§ 7-1204 — Application

Code of Ordinances of the City of Lee's Summit, Missouri (Codified through Ordinance No. 10423, enacted July 14, 2026 (Supp. No. 56)) · Lee's Summit Code of Ordinances § 7-1204

Corpus is an independent public-information project, not the official City of Lee's Summit website. Stable reference: corpuslaw.us/code/14c217fc-9208-4149-8865-d2178aee0274

Sec. 7-1204. - Application.

7-1204.1 General. Group US occupancies shall be a subterranean space constructed out of a horizontal layer(s) of solid limestone and shale by an approved excavation method of mining, developed for use as manufacturing, office, warehousing and storage only. No other occupancies are permitted except for accessory uses as approved by the Building Official and the Fire Chief. Because the structure of the subterranean space is formed of solid limestone or solid limestone and shale, it shall be considered Type I construction as defined in the Building Code as amended. All exit facilities such as passageways or enclosed stairs within the common subterranean space shall be consistent with Type I construction. Each individual building within the subterranean space shall be classified and developed as Type I construction as modified herein. 7-1204.2 Fire resistance rating of structural elements. All construction on or within the subterranean space shall be of Type I construction as defined in the Building Code with the following modifications. 7-1204.2.1 Mezzanine floors: Zero-hour fire resistance including supporting columns. 7-1204.2.2 Exterior building walls: Exterior walls of buildings within subterranean spaces shall be at least two-hour fire resistive construction. 7-1204.2.3 Openings: All openings in exterior building walls shall conform to the requirements of the Building Code and shall be protected by a fire assembly having at least a one and one-half-hour fire protection rating. Exception: Glazed openings not exceeding twenty-five (25) percent of the length of the exterior wall of the tenant or building space near entrances may utilize tempered or laminated glass protected with sprinklers spaced approximately at six (6) feet apart designed to wet the entire surface of the glass on both sides. Glazing shall be held in gasketed frames to allow expansion before the sprinkler activities. Curtains or other fixtures shall not obstruct the discharge of water. 7-1204.2.4 Interior walls and permanent partitions: All interior walls and permanent partitions shall be of non-combustible materials. Except where used as backing fire retardant treated wood shall not be allowed within these assemblies. 7-1204.2.5 Tenant separations walls: Tenant separation walls shall be of at least two-hour fire resistive construction. Except where used as backing, fire retardant treated wood shall not be allowed within these assemblies. 7-1204.2.6 Openings: All openings between tenant spaces are required to be provided with one and one-half-hour automatic or self-closing doors. Exception: Non combustible penetrations for conduit and pipes if protected with approved fire stops. 7-1204.2.7 Area separation walls: Area separation walls used to subdivide spaces as required by Subsection 1304.4. of this article shall be separated by two-hour fire resistive, non-combustible walls. Openings shall be one and one-half-hour fire resistive and be limited to twenty-five (25) percent of the length of the wall. 7-1204.3 Fire resistive occupancy and use requirements. Fuel fired equipment is prohibited except as allowed by a hazardous materials permit. Buildings and tenant spaces storing hazardous materials shall be limited to a single one-hour fire resistive control area for materials listed in Table No. 307.1(1) as allowed by Section 13-44 of the Lee's Summit Code of Ordinances. 7-1204.4 Allowable floor areas—One story areas. No building of any occupancy classification shall be permitted to have unlimited area. The maximum net usable area for each building including mezzanines shall be limited to three hundred sixty thousand (360,000) square feet of gross area. Combinations of spaces which are greater than three hundred sixty thousand (360,000) gross square feet due to area separation walls shall be provided with exterior access and standpipes as required by the Fire Chief. 7-1204.5 Interior building exiting. Except as specifically modified herein, every building or portion thereof shall be provided with exits as required by the requirements of Chapter 10 of the Building Code. 7-1204.5.1 Exit through adjoining areas: Exits from a room may open into a single adjoining room or area if such adjoining room or area provides a direct means of egress to an exit corridor, exit stairway, public way, street, horizontal exit or exit passageway. Foyers, lobbies and reception rooms shall not be construed as adjoining rooms when provided obvious and unobstructed means to an exit. 7-1204.5.2 Definition of exit: Occupants reaching a street or public way may be considered exited from tenant building spaces when they reach a common space and adequate evacuation facilities from the subterranean space are provided in accordance with Subsection 7-1204.6 of this article. 7-1204.6 Subterranean evacuation facilities. 7-1204.6.1 Evacuation facilities: Common spaces including streets and roadways throughout the subterranean space shall be considered to be horizontal, continuous and unobstructed means of egress to an exterior door, portal, horizontal exit, enclosed exit passageway or enclosed stair. Any street less than twenty (20) feet in width shall be designated for one-way traffic only. 7-1204.6.2 Occupant load determination: The occupant load used to determine the required exit capacity from the subterranean space shall be not less than one-fifth of the total occupant load of all interior building spaces considered simultaneously occupied. 7-1204.6.3 Number of evacuation routes: Every subterranean space shall have not less than two (2) vehicle entrances or portals. Every subterranean space having an occupant load of five hundred (500) to nine-hundred-ninety-nine (999) shall have not less than three separate evacuation routes. Every subterranean space having an occupant load of over one thousand (1,000) persons shall have not less than four separate evacuation routes. 7-1204.6.4 Width of evacuation routes: The total width of evacuation routes in feet shall not be less than the total occupant load divided by sixty (60) people per foot. Such width shall be divided approximately equally among the separate evacuation routes or portals provided. 7-1204.6.5 Arrangement of evacuation routes: Evacuation routes shall be arranged a reasonable distance apart so that if one becomes blocked, the other route or routes will be available. The minimum distance between the vehicle portals shall be a minimum of one-fourth of the maximum diagonal of the subterranean space but need not exceed three hundred (300) feet measured along the subterranean interior perimeter. 7-1204.6.6 Travel distance: The maximum distance from the discharge point of a tenant space or building to an exterior door, portal, horizontal exit, enclosed exit passageway or enclosed stair shall be limited to two thousand six hundred forty (2,640) feet. 7-1204.6.7 Entrance prohibition: Upon the sounding of a general fire alarm, red flashing lights shall activate at each portal. These lights shall be located adjacent to a sign which indicates "Do not enter when light flashing, Fire in the subterranean space." The sign shall be subject to the approval of the Fire Department. 7-1204.7 Fire protection systems. 7-1204.7.1 General: Fire protection systems shall be provided as set forth in Chapter 9 of the Building Code except when modified in this article. 7-1204.7.2 Sprinkler system required: All occupied areas of the subterranean space including all streets, public ways, parking lots, loading docks, and any other developed areas, shall be protected by an automatic fire sprinkler system. 7-1204.7.3 Wet standpipes: A two and one-half (2.5) inch wet standpipe connection shall be installed inside the building at each exterior door of every building and at any door of any interior exit corridor. A two and one-half (2.5) inch wet standpipe hose connection shall also be provided at each emergency response station. In addition, a two and one-half (2.5) inch wet standpipe hose station shall be installed in all roadway areas at distances of approximately three hundred (300) feet apart, including those that are installed at the emergency response stations. All standpipe piping and valving shall be painted day-glo yellow as approved by the Fire Department. 7-1204.7.4 Standby power: Standby power shall be provided for emergency exit illumination, fire alarm, fire pump, and lighting and controls in the fire control room. 7-1204.7.5 Emergency response vehicle: The owner shall provide a one-time payment for an emergency response vehicle that will be owned and operated by the Fire Department. The emergency response vehicle shall be a heavy-duty, electric-powered vehicle that will operate for a minimum of two (2) hours continuous operation. It shall include the following minimum equipment. On-board 4,500 psi air system with a supply of sixty (60) minutes for four (4) fire fighters with four fixed air supply ports. Eight (8) one-hour four thousand five hundred (4,500) psi SCBA OSHA approved bottles. Six hundred (600) feet of one and three-quarter-inch fire hose. Two (2) one and three-quarter-inch fire nozzles and two (2) two and one-half (2.5) inch reducers. Sixteen (16) channel UHF, five (5) watt mobile radio with multiple frequencies. Twenty thousand (20,000) cfm positive pressure ventilation fan. Two (2) minimum low mounted fog lights. The owner shall provide a secure parking location near the fire control room with electrical power for recharging the cart. 7-1204.7.6 Fire hydrants. 7-1204.7.6.1 Where required: A minimum of one fire hydrant shall be located at each outside parking lot and each portal unless otherwise approved by the Fire Chief. Fire hydrants near portals may be fed from the subterranean space standpipe water supply system. 7-1204.7.6.2 Hydrant requirements: All fire hydrants installed on the exterior of the subterranean space shall be in accordance with the Design and Construction Manual of the City of Lee's Summit. 7-1204.8 Building mechanical systems. 7-1204.8.1 General: When heating, cooling or ventilation systems are provided in buildings and tenant spaces of Group US Occupancies, such systems shall be installed in accordance with the mechanical code. 7-1204.8.2 Air quality: The quality of air in Group US Occupancies shall be certified annually as established in Section 7-1202 of this article. Ventilation within buildings and tenant spaces shall be designed to limit the concentration of harmful gases gauged by carbon monoxide levels as follows: Thirty-five (35) ppm over a one-hour period. Nine (9) ppm over an eight-hour period. 7-1204.9 Subterranean space ventilation. 7-1204.9.1 General: The quality of air in Group US Occupancies shall be certified annually as established in this article. 7-1204.9.2 Air quality: Ventilation within the subterranean space to be designed to limit the concentration of harmful gases gauged by carbon monoxide levels. Carbon monoxide levels to be limited to an average fifty (50) ppm in streets or public ways over any one-hour period. Carbon monoxide levels exceeding this amount shall be rectified. 7-1204.10 Plumbing systems. Plumbing systems installed in Group US Occupancies, including developed areas therein, shall comply with the applicable requirements of the Building Code and the Plumbing Code, except as modified by this article. 7-1204.10.1 Vent termination: Each vent pipe or stack serving a plumbing system in a building in a subterranean space shall terminate vertically through the roof or horizontally through the wall of such building to a street or yard. When terminated through a well, the vent terminal shall be as high above the floor as possible and shall be at least twenty-five (25) feet from any door, window or ventilation intake opening in the building wall. The open end of such vent terminal shall be covered with a protective screen. 7-1204.10.2 Subterranean sewer structure trap: Whenever a building sewer serving a subterranean space conveys sanitary sewage to a public sewer, a trap shall be installed on the main sewer line outside the subterranean space. The purpose of the trap is to prevent odors or gases and/or pests from entering the subterranean space plumbing system from the public sewer. It is not to be used as a ventilating duct for the public sewer. A fresh-air inlet shall be connected on the upstream side of this trap so as not to interfere with the cleanouts therein. The upper end of the fresh-air inlet shall terminate in a protected area at least twenty (20) feet from a portal or other opening into the subterranean space. The upper end of the inlet shall be turned down and shall be provided with a substantial protected, screened cover. The air inlet shall be sized properly and shall remain open in order to maintain fixture trap seals in the plumbing system. 7-1204.11 Electrical systems. Electrical systems installed in Group US occupancies, including developed areas therein, shall comply with the applicable requirements of the Building Code and the Electrical Code, except as modified by this article. 7-1204.12 Undeveloped areas. Undeveloped areas in Group US occupancies which are not protected by an automatic fire extinguishing system shall not be used for any purpose, including vehicle parking, truck or trailer parking, or material storage. The owner shall be responsible for providing and maintaining an effective system that shall prevent the unauthorized use of non-sprinklered undeveloped areas. Exception: Non-sprinklered undeveloped spaces may be used for mining operations and storage of loose rock and sand. 7-1204.13 Reflectors. A system of roadway-mounted reflectors shall be utilized for exiting and to indicate the location of Fire Department hose connection locations. Green reflectors shall show a path indicating the direction of travel to the closest roadway exit or portal. Yellow reflectors shall indicate the direction for a secondary egress point, whether from an exit or portal. A red reflector shall indicate the travel direction toward a dead end where no egress can be accomplished from the underground space. The reflectors shall be placed in accordance with the approval of the Fire Department but shall be placed approximately twenty (20) feet apart, unless another exiting system is proposed by the owner and approved by the Fire Department. 7-1204.14 Penalty. It shall be unlawful for any person to violate any section of this Code, or to fail to comply with mandatory requirements of this Code. The violation of any such provision or provisions shall be punishable as set out in Section 1-13.A. of the City Code of Ordinances.

(Ord. No. 8584, § 1, 3-19-2019)

Ask a question about Lee's Summit law

Corpus searches the Lee's Summit sections it holds and shows the ones that match, with their citations. Free, no sign-in.