§ 2.360 — Final development plans; applications—Contents and submission requirements
Code of Ordinances of the City of Lee's Summit, Missouri (Codified through Ordinance No. 10423, enacted July 14, 2026 (Supp. No. 56)) · Lee's Summit Unified Development Ordinance § 2.360
Corpus is an independent public-information project, not the official City of Lee's Summit website. Stable reference: corpuslaw.us/code/6245fdfb-8293-452c-91d8-534da2f80142
Sec. 2.360. - Final development plans; applications—Contents and submission requirements.
A. All general application requirements contained in Section 2.040.A. B. All plan submission requirements in Section 2.040.B. C. Contents. The proposed final development plan shall also include the following: 1. A legal description which accurately describes the limits of the property. 2. Area of land in square feet and acres. 3. Location and limits of the one percent annual chance flood, as set forth on the current FEMA maps with reference to the panel number. Elevations shall be provided if shown on the FEMA map. 4. Layout, number and approximate dimensions of lots and approximate lot areas. 5. Name, location, width, radii, centerline, and grade of streets and alleys, both public and private. 6. Location, width and limits of all existing and proposed sidewalks and public walkways. 7. Location and width of proposed easements. 8. Building setback lines from streets with dimensions. 9. Location and approximate dimensions of culverts and bridges. 10. Location of existing and proposed driveways, curb cuts, median breaks and turn lanes. 11. The location and size of all utility lines, including water, storm water, and sanitary sewers. 12. Final analysis of the capacity of the existing sanitary sewer receiving system. 13. Final water and sanitary sewer plans. 14. Appropriate water service demand data (including, but not limited to, planned land usage, densities of proposed development, pipe sizes, contours and fire hydrant layout) to allow for the preliminary analysis of the demand for water service if required by the City Engineer. 15. Final storm water collection, detention and erosion control plans. 16. Information (proposed size, nature and general location) on all proposed storm water management facilities and detention facilities. A final storm water report shall be submitted unless the storm water report requirement was waived by the City Engineer or there are no required revisions to the preliminary storm water report. All storm water reports shall include: a. Current and proposed land use assumptions, b. Identification of the watershed in which the project is located, c. Identification of offsite drainage areas, d. Surrounding property information, e. Any other pertinent information about the site which may influence storm water runoff, f. Proposed storm water facilities, g. The downstream effects of the development, h. Calculations for the 100 percent, ten percent, and one percent storms. All calculations must be submitted with the report; a summary table is not acceptable, i. If the storm water report indicates that detention is not required, supporting calculations evaluating the downstream effects must be provided, j. All reports shall be signed and sealed by a professional engineer registered in the State of Missouri. 17. Location and size of proposed open space for public use proposed to be dedicated or reserved and any conditions of such dedication or reservation; parks, playgrounds, churches, or school sites or other special uses of land to be considered for public use, or to be reserved by deed or covenant for the use of all property owners in the subdivision. 18. Location and dimensions of all parking spaces, accessible spaces, accessible routes, drive aisles, driveways, and curbs. 19. Finished grades showing one-foot contours for the entire site (2-foot contour intervals may be allowed by the Director, depending on the site). 20. All proposed and existing adjacent public street rights-of-way with centerline location. 21. All proposed and existing adjacent public street and public drive locations, widths, curb cuts and radii. 22. Sufficient dimensions to indicate relationship between buildings, property lines, parking areas and other elements of the plan. 23. Location of all required building and parking setbacks. 24. Location, dimensions, number of stories and area in square feet of all proposed buildings. 25. The location of all oil and/or gas wells within the subject property. 26. Limits, location, size and material to be used in all proposed retaining walls. 27. Location and dimensions of all driveways, parking lots, parking stalls, aisles, loading and service areas and docks. 28. Location, height, intensity and type of outside lighting fixtures for buildings and parking lots. 29. Photometric diagram indicating the foot candle levels throughout the site and at the property lines. 30. The manufacturer's specification sheets for proposed exterior lighting to include both parking lot pole mounted and wall mounted fixtures. The specification sheets shall indicate the exact fixture to be used. 31. Location, size, and type of material to be used in all screening of ground mounted mechanical equipment. 32. The manufacturer's specification sheets for proposed mechanical equipment to be used. 33. Location, size, and type of material of all proposed monument or freestanding signs. 34. The location of adjacent developments, alignment and location of existing public and private driveways and streets, medians, and public and semi-public easements. 35. Locations of existing and proposed fire hydrants. 36. Sight triangles. (See Article 8, Division I.) D. Exterior building elevations. 1. Elevations of all sides of proposed buildings including notation indicating building materials to be used on exteriors and roofs. 2. Location, size and materials to be used in all screening of rooftop mechanical equipment. 3. A dashed line indicating the roof line and rooftop mechanical equipment. E. Floor plan showing dimensions and areas of all floors within proposed buildings and structures. F. Landscaping plans shall be submitted in accordance with Article III. G. Land Use Schedule. A land use schedule shall include the following: 1. Total floor area, 2. Number of dwelling units, 3. Land area, 4. Number of required and proposed parking spaces, 5. Impervious coverage, and 6. Floor area ratio (FAR). H. The following shall be submitted in support of the application for final development plan approval: 1. Deeds of dedication for all rights-of-way or easements required as a result of preliminary development plan approval, if conveyance thereof is not to be made by plat. 2. A copy of all proposed covenants and restrictions applicable to the development. 3. A copy of the property owners association bylaws as evidence of the establishment of the agency for the ownership and maintenance of any common open space and all assurances of the financial and administrative ability of such agency. 4. Evidence of satisfaction of any conditions of the preliminary development plan approval that were conditions precedent to consideration of the final development plan. 5. An application for engineering approval pursuant to the Design and Construction Manual. All applications for engineering approval shall be accompanied by the number of copies of the following as required by the City Engineer: a. Engineering drawings with the information required in the Design and Construction Manual; b. Plans, profiles and details for streets, curb and gutters, sidewalks, storm and sanitary sewers, and water lines; c. A written benchmark description and elevation; d. A storm water Master Drainage Plan that contains detailed plans for storm drainage, storm water detention, and grading plans, as specified in the Design and Construction Manual.
(Ord. No. 8779, § 1, 12-10-2019)
Ask a question about Lee's Summit law
Corpus searches the Lee's Summit sections it holds and shows the ones that match, with their citations. Free, no sign-in.
