For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 3.5 — Residential districts

Zoning Ordinance, City of Brandon, adopted April 6, 2026 · Brandon Zoning Regulations § 3.5

Corpus is an independent public-information project, not the official City of Brandon website. Stable reference: corpuslaw.us/code/8dab5c41-9882-45fb-b238-5ff3ba431d6d

3.5 Residential districts.

![Official zoning figure, printed page 16 (PDF page 17)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/d34621d131b01bd0d6ce0de9eec97f2b5c6af8a9743b6d93f0702da7e433757d-zoning-figure-17-2.png)

3.5.1 RE-43 Residential Estate, Large Lot (RE-43)

PURPOSE

TYPICAL BUILDING TYPE

The purpose of the Residential Estate, Large Lot District is to protect certain areas of rural development character within the city so they may continue

to be used for rural neighborhood purposes including residential, recreational and agricultural purposes. It is the intent of this ordinance that these districts be located only in the more undeveloped areas of the City of Brandon. These areas may contain limited or rural-level infrastructure. Nothing in this section shall be interpreted as creating an obligation upon the City to extend public utilities or roadways beyond existing service limits.

| PRINCIPAL INTENSITY AND DIMENSIONAL STANDARDS | PRINCIPAL INTENSITY AND DIMENSIONAL STANDARDS | |-------------------------------------------------|-------------------------------------------------| | Minimum lot area (sf) | 43,560 | | Minimum lot width (ft) | 100 | | Minimum floor area per dwelling unit (sf) | 2,200 | | Maximum building coverage (% of lot area) | n/a | | Maximum height (ft) | 40 | | Minimum front yard depth (ft) | 50 | | Minimum side yard depth (ft) | 10 | | Minimum rear yard depth (ft) | 30 | | District land use | See section 4 | | Development standards | See section 5 | | Mobility standards | See section 6 | | Parking requirements | See section 7 |

![Official zoning table, printed page 16 (PDF page 17)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/2853efa4663d08a9fbe6adb29c9810b7dd357df54578e6d14e0eda664edb0c84-zoning-table-17-5.png)

PRINCIPAL INTENSITY AND DIMENSIONAL STANDARDS

TYPICAL LOT PATTERN

Minimum lot area (sf)

43,560

Minimum lot width (ft)

100

Minimum floor area per dwelling unit (sf)

2,200

Maximum building coverage (% of lot area)

n/a

Maximum height (ft)

40

Minimum front yard depth (ft)

50

Minimum side yard depth (ft)

10

Minimum rear yard depth (ft)

30

District land use

See section 4

Development standards

See section 5

Mobility standards

See section 6

Parking requirements

See section 7

NOTES: (sf = square feet, ft = feet)

Height limits shall not apply to appurtenances and not intended for human occupancy or to be used for any commercial or advertising purposes.

TYPICAL DEVELOPMENT CONFIGURATION

![Official zoning figure, printed page 17 (PDF page 18)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/4eec62a11f895ee51e2cacd5a33b1a4c522a9326c6ded34e6ad7739cd98caeee-zoning-figure-18-3.png)

3.5.2 RE-32 Residential Estate, Moderate Lot (RE-32)

PURPOSE

TYPICAL BUILDING TYPE

The purpose of the Residential Estate District is to protect certain areas of rural-like development character within the city so they may continue to be used for neighborhood purposes including residential, recreational and agricultural purposes. It is the intent of this ordinance that these districts be located in the more undeveloped areas of the City of Brandon, which may have restricted or limited infrastructure including transportation at the time of adoption. These areas may contain limited or rural-level infrastructure. Nothing in this section shall be interpreted as creating an obligation upon the City to extend public utilities or roadways beyond existing service limits.

PRINCIPAL INTENSITY AND DIMENSIONAL STANDARDS

TYPICAL LOT PATTERN

| Minimum lot area (sf) | 32,670 | |-------------------------------------------|---------------| | Minimum lot width (ft) | 90 | | Minimum floor area per dwelling unit (sf) | 2,200 | | Maximum building coverage (% of lot area) | n/a | | Maximum height (ft) | 40 | | Minimum front yard depth (ft) | 50 | | Minimum side yard depth (ft) | 8 | | Minimum rear yard depth (ft) | 30 | | District land use | See section 4 | | Development standards | See section 5 | | Mobility standards | See section 6 | | Parking requirements | See section 7 |

![Official zoning table, printed page 17 (PDF page 18)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/dbd33d2e5a2e83e508f8c1558a65d90a4c97ffa066efad937d4821e8bb96ff7b-zoning-table-18-6.png)

32,670

Minimum lot area (sf)

90

Minimum lot width (ft)

2,200

Minimum floor area per dwelling unit (sf)

Maximum building coverage (% of lot area) n/a

40

Maximum height (ft)

50

Minimum front yard depth (ft)

8

Minimum side yard depth (ft)

30

Minimum rear yard depth (ft)

See section 4

District land use

See section 5

Development standards

See section 6

Mobility standards

See section 7

Parking requirements

NOTES: (sf = square feet, ft = feet)

Height limits shall not apply to appurtenances and not intended for human occupancy or to be used for any commercial or advertising purposes.

TYPICAL DEVELOPMENT CONFIGURATION

3.5.3 RE-21 Residential Estate, Neighborhood Lot (RE-21)

PURPOSE

TYPICAL BUILDING TYPE

![Official zoning figure, printed page 18 (PDF page 19)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/3de18065b29aaab0f8d4b96f09052fd1fc72b84f26a504c89edb5a53403cb7b5-zoning-figure-19-4.png)

The purpose of the Residential Estate, Neighborhood Lot District is to allow for estate style lots within the city so they may be used for residential platted or unplatted development purposes. It is the intent of this ordinance that these districts serve as a transition from more dense residential development and areas which are less dense or undeveloped. These areas may contain limited or rural-level infrastructure. Nothing in this section shall be interpreted as creating an obligation upon the City to

extend public utilities or roadways beyond existing service limits.

PRINCIPAL INTENSITY AND DIMENSIONAL STANDARDS

TYPICAL LOT PATTERN

| Minimum lot area (sf) | 21,780 | |-------------------------------------------|---------------| | Minimum lot width (ft) | 90 | | Minimum floor area per dwelling unit (sf) | 2,200 | | Maximum building coverage (% of lot area) | n/a | | Maximum height (ft) | 40 | | Minimum front yard depth (ft) | 50 | | Minimum side yard depth (ft) | 8 | | Minimum rear yard depth (ft) | 30 | | District land use | See section 4 | | Development standards | See section 5 | | Mobility standards | See section 6 | | Parking requirements | See section 7 |

![Official zoning table, printed page 18 (PDF page 19)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/565b91b750da501e17ec9cc8731f93ab639870e1ac18d4e6de0e1ca552a89785-zoning-table-19-7.png)

![Official zoning figure, printed page 18 (PDF page 19)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/6965afa00d15341b62000a662c969e8b83d015c9a9da4da985c4edeec714d50d-zoning-figure-19-6.png)

NOTES: (sf = square feet, ft = feet)

Height limits shall not apply to appurtenances and not intended for human occupancy or to be used for any commercial or advertising purposes.

TYPICAL DEVELOPMENT CONFIGURATION

![Official zoning figure, printed page 18 (PDF page 19)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/5d9b5d66a7b7bb303ef0a44b0baef594f08f12f83fc18572cfe5dc36f503d7cc-zoning-figure-19-5.png)

3.5.4 R-12 SUBURBAN NEIGHBORHOOD (R-12)

PURPOSE

TYPICAL BUILDING TYPE

![Official zoning figure, printed page 19 (PDF page 20)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/e9fe862d7f1eedb591e5d05fa98d369c37fdad5425fe5eef9276255ff1f9554e-zoning-figure-20-7.png)

The purpose of the R-12 Suburban Neighborhood District is to provide areas for the development of low to moderate density, single-family residential and related uses. It is the intent of this ordinance that existing residential developments be protected from encroachment of undesirable and incompatible uses and that new developments be constructed according to sound, reasonable, and desirable regulations as stated within this ordinance.

PRINCIPAL INTENSITY AND DIMENSIONAL STANDARDS

TYPICAL LOT PATTERN

| Minimum lot area (sf) | 12,000 | |-------------------------------------------|---------------| | Minimum lot width (ft) | 90 | | Minimum floor area per dwelling unit (sf) | 2,000 | | Maximum building coverage (% of lot area) | 30 | | Maximum height (ft) | 40 | | Minimum front yard depth (ft) | 30 | | Minimum side yard depth (ft) | 8 | | Minimum rear yard depth (ft) | 25 | | District land use | See section 4 | | Development standards | See section 5 | | Mobility standards | See section 6 | | Parking requirements | See section 7 |

![Official zoning table, printed page 19 (PDF page 20)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/c2fcb19291f965e01b5aabf490ce4c78992f781004c246738bada615ca5a811a-zoning-table-20-8.png)

![Official zoning figure, printed page 19 (PDF page 20)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/6b3354f97620dc9dd2ac127e97c1be86a74e513a3415a17e026e025a12701cff-zoning-figure-20-9.png)

NOTES: (sf = square feet, ft = feet)

Height limits shall not apply to spires, cupolas, antennas, chimneys, or other mechanical appurtenances usually required to be placed above the roof level and not intended for human occupancy or to be used for any commercial or advertising purposes.

TYPICAL DEVELOPMENT CONFIGURATION

![Official zoning figure, printed page 19 (PDF page 20)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/4dd09297128a3ba5f54ef024b6094f8ff42a646a8b6fdb4c900322792bf4a63f-zoning-figure-20-8.png)

![Official zoning figure, printed page 20 (PDF page 21)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/99012f45b14ca2f52e553237721fdcbada1404523cd9a6446fe038683ef17a94-zoning-figure-21-10.png)

3.5.5 R-8 SUBURBAN MEDIUM DENSITY NEIGHBORHOOD (R-8)

PURPOSE

TYPICAL BUILDING TYPE

The purpose of the R-8 Medium Density Neighborhood District is to provide areas for the development of medium density, single-family residential and related uses. It is the intent of this ordinance that existing residential developments be protected from encroachment of undesirable and incompatible uses and that new developments be constructed according to sound, reasonable, and desirable regulations as stated within this ordinance.

PRINCIPAL INTENSITY AND DIMENSIONAL STANDARDS

TYPICAL LOT PATTERN

| Minimum lot area (sf) | 8,000 | |-------------------------------------------|---------------| | Minimum lot width (ft) | 85 | | Minimum floor area per dwelling unit (sf) | 1,800 | | Maximum building coverage (% of lot area) | 45% | | Maximum height (ft) | 40 | | Minimum front yard depth (ft) | 25 | | Minimum side yard depth (ft) | 5 | | Minimum rear yard depth (ft) | 25 | | District land use | See section 4 | | Development standards | See section 5 | | Mobility standards | See section 6 | | Parking requirements | See section 7 |

![Official zoning table, printed page 20 (PDF page 21)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/81febf37eb6bd5d024713bd92cf602917d0c9e00087144dd5eda4fc98c55ba4b-zoning-table-21-9.png)

Minimum lot area (sf)

8,000

Minimum lot width (ft)

85

Minimum floor area per dwelling unit (sf)

1,800

Maximum building coverage (% of lot area)

45%

Maximum height (ft)

40

Minimum front yard depth (ft)

25

Minimum side yard depth (ft)

5

Minimum rear yard depth (ft)

25

District land use

See section 4

Development standards

See section 5

Mobility standards

See section 6

Parking requirements

See section 7

NOTES: (sf = square feet, ft = feet)

Site plan review is required according to section 9.11.

Height limits shall not apply to spires, cupolas, antennas, chimneys, or other mechanical appurtenances usually required to be placed above the roof level and not intended for human occupancy or to be used for any commercial or advertising purposes.

TYPICAL DEVELOPMENT CONFIGURATION

![Official zoning figure, printed page 21 (PDF page 22)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/c5b8f0cba5253808b20417426bb6f111342b34dca4efe1297cc2218a08214173-zoning-figure-22-11.png)

3.5.6 RM-8 SUBURBAN MIXED NEIGHBORHOOD (RM-8)

PURPOSE

TYPICAL BUILDING TYPE

The purpose of the RM-8 Mixed Neighborhood District is to provide areas for the development of moderate density, single-family residential uses in moderately spacious surroundings. It is the intent of this ordinance that these districts be located in suburban and intermediate portions of the city as well as in established moderate density residential areas. It is further the intent of this ordinance that new and existing developments in this district be protected from encroachment of higher density residential uses.

PRINCIPAL INTENSITY AND DIMENSIONAL STANDARDS

TYPICAL LOT PATTERN

| Minimum lot area (sf) | 8,000 | |-------------------------------------------|---------------| | Minimum lot width (ft) | 85 | | Minimum floor area per dwelling unit (sf) | 1,800 | | Maximum building coverage (% of lot area) | 45% | | Maximum height (ft) | 40 | | Minimum front yard depth (ft) | 25 | | Minimum side yard depth (ft) | 5 | | Minimum rear yard depth (ft) | 20 | | District land use | See section 4 | | Development standards | See section 5 | | Mobility standards | See section 6 | | Parking requirements | See section 7 |

![Official zoning table, printed page 21 (PDF page 22)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/f23b92fc2aebced552d11417f4df770a16858b629b65452bc7fb05afadd897a7-zoning-table-22-10.png)

Minimum lot area (sf)

8,000

Minimum lot width (ft)

85

Minimum floor area per dwelling unit (sf)

1,800

Maximum building coverage (% of lot area)

45%

Maximum height (ft)

40

Minimum front yard depth (ft)

25

Minimum side yard depth (ft)

5

Minimum rear yard depth (ft)

20

District land use

See section 4

Development standards

See section 5

Mobility standards

See section 6

Parking requirements

See section 7

NOTES: (sf = square feet, ft = feet)

Site plan review is required according to section 9.11.

Height limits shall not apply to spires, cupolas, antennas, chimneys, or other mechanical appurtenances usually required to be placed above the roof level and not intended for human occupancy or to be used for any commercial or advertising purposes.

TYPICAL DEVELOPMENT CONFIGURATION

3.5.7 RM-4 TOWNHOUSE AND ZERO LOT LINE RESIDENTIAL (RM-4)

PURPOSE

TYPICAL BUILDING TYPE

![Official zoning figure, printed page 22 (PDF page 23)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/3a99e7f5dc38ceda2e414142c92800113e3451a89247c2ab556d58f00b69e699-zoning-figure-23-12.png)

The purpose of the RM-4 Town House and Zero Lot Line Residential District is to provide areas for the development of moderate to high density residential uses and structures in moderately spacious surroundings. These districts are intended to be located in intermediate portions of the city where a protected environment suitable for moderate density residential use can be provided. However, the use of this district is appropriate on a smaller scale as a transitional area between low-density residential districts and commercial districts, industrial districts major transportation arteries, or other uses that are not compatible with low-density residential environment.

PRINCIPAL INTENSITY AND DIMENSIONAL STANDARDS

TYPICAL LOT PATTERN

| Minimum lot area (sf) | 4,000 (TH) 6,500 (ZLL) | |-------------------------------------------|----------------------------| | Minimum lot width (ft) | 35 (Per TH Group) 60 (ZLL) | | Minimum floor area per dwelling unit (sf) | 1,800 | | Maximum building coverage (% of lot area) | 50% | | Maximum height (ft) | 40 | | Minimum front yard depth (ft) | 20* | | Minimum side yard depth (ft) | 20 (TH) 5/10 (ZLL)** | | District land use | See section 4 | | Development standards | See section 5 | | Mobility standards | See section 6 | | Parking requirements | See section 7 | | Minimum rear yard depth (ft) | 20*** 5 for garage |

![Official zoning table, printed page 22 (PDF page 23)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/cfcce909758290fb135951a9fdb8c52a82f3a073af5f855e21c20c59e5abc6f6-zoning-table-23-11.png)

![Official zoning figure, printed page 22 (PDF page 23)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/1ecc090e739d93e924fd515a365820712b30242bd9a63b56bc76dabf88d6df58-zoning-figure-23-14.png)

NOTES: (sf = square feet, ft = feet, TH = Townhome, ZLL = Zero Lot Line

Site plan review required according to section 9.11.

*25 feet adjacent to RE, R-12, RM-8,

**15 minimum between buildings,

***10 feet adjacent to RE, R-12, RM-8,

A maximum of six dwelling units shall be allowed in each row of townhouses. Townhouse and Zero Lot Line Residential developments shall have a minimum of 10% open space.

TYPICAL DEVELOPMENT CONFIGURATION

![Official zoning figure, printed page 22 (PDF page 23)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/57aba75feb7289272d30d7f2005ea4a13cdd7589fd566ade874a9a5a0945b70f-zoning-figure-23-13.png)

3.5.8 RH SUBURBAN HIGH DENSITY RESIDENTIAL (RH)

PURPOSE

TYPICAL BUILDING TYPE

The purpose of RH Suburban High Density is to provide areas for the development of higher density of multifamily residential uses. These districts are to be located in or near the central portion of the city and other carefully selected areas where public services are adequate to support high density residential development. However, the use of this district on a smaller scale in the suburban portions of the city is appropriate as a transition area between low density residential districts and commercial districts, industrial districts, major transportation arteries or other uses not compatible with a low density residential environment.

![Official zoning figure, printed page 23 (PDF page 24)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/2b7e1756f3b0f3f0fd192baf5b776acbad8b2ea925820fc5b4ea8d1d4c70cda1-zoning-figure-24-15.png)

PRINCIPAL INTENSITY AND DIMENSIONAL STANDARDS

TYPICAL LOT PATTERN

| Minimum lot area (sf) | 8,500 (SF or TF) 43,560/5,445 per unit (MF) | |-------------------------------------------|-----------------------------------------------| | Minimum lot width (ft) | 75 | | Minimum floor area per dwelling unit (sf) | 1,400 (SF) | | Maximum building coverage (% of lot area) | 50% | | Maximum height (ft) | 40 | | Minimum front yard depth (ft) | 25 | | Minimum side yard depth (ft) | 8 (SF or TF) 20 (MF)* | | Minimum rear yard depth (ft) | 20 | | District land use | See section 4 | | Development standards | See section 5 | | Mobility standards | See section 6 | | Parking requirements | See section 7 |

![Official zoning table, printed page 23 (PDF page 24)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/aeecf0a3f8541de931bcffb85f252b9e1b7b0a94cccc1a4b83627ebce897bd1a-zoning-table-24-12.png)

![Official zoning figure, printed page 23 (PDF page 24)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/3e842a52fa069348701ec6c68b0d6b96d7d3f7d32802d27b889b46379fbd9537-zoning-figure-24-17.png)

NOTES: (sf = square feet, ft = feet, SF = single-family, TF = two-family, MF = multi-family)

Site plan review is required according to section 9.11.

*When abutting a single-family residential district

TYPICAL DEVELOPMENT CONFIGURATION

![Official zoning figure, printed page 23 (PDF page 24)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/74aef6a14ce97bcdef3964bfbcb95c22adf4da9ff417de5c94ea03fbb282aef2-zoning-figure-24-16.png)

3.5.9 MH MANUFACTURED HOME RESIDENTIAL (MH)

PURPOSE

TYPICAL BUILDING TYPE

![Official zoning figure, printed page 24 (PDF page 25)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/7ab8f895f52fcb1fbf3616fabf9fab356044c7c06a65c3071f16b8a864df49d9-zoning-figure-25-19.png)

The purpose of the MH Manufactured Home Residential District is to provide for needed and properly planned manufactured home parks. It is the intent of this ordinance that these districts may be located only in such areas as to not adversely affect the established residential subdivisions and residential densities in the city. Such locations, however, shall have necessary public services, a healthful living environment and normal amenities associated with residential zones of the city.

| PRINCIPAL INTENSITY AND DIMENSIONAL STANDARDS | PRINCIPAL INTENSITY AND DIMENSIONAL STANDARDS | |-------------------------------------------------|-------------------------------------------------| | Minimum site area (ac) | 10 | | Minimum lot size (sf) | 8,000 | | Minimum lot width (ft) | 50 | | Perimeter setback | 25 | | Minimum floor area per dwelling unit (sf) | n/a | | Maximum building coverage (% of lot area) | 50% | | Maximum height (ft) | 20 | | Minimum front yard depth (ft) | 25 | | Minimum side yard depth (ft) | 10 | | Minimum rear yard depth (ft) | 15 | | District land use | See section 4 | | Development standards | See section 5 | | Mobility standards | See section 6 | | Parking requirements | See section 7 |

![Official zoning table, printed page 24 (PDF page 25)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/6c5fdbbda5c0ee281449becb666a270376f9e1ad05261d4cd8b5fa5bc409ebd0-zoning-table-25-13.png)

TYPICAL LOT PATTERN

![Official zoning figure, printed page 24 (PDF page 25)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/f7d53813b9117db66c040ab0f3b64d2272bb1cdef9a05d41717fda3ea0a926e5-zoning-figure-25-20.png)

NOTES: (sf = square feet, ft = feet)

Site plan review is required according to section 9.11.

Height limits shall not apply to spires, cupolas, antennas, chimneys, or other mechanical appurtenances usually required to be placed above the roof level and not intended for human occupancy or to be used for any commercial or advertising purposes.

TYPICAL DEVELOPMENT CONFIGURATION

![Official zoning figure, printed page 24 (PDF page 25)](https://figures.74-208-44-221.nip.io/brandon/2026-zoning/f629992a79b4f456055f6ed58b893135a6e683842f3b75985e7201cb6f25ceea-zoning-figure-25-18.png)

Ask a question about Brandon law

Corpus searches the Brandon sections it holds and shows the ones that match, with their citations. Free, no sign-in.