Section 504. Sanitary Sewers.

Sanitary sewer facilities shall be provided to adequately service the subdivision and conform with the City Sewer Plan. 504.1. The design criteria and parameters and standards of construction for sewer systems shall be those outlined in the latest published edition of the American Society of Civil Engineers' Manual No. 37, “Design and Construction of Storm and Sanitary Sewers” (Water Pollution Control Federation Manual No. 9). 504.2. The diameters of the sewer mains and service laterals shall not be less than those shown in the following table “Installation Minimums for Sewer Mains.” Industrial Commercial Residential Component Areas Areas Areas Collection laterals-- Mains 8" 8" 8" Service laterals 6" 6" 4" Manhole diameter 4' 4' 4' 504.3. All collection laterals, mains and system appurtenances shall be installed with a depth of cover in excess of three feet (3') in the utility strip or at other locations not under a paved surface as convenient for connection to and/or maintenance of the mains. Portions of sewers may be located under pavement if street configurations dictate, and may be located in easements outside street rights-of-way if the topography of the area so requires. Where depth of cover on a sewer is less than two and one-half feet (21/2’), the sewer shall be constructed of ductile iron pipe. 504.4. Service laterals shall be installed at the one-third point on the low side of the lot wherever practical. Service and collection laterals must be constructed prior to the construction of the base course for the street in which the lateral is installed, and plugged and extend sewer stub marker tape from pipe to ground. 504.5. Sewer systems shall be designed to the gradient and at the capability necessary to serve properties upstream of the property being developed. However, a developer will not be required to install a sewer main in a residential subdivision that exceeds ten inches (10") in diameter unless the parties being benefited thereby agree to pay the additional cost of a larger main. 504.6. Sanitary sewers shall be constructed in accordance with City of Laurel Sewage Collection Specifications. 504.7. All sewers shall be constructed to a grade that will provide a minimum velocity of two feet (2') per second when flowing full (base velocity on Mannings or Kutters formula with N = 0.013). 504.8. Manholes shall be installed at all changes in size, grade or alignment and shall have a spacing not to exceed four hundred feet (400'). 504.9. Materials. 504.9.l. Sanitary Sewer Pipe. All pipe shall be plastic or vitrified clay meeting the following specifications: (a) Plastic sewer pipe and fittings shall comply with ASTM designation D3034, “Standard Specifications for type PSM Poly (Vinyl Chloride) (PVC) Sewer Pipe and Fittings,” SDR 35. All pipe shall be SDR 35. (b) Vitrified clay sewer pipe. Standard strength vitrified clay sewer pipe and wyes, if their use is elected by the owner, shall conform and be tested and inspected in accordance with ASTM specifications, designation C-12. Extra straight sewer pipe shall conform to ASTM specifications, designation C-700. Wyes and strength bends used in service connections shall be of such degree that the connection runs perpendicularly to the main. (c) Vitrified clay pipe joints. All joints for vitrified clay pipe shall be performed ring gasket or ring type joints complying with ASTM, designations C425 or C-594 or the latest revision thereof. Gaskets shall be equal to “polytite” as manufactured by Oconee Clay Products Company, or “poly-urethane” as manufactured by W. S. Dickey Company. 504.9.2. Manholes. All manholes shall be precast concrete with twenty-four inch (24") cast iron manhole opening and cast iron steps, except where tying in to existing lines or other approved locations a brick manhole may be allowed. Manholes shall be waterproofed for water tightness. 504.10. Leakage tests. Tests for water tightness shall be made with a minimum positive head of two feet (2') by the contractor in the presence of the engineer, and the sewer shall not leak under exterior ground water pressure in excess of a rate of two hundred (200) gallons per inch of pipe diameter per mile of pipeline per twenty-four (24) hours. The tests and the measurement of infiltration shall be conducted in a manner approved by the engineer. Leaks causing any sewer to fail this test shall be repaired until the infiltration comes within the allowable limits. Any visible drip or leak shall be repaired regardless of the above leakage allowance. Where the pipe is above the water table, an exfiltration test may be required at the engineer's discretion.

Ask a question about Laurel law

Corpus searches the Laurel sections it holds and shows the ones that match, with their citations. Free, no sign-in.