventers
- § 7-943 — International Residential Code amended; Section P3005.4.2. Building drain and sewer size and slope
- § 7-944 — International Residential Code amended; Section P3008.1. Backwater valves
- § 7-945 — International Residential Code amended; Section P3114.3. Where permitted
- § 7-946 — International Residential Code amended; Section E3601.6.2 Service disconnect location
- § 7-947 — International Residential Code deleted; Section E3601.8. Emergency disconnect
- § 7-948 — International Residential Code deleted; Section E3606.5. Surge protector
- § 7-949 — International Residential Code deleted; Section E3901.4.2. Island and peninsular countertop and work surfaces
- § 7-950 — International Residential Code amended; Section E3901.4.3. Receptacle outlet location
- § 7-951 — International Residential Code amended; Section E3902.2. Garage and accessory building receptacles
- § 7-952 — International Residential Code amended; Section E3902.5. Unfinished Basement receptacles
- § 7-953 — International Residential Code amended; Section E3902.11. Indoor damp and wet locations
- § 7-954 — International Residential Code amended; Section E3902.12. Specific appliance
- § 7-955 — International Residential Code amended; Section 3902.14. Outdoor outlets