For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 11.040 — Standards

Code of Ordinances of the City of Lee's Summit, Missouri (Codified through Ordinance No. 10423, enacted July 14, 2026 (Supp. No. 56)) · Lee's Summit Unified Development Ordinance § 11.040

Corpus is an independent public-information project, not the official City of Lee's Summit website. Stable reference: corpuslaw.us/code/e50f4032-39b5-44ef-afb7-fdced68fc96a

Sec. 11.040. - Standards.

A. General. 1. Federal and state regulations. All wind turbines shall meet or exceed current State and Federal standards and regulations including, without limitation: a. Applicable Federal Aviation Administration (FAA) regulations, including necessary approvals for installations close to airports. Any wind turbine proposed to be within 20,000 feet of the center of the existing airport runway is subject to a required review by the FAA to determine whether it is a hazard or obstruction to aviation users of the airport. b. RSMo 386.890, also known as the Net Metering and Easy Connection Act, which mandates that covered equipment conform to applicable safety, performance, interconnection, and reliability standards established by the National Electrical Code (NEC), the National Electrical Safety Code (NESC), the Institute of Electrical and Electronics Engineers (IEEE), Underwriters Laboratories (UL), and the Federal Energy Regulatory Commission. 2. Building Code compliance. All wind turbines shall meet or exceed the current standards expressed in the adopted International Family of Codes, as amended. 3. Utility connections. Reasonable efforts shall be made to locate utility connections from the wind facility underground, depending on appropriate soil conditions, shape, and topography of the site and any requirements of the utility provider. Electrical transformers for utility interconnections may be above ground if required by the utility provider. 4. Electrical wires. All electrical wires associated with a wind energy system shall be located underground except for those wires necessary to connect the wind generator to the tower wiring, the tower wiring to the disconnect junction box, and the grounding wires. 5. Self-supporting structures. All tower structures shall be of monopole construction unless attached to a structurally reinforced roof where such support is not warranted. No lattice structures shall be permitted. Towers requiring guy wire supports shall be limited to lots of one acre or more and the guy wires shall be setback from all property lines a minimum of ten feet. 6. Tower access. The supporting tower shall either be enclosed with a six-foot tall fence or the base of the tower shall not be climbable up to 12 feet above ground level. All access doors to the tower and electrical equipment shall be locked. 7. Safety shutdown. Each wind turbine shall be equipped with both manual and automatic overspeed controls to limit the rotational speed of the blade within the design limits of the rotor. Manual electrical and/or overspeed shutdown disconnect switches shall be provided and clearly labeled on the wind turbine structure. No wind turbine shall be permitted that lacks an automatic braking, furling, or feathering system to prevent uncontrolled rotation, overspeeding and excessive pressure on the tower structure, rotor blades, and turbine components. 8. Lighting. Wind turbines shall not be artificially lighted unless such lighting is required by the Federal Aviation Administration (FAA) or other applicable authority. Large wind facilities may utilize security lighting around the base of the tower or other structure associated with the wind turbine(s) if the lighting complies with Article 8, Division I, and no light is directed toward adjacent properties or rights-of-way. 9. Minimum blade clearance. The blade tip clearance for micro wind turbines shall, at its lowest point, have a ground clearance of not less than 15 feet. The minimum blade clearance for any other wind turbine shall be 30 feet. 10. Noise. The noise emitted from any wind turbine shall not exceed 55 dbA, as measured at the nearest property line, except during short-term events such as utility outages and severe windstorms. 11. Historic districts. WECS proposed for locations within any designated local historic district or for locations which will be visible from multiple points of a recognized historic district shall obtain a certificate of appropriateness. 12. Signage. Signs shall be limited to the manufacturer's or installer's identification, and appropriate warning signs (e.g. electrical hazard or high voltage) placed on the wind turbine tower(s), electrical equipment, and the wind turbine. Commercial advertising is strictly prohibited. 13. Color/finish. Wind turbines, exclusive of the towers, shall be painted a non-reflective, non-obtrusive color such as the manufacturer's default color option or a color that conforms to the environment and architecture of the community. Towers shall maintain galvanized steel, brushed aluminum or white finish, unless FAA standards require otherwise. B. Size specific. 1. Micro and small WECS. a. Location. All micro and small wind turbines shall be located in the rear yard only. Exceptions to this standard for small wind turbines may be reviewed as part of the special use permit application. b. Utility notification. No building permit for a micro or small WECS shall be issued until a copy of the utility company's approval for interconnection of a customer-owned generator has been provided. Off-grid systems shall be exempt. 2. Large/utility WECS. a. Soil. All new applications for large or utility scale wind turbines shall provide certification from a professional engineer registered in the State of Missouri that the soil and subsoil surface is capable of accepting the projected loads. b. Shadow/flicker. Large or utility scale wind turbines shall be sited in a manner that minimizes shadowing or flicker impacts. The applicant has the burden of proving that this effect does not have significant adverse impact on neighboring or adjacent uses and right-of-way through either siting or mitigation. c. Use of met towers. Met towers may be utilized for large or utility scale wind turbines only as approved by the Governing Body. The location, height, and length of time such structures are to be erected shall be provided as part of the application for preliminary development plan and special use permit. Table 11-1: Standards for Roof-Mounted Wind Turbines Turbine Size | Zoning District Permitted In | Maximum Height | Minimum Setback | How Permitted Micro Wind Turbines | PI-1 and PI-2 | Equal to ½ the building height | Equal to the height of the tower from all property lines and any buildings | Accessory Use Greater than ½ the building height | Special Use Permit Table 11-2: Standards for Free-Standing Wind Turbines Turbine Size | Zoning District Permitted In** | Minimum Lot Size | Maximum Height* | Minimum Setback | How Permitted Micro Wind Turbines | AG Thru RP-4 | < 1 acre | 40 feet | Equal to the height of the tower* from all property lines and any buildings | Conditional Use AG Thru RP-4 | 1 acre | 80 feet PO Thru PI-2 | 1 acre | 80 feet AG Thru RP-4 | 2 acres | 100 feet PO Thru PI-2 | 2 acres | 100 feet Small Wind Turbines | AG Thru RP-4 | 2 acres | 100 feet | 110% of the height of the tower* from any property line or above ground utilities | Conditional Use PO Thru PI-2 | 2 acres | 100 feet CP-1 Thru PI-2 | 3 acres | 120 feet Large/Utility Wind Turbines | AG, PI-1, PI-2 | 10 acres | N/A | 150% of the height of the tower* from any property line or above ground utilities | Special Use Permit *The height shall be measured from ground level (grade) to the top of the tower nacelle. **The size, height, and approval process for districts zoned PMIX shall be determined based upon the underlying uses within that district. C. Homeowners associations and common property. Table 11-3: Free-Standing Wind Turbines on Common Property Turbine Size | Zoning District Permitted In** | Maximum Height* | Minimum Setback | How Permitted Micro or Small Wind Turbines | AG Thru RP-4 | Determined per Special Use Permit | 110% of the height of the tower* from any property line or above ground utilities | Special Use Permit *The height shall be measured from ground level (grade) to the top of the tower nacelle. **The size, height, and approval process for districts zoned PMIX shall be determined based upon the underlying uses within that district.

Ask a question about Lee's Summit law

Corpus searches the Lee's Summit sections it holds and shows the ones that match, with their citations. Free, no sign-in.