For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

ELO-8 — Special Uses

Zoning Ordinance 2026, City of Madison, Mississippi; partial (Official city PDF; publication currency unverified; partial native-text extraction) · Madison Exterior Lighting § ELO-8

Corpus is an independent public-information project, not the official City of Madison website. Stable reference: corpuslaw.us/code/2079596f-06b1-4f18-bb5e-dcf5a9442a56

Section ELO-8 Special Uses

(A) Recreational Facilities. (1) Lighting for outdoor athletic fields, courts or tracks shall be exempt from the lumens limits of this Ordinance. (2) Shielding: Fully shielded lighting is required for fields designed for Class III or IV levels of play (e.g. amateur or municipal league, elementary to high school, training, recreational or social levels). Facilities designed for Class I and II levels utilize luminaries with minimal uplight consistent with the illumination constraints of the design. Where fully shielded fixtures are not utilized, acceptable luminaries shall include those which: (a) Are provided with internal and/or external glare control louvers or lenses and in stalled so as to minimize uplight and offsite light trespass and glare, and; (b) Are installed and maintained with aiming angles that permit no greater than five percent (5%) of the light emitted by each fixture to project above the horizontal. (3) Illuminance: All lighting installations shall be designed to achieve no greater than the minimal illuminance levels for the activity as recommended by the Illuminating Engineering Society of North America (IESNA RP-6) (4) Off-Site Spill: The installation shall also limit off-site spill (off the parcel containing the sports facility) to the maximum extent possible consistent with the illumination constraints of the design. For Class III and IV levels, a design goal of 5 lux (0.5fc) at any location on any non-residential property, and 1 lux (0.1fc) at any location on any residential property, as measurable from any orientation of the measuring device, shall be sought. For Class I and II levels, a design goal of 7.5 lux (0.75 fc) at any location on any non- residential property, and 1.5 lux (0.15fc) at any location on any residential property, as measurable from any orientation of the measuring device, shall be sought. (5) Certification: Every such lighting system design and installation shall be certified by a registered electrical engineer as conforming to all applicable restrictions of this Ordinance. (B) Outdoor Display Lots. (1) Lighting for display lots shall be exempt from the lumens per acre limits of this Ordinance. (2) Shielding: All display lot lighting shall utilize fully shielded luminaries that are installed in a fashion that maintains the fully shielded characteristics. (3) Display lot lighting shall be installed such that glare from the luminaire is not visible from residential properties. (4) Illuminance: the display lot shall be designed to achieve no greater than the minimal illuminance levels for the activity as recommended by the Illuminating Engineering Society of North America (IESNA Rp-33). (5) Off-Site Spill: the display lot shall limit off-site spill (off the parcel containing the display lot) to a maximum of 5 lux (0.5 fc) at any location on any non- residential property, and 0.5 lux (0.05 fc) at any location on any residential property, as measurable from any orientation of the measuring device. (6) Certification: Every display lot lighting system design and installation shall be certified by a registered electrical engineer as conforming to all applicable restrictions of this Ordinance. (7) Curfew: Display lot lighting exceeding 70,000 lumens per acre (Sec. ELO-8B) shall be turned off no later than 11:00 p.m., or within thirty minutes after closing of the business, whichever is later. Lighting in the display lot after this time shall conform to all applicable restrictions of this Ordinance, including the lumens restrictions. (C) Service Station Canopies and Parking Structures. (1) Shielding: All luminaire mounted on or recessed in the lower surface of service station canopies and Parking Structures shall be fully shielded and utilize flat lenses. (2) Total Under-Canopy Output: The total light output used for illuminating service station canopies, defined as the sum of all under-canopy initial bare- lamp outputs in lumens, shall not exceed 215 lumens per square meter (twenty lumens per square foot) not limited to luminaries mounted on the lower surface or recessed into the lower surface of the canopy, any lighting within signage or illuminated panels over the pumps, and is to be included toward the total at full initial lumen output. (3) The lumen output of lamps mounted on or within the lower surface of a canopy is included toward the lumens per acre according to the method defined in above. Other lighting located under a canopy but not mounted on or within the lower surface is included toward the lumen caps at full initial output. (4) Illuminance levels for the interior of parking structures, where interior lighting is visible from outside the structure, shall conform to the IESNA recommendations (RP-20). (D) Generally: All lighting not directly associated with the special use areas above shall conform to the lighting standards described in this Ordinance, including but not limited to the lamp type and shielding requirements and the lumens limits.

Ask a question about Madison law

Corpus searches the Madison sections it holds and shows the ones that match, with their citations. Free, no sign-in.