For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 14-78 — Specific standards

Code of Ordinances, City of Pearl, Mississippi (Supp. No. 2: codified through Ordinance of October 3, 2023) · Pearl Code of Ordinances § 14-78

Corpus is an independent public-information project, not the official City of Pearl website. Stable reference: corpuslaw.us/code/695f646b-3c75-4814-b2da-422d179e9a33

Sec. 14-78. - Specific standards.

In all areas of special flood hazards where base flood elevation data has been provided as set forth in section 14-27, the following provisions are required: (1) Residential construction. New construction or substantial improvement of any residential structure shall have the lowest floor (including basement) elevated no lower than one foot above the base flood elevation. A registered land surveyor shall certify that the standards of this subsection are satisfied. Should solid foundation perimeter walls be used to elevate a structure, openings sufficient to facilitate the unimpeded movement of floodwaters shall be provided in accordance with standards for elevated buildings. (2) Nonresidential construction. New construction or substantial improvement of any commercial, industrial or other nonresidential structure shall either have the lowest floor (including basement) no lower than one foot above the level of the base flood elevation or, together with attendant utility and sanitary facilities, be floodproofed so that below the base flood level the structure is watertight with walls substantially impermeable to the passage of water and with structural components having the capability of resisting hydrostatic and hydrodynamic loads and effects of buoyancy. A registered professional engineer or architect shall develop or review structural design, specifications, and plans for the construction and shall certify that the design and methods of construction are in accordance with accepted standards of practice. (3) Elevated buildings. New construction or substantial improvements of elevated buildings that include fully enclosed areas formed by foundation and other exterior walls below the base flood elevation shall be designed to preclude finished living space and designed to allow for the entry and exit of floodwaters to automatically equalize hydrostatic flood forces on exterior walls. a. Designs for complying with this requirement must either be certified by a professional engineer or architect or meet the following minimum criteria: 1. Provide a minimum of two openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding; 2. The bottom of all openings shall be no higher than one foot above grade; and 3. Openings may be equipped with screens, louvers, valves or other coverings or devices provided they permit the automatic flow of floodwaters in both directions. b. Electrical, plumbing, and other utility connections are prohibited below the base flood elevation, unless they are designed so as to prevent water from entering or accumulating within equipment components (floodproofed); c. Access to the enclosed area is the minimum necessary to allow for parking of vehicles (garage door) or limited storage of maintenance equipment used in connection with the premises (standard exterior door) or entry to the living area (stairway or elevator); and d. The interior portion of the enclosed area shall not be partitioned or finished into separate rooms. (4) Manufactured homes. a. All manufactured homes to be placed or substantially improved within zones A1 through A30, and AH shall be elevated on a permanent foundation that: 1. The lowest floor of the manufactured home is at least one foot above the base flood elevation and is securely anchored to an adequately anchored foundation; or 2. The manufactured home chassis shall be supported by reinforced piers or other foundation elements of at least an equivalent strength, of no less than 36 inches in height above grade. In existing manufactured home parks where a manufactured home is moved out and another is moved in, the community development department may certify as to the elevation above the base flood elevation or the above grade elevation. b. All manufactured homes shall be anchored to resist flotation, collapse, or lateral movement by providing over-the-top and frame ties to ground anchors as specified in MCA 1972, § 19-7-5.04. Specific minimum requirements shall be that: 1. Over-the-top ties be provided at each of the four corners of the manufactured home, with two additional ties per side at intermediate locations and manufactured homes less than 50 feet long requiring one additional tie per side; 2. Frame ties be provided at each corner of the home with five additional ties per side at intermediate points and manufactured homes less than 50 feet long require four additional ties per side; 3. All components of the anchoring system be capable of carrying a force of 4,800 pounds; and 4. Any additions to the manufactured home be similarly anchored. c. New manufactured home parks and subdivisions, expansions to existing manufactured home parks and subdivisions, existing manufactured home parks and subdivisions, and mobile homes not placed in a mobile home park or subdivision require: 1. Stands or lots are elevated on compacted fill or on pilings so that the lowest floor of the manufactured home will be one foot above the base flood level; 2. Adequate surface drainage and access for a hauler are provided; and 3. In the instance of elevation on pilings: (i) Lots are large enough to permit steps; (ii) Piling foundations are placed in stable soil no more than ten feet apart; (iii) Reinforcement is provided for pilings more than six feet above the ground level. 4. In an existing manufactured home park or subdivision on which a manufactured home has incurred substantial damage as the result of a flood, any manufactured home placed or substantially improved must meet the standards of subsection (4)a.1 and 2 of this section. d. All recreational vehicles placed on sites must either: 1. Be fully licensed and ready for highway use; or 2. The recreational vehicle must meet all the requirements for new construction, including anchoring and elevation requirements of subsection (4)a.1 and 2 of this section. A recreational vehicle is ready for highway use if it is on its wheels or jacking system, is attached to the site only by quick-disconnect type utilities and security devices and has no permanently attached structures. (5) Floodways. Located within areas of special flood hazard established in section 14-27 are areas designated as floodways. Since the floodway is an extremely hazardous area due to the velocity of floodwaters which carry debris, potential projectiles and erosion potential, the following provisions shall apply: a. Encroachment of roads and bridges, new construction, substantial improvements and other development is prohibited unless certification by a professional registered engineer or architect is provided demonstrating that encroachments shall not result in any increase in flood levels during occurrence of the base flood discharge. b. If the above certification is approved by the local administrator, all new construction and substantial improvements shall comply with all applicable flood hazard reduction provisions of this article.

(Code 1974, § 8½-27; Ord. No. 1990-203, art. 5, § B, 2-20-1990)

Ask a question about Pearl law

Corpus searches the Pearl sections it holds and shows the ones that match, with their citations. Free, no sign-in.