For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 11.79.100 — Swimmer loading

Revised Code of the City of Saint Louis, 2020, Annotated (Supp. No. 11: codified through Ordinance No. 72042, enacted October 30, 2025) · St. Louis Revised Code § 11.79.100

Corpus is an independent public-information project, not the official City of St. Louis website. Stable reference: corpuslaw.us/code/e745f406-b9dc-4416-8521-73781316a4d6

11.79.100 - Swimmer loading.

Designation of Area. For the purposes of computing swimmer capacity for design, those portions of the pool four feet or less in depth shall be designated "non-swimmer" areas. Portions of the pool over four feet in depth shall be designated as the swimming area. Pool areas shall be determined as follows: A. Ten (10) square feet of pool surface shall be provided for each non-swimmer expected in the water at time of maximum load. B. Twenty-four (24) square feet of pool area shall be provided for each swimmer expected in the water. C. Three hundred (300) square feet of pool area shall be reserved around each diving board or diving platform and this area shall not be included in computing the area of the swimming section. Twenty (20) persons is the maximum number allowed for the area within a ten (10) foot radius of each diving board or platform.

(1994 C., § 11.79.100; Ord. No. 65567, § 10, 2002.)

Ask a question about St. Louis law

Corpus searches the St. Louis sections it holds and shows the ones that match, with their citations. Free, no sign-in.