§ 3.7 — Employment districts
Zoning Ordinance, City of Brandon, adopted April 6, 2026 · Brandon Zoning Regulations § 3.7
Corpus is an independent public-information project, not the official City of Brandon website. Stable reference: corpuslaw.us/code/2bdeb726-d4bf-4927-be4d-505d47dd7eeb
3.7 Employment districts.
3.7.1 OFFICE AND RESEARCH CAMPUS (ORC)
PURPOSE
TYPICAL BUILDING TYPE

These areas are intended for large-scale, office (greater than 20,000 square foot floorplates and multi stories), research and development, and light manufacturing uses (e.g. warehouses, data centers) is also appropriate for these areas. Restaurant, hotel, and business service (e.g. copy shop, computer sales and service) uses that support the office/industrial uses may be considered.
| PRINCIPAL INTENSITY AND DIMENSIONAL STANDARDS | PRINCIPAL INTENSITY AND DIMENSIONAL STANDARDS | |-------------------------------------------------|-------------------------------------------------| | Minimum lot area (sf) | 8,500 | | Minimum lot width (ft) | 75 | | Minimum floor area per dwelling unit (sf) | n/a | | Maximum building coverage (% of lot area) | 50 | | Maximum height (ft) | 90 | | Minimum front yard depth (ft) | 20 | | Minimum side yard depth (ft) | 8/25* | | Minimum rear yard depth (ft) | 15/25* | | District land use | See section 4 | | Development standards | See section 5 | | Mobility standards | See section 6 | | Parking requirements | See section 7 |

TYPICAL LOT PATTERN

Height shall not apply to industry relevant structures, any parapets including screening and rooftop utilities including condensers and air chillers to a maximum of 90 feet.
If relevant structures and appurtenances must exceed 90 feet in height, then required to increase building buffering or setbacks 1’ per 1’ of proposed height deviation. This is in addition to the standards provided in Section 5.
If industry relevant structures and appurtenances must exceed the maximum site coverage, additional buffering may be required by the Director, who shall apply the unit of measurement for a use that the Director deems most similar Site plan review required according to section 9.11.
*When abutting a Residential District.
TYPICAL DEVELOPMENT CONFIGURATION


3.7.2 LIGHT INDUSTRIAL (I-1)
PURPOSE
TYPICAL BUILDING TYPE
Light Industrial areas include light manufacturing, assembly, research and development, flex space, and large-scale office uses that do not involve hazardous materials, chemicals or processes that generate offensive levels of noise, odor, vibration or emissions. Selected business service uses are also appropriate when sized and designed to serve the employment area. Data center related facilities such as substations, fuel storage and battery storage, etc. may also be appropriate for these areas.
PRINCIPAL INTENSITY AND DIMENSIONAL STANDARDS
TYPICAL LOT PATTERN
| Minimum lot area (sf) | 30,000 | |-------------------------------------------|---------------| | Minimum lot width (ft) | 100 | | Minimum floor area per dwelling unit (sf) | n/a | | Maximum building coverage (% of lot area) | 90 | | Maximum height (ft) | 40 | | Minimum front yard depth (ft) | 40 | | Minimum side yard depth (ft) | 30/50* | | Minimum rear yard depth (ft) | 30/50* | | District land use | See section 4 | | Development standards | See section 5 | | Mobility standards | See section 6 | | Parking requirements | See section 7 |

Minimum lot area (sf)
30,000
Minimum lot width (ft)
100
Minimum floor area per dwelling unit (sf)
n/a
Maximum building coverage (% of lot area)
90
Maximum height (ft)
40
Minimum front yard depth (ft)
40
Minimum side yard depth (ft)
30/50*
Minimum rear yard depth (ft)
30/50*
District land use
See section 4
Development standards
See section 5
Mobility standards
See section 6
Parking requirements
See section 7
NOTES: (sf = square feet, ft = feet)
Height shall not apply to industry relevant structures and appurtenances to a maximum of 60 feet.
Site plan review required according to section 9.11.
*When abutting a Residential District.
TYPICAL DEVELOPMENT CONFIGURATION
3.7.3 HEAVY INDUSTRIAL (I-2)
PURPOSE
TYPICAL BUILDING TYPE

Heavy Industrial areas include all manufacturing, research and development, flex space, and may involve hazardous materials, chemicals or processes that generate offensive levels of noise, odor, vibration or emissions. Data center related facilities such as substations, fuel storage and battery storage, etc. are also appropriate for these areas. Selected business service uses are also appropriate when sized and designed to serve the employment area.
PRINCIPAL INTENSITY AND DIMENSIONAL STANDARDS
TYPICAL LOT PATTERN
| Minimum lot area (sf) | 30,000 | |-------------------------------------------|---------------| | Minimum lot width (ft) | 100 | | Minimum floor area per dwelling unit (sf) | n/a | | Maximum building coverage (% of lot area) | 90 | | Maximum height (ft) | 40 | | Minimum front yard depth (ft) | 40 | | Minimum side yard depth (ft) | 30/50* | | Minimum rear yard depth (ft) | 30/50* | | District land use | See section 4 | | Development standards | See section 5 | | Mobility standards | See section 6 | | Parking requirements | See section 7 |


NOTES: (sf = square feet, ft = feet)
Height shall not apply to industry relevant structures and appurtenances to a maximum of 60 feet.
Site plan review required according to section 9.11.
*When abutting a Residential District.
TYPICAL DEVELOPMENT CONFIGURATION