Section 505. Water Lines.

505.1. Water systems shall have a sufficient number of outlets and shall be of sufficient size to furnish adequate domestic water supply, to furnish fire protection to all lots, and to conform with the City of Laurel Water Plan. 505.2. Design criteria and parameters not included herein shall be those outlined in the latest published edition of the “Recommended Standards for Water Works,” as distributed by the American Water Works Association, and/or the criteria and parameters distributed by other nationally recognized associations or institutes. 505.3. Water mains for residential areas shall be designed to supply water to each customer at a rate in excess of fifteen (15) gallons per minute (gpm) at a residual pressure of twenty (20) psi, plus the fire flow established herein. 505.4. Water mains in a fire protection grid shall be capable of delivering peak usage plus seven hundred fifty (750) gpm to each fire hydrant in a residential area and two thousand (2,000) gpm in commercial or industrial areas with a residual pressure of twenty (20) psi. 505.5. Where possible, water mains shall be located in the street right-of-way a minimum distance of two feet (2') behind the existing or proposed curb line, or as approved by the City Planning Commission or the City's engineer. 505.6. All water lines shall be cement-lined Class 150 cast iron or ductile iron based on ASA specification A-21.51, Polyvinyl Chloride (PVC) meeting A.W.W.A. C-900 standards and shall be Underwriter Laboratory (U.L.) approved, or approved equal. All pipe shall be laid in strict accordance with the manufacturer's recommended procedures. 505.7. All water lines shall be constructed with a minimum cover depth of thirty-six inches (36"). 505.8. All water mains shall be laid a minimum of ten feet (10') from sewer lines, or if they cross, within eighteen inches (18") of a sewer main. Special care shall be used for location of joints and special precautions approved by the engineer. In separations of less than eighteen inches (18"), the sewer shall be ductile iron and pressure-tested for leaks before being backfilled. 505.9. Installation of pipe, fittings, joints, trench, backfilling, thrust blocking, etc.; all procedures shall be in accordance with manufacturer's recommendations. Class D bedding as described in ASTM D-2321-74. 505.10. All fire hydrants shall be “collision type” with one (1) steamer, and two (2) two and one-half inch (21/2”) openings shall be installed at each block corner, or a maximum of eight hundred feet (800') on centers where blocks are longer than eight hundred feet (800'). A six- inch (6") gate valve and box shall be installed between the water main and each fire hydrant. 505.11. All fire hydrants shall have a valve opening with a flow equal to six-inch (6") valve opening and shall be placed on mains of not less than six inches (6") in diameter. 505.12. Gate valves shall be iron-bodied, bronze-mounted, non-rising stem, double-disc valves, designed for working pressures of not less than one hundred seventy-five (175) pounds and conforming to the standard specifications of the A.W.W.A. with “O” ring seals, and conform to Mueller No. 2280-20 or approved equal. 505.13. Service connections shall be made for each lot as indicated to behind the curb or to the property line as appropriate to minimize interference with other utilities. A bronze coupling shall be placed on the main with three-fourth inch (3/4") type K copper tubing, or high molecular weight, plastic tubing conforming to the latest ASTM standard from the main to behind the curb and terminated with a bronze curb stop of Mueller, Mark II or approved equal. The plastic tubing shall have a one hundred sixty (160) psi working pressure and bear the NSF seal. Curb stop location shall be appropriately marked with marker tape. 505.14. Testing and Chlorination. Hydrostatic test(s) shall be performed on the new water system with a pressure of one hundred fifty (150) pounds per square inch for twenty-four (24) hours. All leaks in the system shall be repaired to withstand the test to the satisfaction of the Superintendent of the Water Department of the City of Laurel. Before any part or all of the work is placed in service, the system shall be thoroughly flushed and sterilized with chlorine. Resterilize the complete parts as may be necessary until two (2) consecutive chlorine-free samples are found by the Mississippi State Board of Health to be free from the Coli-Aerogenes group of bacteria. Samples for the tests shall be taken from remote parts of the system.

Ask a question about Laurel law

Corpus searches the Laurel sections it holds and shows the ones that match, with their citations. Free, no sign-in.