For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 8.080 — Non-residential building types and standards

Code of Ordinances of the City of Lee's Summit, Missouri (Codified through Ordinance No. 10423, enacted July 14, 2026 (Supp. No. 56)) · Lee's Summit Unified Development Ordinance § 8.080

Corpus is an independent public-information project, not the official City of Lee's Summit website. Stable reference: corpuslaw.us/code/7cf7ea23-88d0-414d-9c3f-0bdcd2f84c49

Sec. 8.080. - Non-residential building types and standards.

A. Non-residential building types. 1. Non-residential buildings in a residential zoning district; 2. Commercial/retail buildings; 3. Office and civic buildings; 4. Mixed-use buildings; 5. Downtown buildings; 6. Industrial buildings; 7. Buildings within the specified metal building locations. B. Table 8.I-3. Standards by Non-Residential Building Type. Standards by Non-Residential Building Type Building Type | Major Façade Materials | Wall Articulation | Entryways | Roofing | Roof Articulation Non-Residential Buildings in a Residential Zoning District | Each primary façade shall have no less than 3 different Class 1 or 2 building materials together comprising at least 1/2 of the façade area. | The Primary façade shall have a wall articulation (as provided herein Sec. 8.050) no less than once every 60 linear feet. | All main building entries must be covered, either through a projection or a recession in the wall plane. | Class 1, 2, or 3 roofing materials. | The roofline shall have an articulation no less than once every 100 linear feet. Each secondary façade shall have no less than 3 different Class 1, 2, or 3 building materials. Class 4 façade materials shall not be permitted on any primary or secondary façade. Commercial/Retail Buildings | Each primary façade shall have no less than 3 different Class 1 or 2 building materials together comprising at least 1/2 of the façade area. | Buildings shall be no less than 18 feet in height. | All main building entries must be covered, either through a projection or a recession in the wall plane. | Class 1, 2, or 3 roofing materials. | The roofline shall have an articulation no less than once every 100 linear feet. Each secondary façade shall have no less than 3 different Class 1, 2, or 3 building materials. | The Primary façade shall have a wall articulation (as provided herein Sec. 8.050) no less than once every 60 linear feet. Class 4 façade materials shall not be permitted on any primary or secondary façade. Office and Civic Buildings | Each primary façade shall have no less than 3 different Class 1 or 2 building materials together comprising at least 1/2 of the façade area. | Building shall be no less than 18 feet in height. | All main building entries must be covered, either through a projection or a recession in the wall plane. | Class 1, 2, or 3 roofing materials. | The roofline shall have an articulation no less than once every 100 linear feet. Each secondary façade shall have no less than 3 different Class 1, 2, or 3 building materials. | The Primary façade shall have a wall articulation (as provided herein Sec. 8.050) no less than once every 80 linear feet. Class 4 façade materials shall not be permitted on any primary or secondary façade. Mixed-Use Buildings | Each primary façade shall have no less than 3 different Class 1 or 2 building materials together comprising at least 1/2 of the façade area. | Building shall be no less than 24 feet in height. | All main building entries must be covered, either through a projection or a recession in the wall plane. | Class 1, 2, or 3 roofing materials. | The roofline shall have an articulation no less than once every 100 linear feet. Each secondary façade shall have no less than 3 different Class 1, 2, or 3 building materials. | The Primary façade shall have a wall articulation (as provided herein Sec. 8.050) no less than once every 60 linear feet. Class 4 façade materials shall not be permitted on any primary or secondary façade. Downtown Buildings | Please refer to Subdivision 8. Industrial Buildings | Each primary façade shall have no less than 3 different Class 1 and 2 building materials together comprising at least 1/4 of the façade area. | The Primary façade shall have a wall articulation (as provided herein Sec. 8.050) no less than once every 150 linear feet. | n/a | n/a | n/a Class 4 façade materials shall not be permitted on any primary or secondary façade area. Buildings located within the Specified Metal Building Locations (refer to map) | Metal buildings are permitted. Each primary façade shall have no less than 3 different Class 1, 2, 3, or 4 building materials. The base of all sides of the building shall utilize materials from Class 1, 2, or 3 only or include a protective feature such as bollards, planting beds, or other items placed along the building base. | n/a | All main building entries must be articulated. | n/a | n/a C. Map of specified metal building locations. [image omitted; see the official code]

(Ord. No. 10182, § 4(Exh. D), 8-12-2025)

Ask a question about Lee's Summit law

Corpus searches the Lee's Summit sections it holds and shows the ones that match, with their citations. Free, no sign-in.