§ 32-137 — Where protection is required
Code of Ordinances of the City of Lee's Summit, Missouri (Codified through Ordinance No. 10423, enacted July 14, 2026 (Supp. No. 56)) · Lee's Summit Code of Ordinances § 32-137
Corpus is an independent public-information project, not the official City of Lee's Summit website. Stable reference: corpuslaw.us/code/51aa0c87-5897-4b99-8c0f-f6b70f227eab
Sec. 32-137. - Where protection is required.
A. An approved backflow prevention assembly shall be installed on each service line to a consumer's water system serving premises where, in the judgment of the City, actual or potential hazards to the public potable water system exist. The type and degree of protection required shall be commensurate with the degree of hazard, as determined by the City. B. An approved air gap separation or reduced pressure principle backflow prevention assembly shall be installed at the service connection or within any premises where, in the judgment of the City, the nature and extent of activities on the premises, or the materials used in connection with the activities, or materials stored on the premises, would present an immediate and dangerous hazard to health should a cross connection occur, even though such cross connection may not exist at the time the backflow prevention device is required to be installed. This includes but is not limited to the following situations: 1. Premises having an auxiliary water supply, unless the quality of the auxiliary supply is acceptable to the City. 2. Premises having internal cross connections that are not correctable, or intricate plumbing arrangements which make it impractical to ascertain whether or not cross connections exist. 3. Premises where entry is restricted so that inspection for cross connections cannot be made with sufficient frequency or at sufficiently short notice to assure the cross connections do not exist. 4. Premises having a repeated history of cross connections being established or reestablished. 5. Premises, which due to the nature of the enterprise therein, are subject to recurring modification or expansion. 6. Premises on which any substance is handled under pressure so as to permit entry into the public water supply, or where a cross connection could reasonably be expected to occur. This shall include the handling of process waters and cooling waters. 7. Premises where materials of a toxic or hazardous nature are handled such that if backsiphonage or backpressure should occur, a serious health hazard may result. C. Facilities representing class I backflow hazards fall into one (1) or more of the categories of premises where an approved air gap separation or reduced pressure principle backflow prevention assembly is required by the City to protect the public water supply and must be installed at these facilities unless all hazardous or potentially hazardous conditions have been eliminated or corrected by other methods to the satisfaction of the City. This includes, but is not limited to the following types of facilities: 1. Aircraft and missile manufacturing plants. 2. Automotive plants including those plants which manufacture motorcycles, automobiles, trucks, recreational vehicles and construction and agricultural equipment. 3. Potable water dispensing stations which are served by a public water system. 4. Beverage bottling plants including dairies and breweries. 5. Canneries, packing houses and reduction plants. 6. Car washes. 7. Chemical, biological and radiological laboratories including those in high schools, trade schools, colleges, universities and research institutions. 8. Hospitals, clinics, medical buildings, autopsy facilities, morgues, mortuaries, and other medical facilities. 9. Metal or plastic manufacturing, fabrication, cleaning, plating or processing facilities. 10. Plants manufacturing paper and paper products. 11. Plants manufacturing, refining, compounding or processing fertilizer, film, herbicides, natural or synthetic rubber, pesticides, petroleum or petroleum products, pharmaceuticals, radiological materials or any chemical which would be a contaminant to the public water system. 12. Commercial facilities that use herbicides, pesticides, fertilizers or any chemical which would be a contaminant to the public water system. 13. Plants processing, blending or refining animal, vegetable or mineral oils. 14. Commercial laundries and dye works. 15. Sewage, stormwater and industrial waste treatment plants and pumping stations. 16. Waterfront facilities including piers, docks, marinas and shipyards. 17. Industrial facilities which recycle water. 18. Restricted or classified facilities or other facilities closed to the supplier of water or the Department. 19. Fire sprinkler systems using any chemical additives. 20. Auxiliary water systems. 21. Irrigation systems (including in-ground lawn sprinkler systems) with facilities for injection of pesticides, herbicides or other chemicals or with provisions for creating back pressure. 22. Portable tanks for transporting water taken from a public water system. 23. Facilities which have pumped or repressurized cooling or heating systems that are served by a public water system, including all boiler systems. D. Facilities representing class II backflow hazards fall into the category of premises where an approved air gap separation, reduced pressure principle backflow prevention assembly, double detector check valve assembly or double check valve assembly is required by the City to protect the public water supply and must be installed at these facilities unless all hazardous or potentially hazardous conditions have been eliminated or corrected by other methods to the satisfaction of the City. This includes, but is not limited to the following types of facilities: 1. Tanks to store water from the public water system for fire fighting only, unless such tanks meet the requirements of the Missouri Department of Natural Resources for construction to maintain bacteriological quality of the water. 2. Irrigation systems (including in-ground lawn sprinkler systems) not using chemical additives and with no provisions for creating back pressure. 3. Fire sprinkler systems not using chemical additives (double detector check valve assembly required). 4. Fire lines (double detector check valve assembly required). 5. Swimming pools with a piped or permanent connection to the water supply. 6. Cross connections that could permit introduction of contaminants into the public or customer water system and thereby create a nuisance, be aesthetically objectionable or cause minor damage to the public water system or its appurtenances.
(Code 1988, § 32-137)
Ask a question about Lee's Summit law
Corpus searches the Lee's Summit sections it holds and shows the ones that match, with their citations. Free, no sign-in.