For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8.050 — General provisions

Code of Ordinances of the City of Lee's Summit, Missouri (Codified through Ordinance No. 10423, enacted July 14, 2026 (Supp. No. 56)) · Lee's Summit Unified Development Ordinance § 8.050

Corpus is an independent public-information project, not the official City of Lee's Summit website. Stable reference: corpuslaw.us/code/827f9195-0744-419b-b616-025d673e3ba2

Sec. 8.050. - General provisions.

A. Building types. 1. Single-family residential: Detached single-family homes, accessory dwellings, bed and breakfast homestay, and group homes approved within a single-family or two-family home. 2. Two-family residential: Two-family homes (duplex) 3. Attached residential: Triplex, quadplex, townhome, and rowhouse. 4. Multi-family residential: Apartments, bed and breakfast inn, nursing homes, hospice homes, treatment centers, homeless shelters, retirement villages, independent living or assisted living apartment communities, and other similar high density residential developments. 5. Non-residential buildings in a residential zoning district: Schools, churches, places of assembly, community centers, community food and personal support services, cultural facilities, funeral homes and mortuaries, libraries, public facilities, and government buildings. 6. Commercial/retail buildings: Single and multi-tenant commercial buildings, day care centers, restaurants, financial institutions, hotels, motels, mini/self-storage buildings, auto service businesses in commercial zoning districts, and recreational and entertainment buildings. 7. Office and civic buildings: Single and multi-tenant office buildings including medical offices, clinics, and hospitals. When located in non-residential zoning districts: schools, universities, churches, places of assembly, community centers, cultural facilities, funeral homes and mortuaries, libraries, public facilities, and government buildings. 8. Mixed-use buildings: Multi-story buildings that contain two or more different uses such as residential and retail/office uses. 9. Downtown buildings: Buildings or structures located within the Downtown Core Area as shown in Subdivision 8. 10. Industrial buildings: A building or structure constructed for warehouse, distribution, flex industrial, and other industrial uses and located within the Planned Commercial Services (CS), Planned Industrial (PI), or Planned Mixed Use (PMIX) zoning districts. 11. Buildings within the specified metal building locations: Buildings or structures located within the boundaries of the Specified Metal Building Locations as shown on the map in Section 8.080.C. B. The following standards apply to all sites excluding single-family dwellings, two-family dwellings, and townhouse/row dwellings. 1. Four-sided architectural design. Buildings shall incorporate four sided architecture. Architectural elements (horizontal or vertical) shall extend around the building and utilize the same, compatible, or complementary materials on all building facades. 2. Top, middle, and base design. Buildings shall clearly express a top, a middle, and a base. Transitions from between the top, middle, and base shall be accomplished by a change in wall plane, roof overhang, and/or a change in building materials or color. The Approving Authority may waive this requirement based upon the building's architectural style, use, or other factors deemed relevant. [image omitted; see the official code] 3. Wall and roof articulation. Buildings shall have regular variations and changes (articulations) in the wall planes, roof lines, and roof slopes. The minimum wall and roof articulation requirements are provided in Sections 8.070 and 8.080 herein this subdivision. a. Examples of wall articulation methods include, but are not limited to: i. Projections or recesses in the wall plane of at least two feet in depth. ii. Use of columns, piers, pilasters, or other equivalent structural and/or decorative elements that project at least two feet beyond the wall plane in a manner that complements the overall aesthetic appearance of the building. b. Examples of roof articulation methods include, but are not limited to: i. A change in direction of the roof pitch or slope. ii. The raising or lowering of the parapet wall, if applicable. iii. The use of a tower element or other similar building feature. 4. Application of exterior building materials on primary facades. This subsection contains information on the appropriate application when the following building materials are used: a. Multiple façade materials. The use of multiple façade materials is required and the transitions from one wall material to another shall follow a level horizontal or vertical line. b. Application of brick and stone masonry. Heavy exterior materials, such as any type of brick or stone masonry, shall be applied as traditionally used as a building foundation and structural material. Brick or stone masonry that appears to be unsupported or 'float' within a façade shall not be permitted, e.g., stone applied to a roof dormer or stone placed directly above doors/windows without a supporting lintel above the door/window. c. Painting of brick and stone masonry. Brick and stone masonry exterior finishes shall not be painted, unless approved by the Approving Authority based on the building design, architectural style, or current condition of the brick or stone. d. Exterior insulation and finish systems (EIFS). Subject to the provisions of Sections 8.070 and 8.080 herein, the use of Exterior Insulation and Finish System (EIFS) on a building façade is permitted above the first ten feet of the building finished floor elevation for a single-story building and is permitted on those floors above the first-floor elevation for a multi-story building. e. Thin brick and stone masonry veneer. Thin brick or stone masonry veneer, including brick and stone paneling, shall comply with the following: i. Thin brick and stone masonry veneer or paneling shall only be used in applications where the apparent thickness of the bricks or stones will not be distinguished or is otherwise addressed by adjustments in the wall plane to simulate the appearance of full depth brick or stone. ii. 'L' shaped brick/stone corner pieces and full-depth brick/stone caps shall be utilized at all corners and edges to maintain the appearance of full-depth brick/stone. iii. Thin brick and stone masonry veneer or paneling shall be continued (returned) a minimum of 12 inches around all wall corners to further maintain the appearance of full-depth brick or real stone and shall be terminated at a ninety-degree angle inside corner along the given facade. f. Use of trim on primary façades. Appropriately scaled trim shall be included around all window and door openings, building corners, roof lines, and façade material transitions located on primary façades, unless the use of trim is considered inappropriate based on the building's architectural style. g. Building façadism discouraged. Building façadism is discouraged. Windows or dormers should be in proportion with and match the adjoining roof pitch and have the appearance of being functional and operational. Hip or mansard roofs that only partially conceal a roof well or low slope roof area are also discouraged. h. Franchise architecture discouraged. The use of franchise or trade-marked building shapes or integral building forms that are readily identifiable with a specific commercial franchise is discouraged. Buildings are encouraged to be designed to appear as their intended use, e.g., a restaurant building can look like a building for a restaurant; however, with the signage removed, the building should not be recognizable as belonging to a specific commercial business or franchise. i. Application of windows and doors on commercial storefronts. All commercial and retail building façades that face a public or private street shall conform with the following standards: i. Fenestrations with clear glass shall occupy no less than 50 percent of the pedestrian view zone. ii. All doors, including any overhead doors, located within the pedestrian view zone shall contain no less than 75 percent clear glass. j. Overhead doors. Street facing overhead doors (garage doors) are discouraged. i. Any street facing overhead door not regulated by subsection i above shall have no less than 50 percent clear glass and shall be recessed a minimum of 18 inches into the building wall plane; or ii. Shall include additional architectural enhancements or building materials to mitigate the visual impact from the right-of-way. Additional site design enhancements including fencing, landscaping, and increased setbacks may also be required. k. Awnings and canopies. Awnings and canopies are encouraged but must be functional, provide shade and shelter to the building entry, be designed in scale and proportion to the mass of the building, and constructed of high-quality and durable building materials.

(Ord. No. 10182, § 4(Exh. D), 8-12-2025)

Ask a question about Lee's Summit law

Corpus searches the Lee's Summit sections it holds and shows the ones that match, with their citations. Free, no sign-in.