Sec. 7-1202. - Permit and occupancy requirements.

7-1202.1 Application for permit and/or certificate: The subterranean space as well as all tenant buildings inside the subterranean space shall be classified as Group US Occupancies. The subterranean space and all interior buildings shall make application for a building permit and/or certificate of occupancy as required for surface occupancies. Approval shall be subject to compliance with all applicable sections of this article. Areas outside tenant spaces which are accessory to the use of a particular building including such areas as parking, loading docks, trash containers, public ways and streets are determined to be under the control of the owner of the subterranean space for the purposes of this Code. 7-1202.2 Subterranean master evacuation plan: A master evacuation plan is required to be submitted to the Building Official and Fire Chief for review and approval. The plan shall define public ways, streets and paths intended to provide evacuation routes to the exterior. The plan shall indicate reflectors required by section 7-1204.13 of this article. The subterranean master evacuation plan shall be updated and resubmitted for approval when public ways, streets and other evacuation routes are altered. 7-1202.3 Subterranean master ventilation plan: A master ventilation plan is required to be submitted to the Building Official and Fire Chief for review and approval. The plan shall describe the intended approach to maintain air qualities described in Section 7-1204.9.2 of this article. The plan shall show the location and size (in cfm) of all exhaust fans, ventilation fans and controls. The subterranean master ventilation plan shall be updated and resubmitted for approval when major systems are altered. 7-1202.4 Geo-technical engineering studies: Note that these studies shall only be required for the subterranean space occupancy. A registered engineer with competence in the field, and selected by the owner, shall prepare a report reviewing the structural integrity of the subterranean space. The owner shall select the engineer with approval from the Public Works Director, provided that adequate information is submitted concerning: 1. The engineer's previous experience with mine stability investigations; 2. The engineer's geological, geological engineering, geo-technical engineering, rock or mining engineering expertise; and 3. Client contact listing of similar projects. Once selected, the engineer shall submit the following information in the form of a geo-technical report to the Public Works Director for review; 7-1202.5 Surveys. 7-1202.5.1 Surface survey: The owner of the subterranean space shall provide a boundary survey of the surface of the proposed subterranean space at a scale of one inch = one hundred (100) feet (unless otherwise approved), tied to existing section corners, with USGS Sea Level datum contours at two foot intervals. 7-1202.5.2 Subterranean survey: The owner of the subterranean space shall provide a mine survey tying surface coordinate grid to subterranean space using section corners. This survey shall show locations, size, pattern and spacing of pillars, an existing and proposed portal entrances with a horizontal accuracy of plus or minus one foot. This survey shall also illustrate those areas of other mines directly adjacent (within one hundred (100) yards) to the subject tract as well as those portions of other mines being utilized for ventilation or access purposes to the subject subterranean development. Floor and ceiling spot elevations shall be made throughout the subterranean space as is necessary for drainage purposes. 7-1202.6 Geological information: The data requested below may be obtained through interpolation of the preliminary plan data if the engineer believes the information is sufficient. (Note: The following information is required to be provided for the subject tract and for those portions of adjacent mines being utilized for ventilation or access purposes.) 7-1202.6.1 Borings: A sufficient number of borings as needed for licensed registered engineer to determine geological profile and evaluate structural integrity of the roof beam. 7-1202.6.2 Profile section cuts: Vertical profile of rock and overburden from the roof of mined area to ground surface labeling and the depth of each successive geological layer. Show the elevation of the ground surface, mine floor, and roof at each profile location. These vertical profiles shall be provided with a minimum of one longitudinal and one transverse section to give a clear picture of the entire area proposed for development. The vertical profile locations shall be shown on a plan of the total area and labeled for reference. On the same map, location and reference distance to outcrop shall be shown. 7-1202.6.3 Roof beam thickness: Provide an isopach map illustrating roof beam thickness. 7-1202.6.4 Overburden thickness: Provide an isopach map illustrating overburden thickness. 7-1202.6.5 Floor material: In a short narrative format indicate floor material and composition thickness. 7-1202.7 Geo-technical evaluations: 7-1202.7.1 Structural calculations: Submittal of all necessary structural calculations including: Determination of original compressive stress loading of the rock layer prior to the mining operation; the projected loading to the support pillars; and a complete analysis of the loading patterns and support capability of the pillars, roof beam and floor of the mined area with the ultimate above ground/below ground development proposed. 7-1202.7.2 Subterranean structural inspection: An overall visual inspection of the subterranean space is required prior to development. An inspection report shall be prepared and be submitted to the Building Official. This report shall indicate major structural flaws and include a statement concerning the overall safety of the subterranean space. Prior to construction in those areas where a building is proposed, and in all common spaces, a detailed room by room inspection of the subterranean space proposed before occupancy shall be undertaken. This inspection shall indicate such items as; the surface condition of the roof beam, pillars and floor with detailed descriptions of any observed cracking, sloughing, chipping or other deterioration. Show and describe any evidence of water infiltration. 7-1202-7.3 Recommended structural modifications: Submittal of all proposed structural modifications, including any needed blasting for final room/corridor trim work or loading dock creation. 7-1202-7.4 Engineer's certification of structural adequacy: The following certification shall be provided by the owner's geo-technical engineer: I have personally observed the subterranean space described as: ___________. I have personally supervised and reviewed the computations of data and supportive information; Required on-site room by room inspections were completed. I have also completed the calculations, analysis, recommendations and conclusions as set forth in the "Geo-Technical Engineering Studies" of this Section. As a professional engineer, I hereby certify, to the best of my professional judgment, that there is no visible evidence of structural integrity problems; and/or appropriate remedial corrective measures addressing structural integrity have been completed and/or the area is suitable for occupancy subject to completion of the remedial measures as recommended in the attached survey report in the areas outlined in the attached survey for final occupancy. Name:_______ Registration No:_______ Signature:_______ Date:_______ 7-1202.8 Annual certifications and reviews: 7-1202.8.1 Smoke management: The owner of the subterranean space shall provide the City with an annual exhaust fan test showing results of air flow and clearing rates and conformance with the approved subterranean master ventilation plan. This exercise shall include operation of all fans, dampers, controls and testing of required smoke detectors in air handling systems. 7-1202.8.2 Geo-technical engineering inspections: A visual inspection of all portions of the subterranean development having final occupancy approvals shall be undertaken during the year [by] a person with competence in the field. This inspection shall indicate such items as; the surface condition of the roof beam, pillars and floor with detailed descriptions of any observed cracking, sloughing, chipping or other deterioration. Any water infiltration problems shall be described in detail. Additional inspection techniques, common to the industry shall be performed as needed. The consulting engineer shall review all inspection data, field verify potential problem areas, make recommendations, if needed and complete the following certification annually: I have personally observed the subterranean space described as: ___________. I have personally supervised and reviewed the monitoring data and supportive information. I completed on-site inspections of occupied areas where deemed necessary; and I have completed the analysis, recommendations and conclusions as set forth in the " Geo-Technical Engineering Studies" of this Section. I certify that I am currently a professional Engineer. Name:_______ Registration No:_______ Signature:_______ Date:_______ 7-1202.8.3 Air quality: A certified industrial hygienist or registered engineer shall annually certify that the air quality in the occupied areas of the subterranean development complies with the standards set forth for carbon monoxide in this article. The annual report, including required air quality readings (taken in those areas most likely to have high carbon monoxide readings) shall be submitted to the Building Official for review. The owner shall take carbon monoxide readings at a frequency of every two (2) months or more frequently as determined by the Building Official. These readings shall be recorded and available for review by the Building Official. 7-1202.8.4 Emergency evacuation drill: The owner shall conduct an annual emergency evacuation drill in conjunction with Lee's Summit Fire Department officials and modify subterranean master evacuation plan, as needed. 7-1202.8.5 Fire sprinkler maintenance: The owner shall maintain the sprinkler system in conformance with the Fire Code as amended. 7-1202.8.6 Light, ventilation and sanitation: All portions of Group US Occupancies customarily used by human beings shall be provided with artificial light, air and sanitary facilities as required in this article for the individual occupancy of the developed areas in accordance with surface building codes. Toilet facilities shall be located either in the developed occupancies or conveniently nearby in the subterranean space. 7-1202.9 Emergency response station: At intervals of approximately six hundred (600) feet along all roadways shall be an emergency response station that shall include an approved two and one-half (2.5) inch Fire Department standpipe hose connection, a complex map showing evacuation routes, and a manual pull station. The manual pull station shall be accessible to the public and shall be connected to the subterranean space fire alarm system. These stations shall be marked by a luminescent sign and be provided with emergency powered illumination providing a minimum of one foot-candle at the station. The stations will be numbered consistent with the address and column grid system in the subterranean space. 7-1202.10 Fire protection systems: Fire protection systems shall be provided as required by this article and the Building Code, as amended. Such systems shall be continuously maintained in reliable operating condition at all times, and such periodic inspections and tests shall be made as are necessary to ensure proper maintenance. When an automatic sprinkler system is out of service for more than twelve (12) hours within a 24-hour period, the building shall be evacuated. 7-1202.11 Special hazards: No hazardous occupancies as defined in the Building Code as Group H occupancies will be allowed in any subterranean space. No hazardous materials, liquids or chemicals shall be stored in Group US occupancies except as permitted in Table No. 307.1(1) of the building code for a single one-hour fire resistive control room. All tenants occupying any space and the owner of the common spaces shall be required to adhere to the City of Lee's Summit hazardous materials permit process. No liquefied petroleum gas or natural gas shall be piped, stored, utilized, or transported within any portion of an underground space. No explosives of any type or class; or fireworks of any type or class shall be manufactured, stored, utilized, or transported into any underground space. The exception to this provision are areas where active mining operations are underway and blasting permit has been issued by the City. No explosives shall be stored for mining operations except for those that are present for immediate utilization. Any magazines or other storage facilities shall be on the exterior of the underground space and shall be in accordance with an explosive storage permit issued by the Fire Department. There shall be no utilization of the common spaces outside of any building except for vehicle parking and trash dumpsters. Vehicle parking shall be limited to a maximum of seventy-two (72) hours in length for any one vehicle. Exception: Owners vehicles used exclusively for the maintenance and operation of the subterranean space may be parked for longer than seventy-two (72) hours. 7-1202.12 Emergency and exit signs: All streets and roadways within the subterranean space shall be identified for emergency purposes by readily visible signs. Lettering shall be not less than four (4) inches high and not less than a one-half-inch wide stroke and shall be of luminescent finish. The signs shall not be higher than four (4) feet above the road surface. Street names and building addresses shall be approved by the Department of Planning and Development. Each pillar on each side of a street or roadway shall be identified by name, letter or number; and below each street sign shall be a large directional arrow with the word "EXIT" in letters not less than six (6) inches high nor less than a three-quarter-inch wide stroke. All signs and letters shall be of reflective or luminescent paint. The exit arrow shall point in the direction of the nearest exit or portal. All street identification and exit routing shall be shown on color coded maps of the subterranean space, shall be available to all personnel using the subterranean space entrances and exits and shall be given to the Police and Fire Departments having jurisdiction in the subterranean space. The maps shall be brought up-to-date annually or as required to be current. All emergency evacuation routes shall be marked with roadway-mounted reflectors placed approximately twenty (20) feet apart and as approved by the Fire Department or by another evacuation route marking system as approved by the Fire Department. All common spaces and roadways shall be open at all times without security fences and/or gates provided. Portal and other perimeter exits from the subterranean space may be secured from unauthorized entry, however, any such portal or perimeter exits shall provide for emergency exiting. The undeveloped area of the subterranean space may be secured from non-authorized entry. The Fire Department shall have reasonable authority to require security by fences or other security measures to isolate specific conditions or equipment deemed hazardous by the Fire Department. 7-1202.13 Fire control room: 7-1202.13.1 Required: A Group US occupancy shall contain a fire control room immediately adjacent to an entrance portal of the subterranean space. The Fire Department shall have direct access to the fire control room via a Knox box system. The room shall contain an annunciator panel which has an electrically-operated visual signaling device for each remote alarm initiating (automatic) device, such as fire detectors, smoke detectors, water flow switches, and for each manual alarm initiating device, such as a manual pull station or manually-operated switch. 7-1202.13.2 Site plan: At or near the annunciator panel shall be a current large site plan indicating in reasonable detail the entire subterranean space, identifying by letter, name and/or number each pillar, each building, and each tenant space. The location of each manual or automatic detection device and exhaust fan shall be identified with coded letter and/or number to match the visual signal on the annunciator panel. The site plan shall be clear and concise so that the person in charge or firemen may immediately locate an emergency. 7-1202.13.3 Fire alarm: Any one of the remote manual or automatic alarm indicating devices shall activate an alarm through audible and visual notification appliances. These shall be capable of being operated from the fire control room on a building by building basis and/or as a general alarm throughout the entire subterranean space as specified for the voice communication system, as well as transmitting an alarm automatically to the local Fire Department. 7-1202.13.4 Ventilation controls: Manual controls (on-off switches) shall be provided for exhaust fans and any other fans moving air in the common spaces. 7-1202.13.5 Exhaust fans moving air to or from the surface are required to have individual on/off switches. Fans in common spaces used for general circulation may be grouped together for control by the Fire Department on one or more manual control switches. 7-1202.13.6 Radio: A radio system shall be installed in the fire control room with the specific frequencies as required by the Fire Department. This radio system shall be capable of communicating with the communication repeaters that shall be located throughout the underground space and shall be able to communicate with the Fire Department's communication center. 7-1202.13.7 Subterranean communication repeaters: The owner shall provide a constant and unobstructed communication network for the Fire Department via repeaters or other such device throughout the developed areas of the subterranean space. The system shall be designed to provide communications from the developed spaces to the fire control room. The Fire Department shall be able to communicate from the fire control room to the Fire Department's communication center. The system shall have an emergency backup power source capable of operating this system for a minimum of four (4) hours. Multiple frequencies are required if security, maintenance or other personnel use the same system. The design of the radio system is required to be approved by the Fire Department. 7-1202.14 Streets: Streets shall be provided with hard surfaces designed and maintained to support the imposed loads and shall be provided with a surface so as to provide all weather driving capabilities.

(Ord. No. 8584, § 1, 3-19-2019)

Ask a question about Lee's Summit law

Corpus searches the Lee's Summit sections it holds and shows the ones that match, with their citations. Free, no sign-in.