§ 38.400.090 — Access
Bozeman Municipal Code, City of Bozeman, Montana (Codified through Order No. 2026-11, adopted September 15, 2026. (Supp. No. 16, Update 1)) · Bozeman Municipal Code § 38.400.090
Corpus is an independent public-information project, not the official City of Bozeman website. Stable reference: corpuslaw.us/code/387c8fc9-88fd-4dab-a8d9-2a31b1a1adae
Sec. 38.400.090. - Access.
A. General. All final site plans and plats must contain a statement requiring lot accesses to be built to the standard contained in this section, the City of Bozeman Design and Construction Standards, and the City of Bozeman Modifications to Montana Public Works Standard Specifications. 1. Lot access standards. The drive approach must be constructed in accordance with the city's standard approach, which includes a concrete apron, sidewalk section and drop-curb. 2. A city curb cut and sidewalk permit must be obtained from the engineering department prior to installation of the approach. 3. Access must comply with any city-adopted International Fire Code. B. Drive access from improved public street, approved private street or alley required. 1. For purposes of this Code, "improved" public street, approved private street, or alley means and includes any street or alley within the city constructed to a standard which meets or exceeds standards established by this chapter, the City of Bozeman Design and Construction Standards, and the City of Bozeman Modifications to Montana Public Works Standard Specifications. Constructed public streets which may not meet current city standards but which are constructed to a standard that has historically provided an adequate level of service to adjacent properties, which level of service would not be degraded as a result of a pending development proposal. 2. Unless otherwise allowed by this chapter, all lots must be provided with legal and physical access via one of the following options: a. Fifteen feet of frontage on a public or approved private street; b. Fifteen feet of frontage on a public or approved private street and an improved alley; or c. Fifteen feet of frontage on an improved alley and a greenway corridor or trail corridor which includes a transportation pathway meeting sidewalk or shared use path standards of 38.400.110 with public access. Access to each home from the transportation pathway must be provided. Developer must make provision for all necessary maintenance to keep the transportation pathway accessible and functional year round. This option may require additional improvements to the alley to accommodate emergency access, snow removal and storage, and the provision of utilities. The alley may also require signage for the provision of emergency services. d. Have a courtyard access meeting standards of 38.410.030.D. C. Drive access requirements. 1. Drive accesses are required for commercial parking lots and parking lots for residential developments subject to the site plan review procedures of 38.740. 2. Parking areas for residential developments subject to the sketch plan review procedures of 38.740.060, may take access directly from an improved public street, approved private street or improved alley as defined in subsection B.1 of this section with access provided according to the provisions of this section and 38.530.020.C. 3. All drive accesses installed, altered, changed, replaced or extended must comply with the following requirements: a. Residential. (1) Residential lots must not have direct access to arterials or collectors, unless the standards contained in Table 38.400.090-1 are complied with; (2) Residential drive access standards apply to all residential development with drive access facing a street, except apartment buildings. (a) Individual residential drive accesses facing the street with a single internal parking bay meeting the standard of Table 38.530.020-1 may not exceed 12 feet in width measured at the right-of-way line and 18 feet in width measured at the curb line. (b) Individual residential drive accesses facing the street with two or more internal parking bays meeting the standard of Table 38.530.020-1 may not exceed 20 feet in width measured at the right-of-way line and 26 feet in width measured at the curb line. (c) Individual and shared drive accesses must be physically separated by means of a landscaped area greater than or equal to 10 feet in width between paved areas and extending from the front line of the building to the right-of-way line. (d) Residential complexes with 25 or more dwelling units must meet the commercial access standards in subsection b. below. b. Non-residential. (1) Commercial drive access widths must be no greater than 35 feet measured at the inside edge of the drive access extended, at its intersection with the projected curbline of the intersecting street. Two-way drive access must be a minimum of 24 feet and one-way drive access must be a minimum of 16 feet. (2) Industrial drive access widths must be no greater than 40 feet measured at the inside edge of the drive access extended, at its intersection with the projected curbline of the intersecting street. Two-way drive accesses must be a minimum of 24 feet and one-way drive accesses must be a minimum of 16 feet. [image omitted; see the official code] Figure 38.400.090-1. Commercial and industrial accesses. c. Drive accesses for all multiple tenant commercial buildings or complexes/centers, or industrial drive accesses must be set back a minimum of 20 feet from the adjacent property line unless such drive access is approved as a shared drive access. d. Drive accesses to drive-in theaters, stadiums, racetracks, funeral homes or uses generating very heavy periodic traffic conflicts must be located not closer than 200 feet to any pedestrian or vehicular entrance or exit to a school, college, university, church, hospital, public emergency shelter or other place of public assembly. e. All commercial and industrial drive accesses on arterial streets must have a radii in accordance with the city's design and construction standards, unless otherwise approved by the review authority. All commercial and industrial drive accesses on other streets may have either return radii or depressed curbs. D. Spacing standards for drive accesses. 1. General. a. Consolidation of access points onto public streets, to achieve a distance between access points in excess of the minimum standards in this section, is desired and must be considered during all levels of site plan review. b. For the purposes of this section, public or private access means any street, alley, driveway or other point of vehicular access to a publicly controlled street. c. The distance between public and/or private accesses on a public street must be measured between the right-of-way line for public accesses and the nearest inside edges of private accesses according to the following distances specified in Table 38.400.090-1. d. This subsection D does not apply to single-, two-, three-, or four-unit dwellings on individual lots. [image omitted; see the official code] Figure 38.400.090-2. Spacing standards for drive accesses. 2. The standards in Table 38.400.090-1 apply to the minimum distance between public and/or private accesses and intersections, and the minimum distance between public and/or private accesses and other public and/or private accesses. a. Partial access excludes left turns onto the major street. b. Full access allows all turn movements, in and out. Table 38.400.090-1.\Minimum distance between public/private accesses, local streets, and intersections. Access Located on Principal Arterial Streets | Access Located on Minor Arterial and Collector Streets | Access Located on Local Streets Average Spacing | In All Districts | In All Districts | In All Districts Partial access | 315' | 150' | 40' Full access | 660' | 330' | 40' Minimum separation | 315' | 150' | 40' E. Number and location of drive accesses. 1. Single-household uses are limited to one drive access per street face, except on properties abutting arterial streets, in which case shared accesses, or drive aisles facilitating the turning of automobiles on-site are required. 2. Notwithstanding any other provisions of this chapter, drive accesses may not be located closer than five feet to any side property line, unless shared access, as defined in 38.800.200, with the adjoining property is approved. This standard does not apply to the shared side property line of townhouses units with adjacent garages using attached drive aisles. F. Shared drive access. The city desires and encourages sharing access drives, as defined in 38.800.200, between separate parcels. G. Access approval required. All drive accesses may be approved by the review authority for width and location. H. Modifications of property access standards. 1. Some of the standards listed in subsections C through E of this section, may be relaxed by the review authority if it is shown during the development review process that more efficient design can be accomplished without jeopardizing the public's health, safety and welfare, the purpose of this chapter, or the purpose of the city's land use plan. 2. Modifications from access standards may be approved by the review authority. 3. Commercial developments (including residential complexes for five or more households) which may not be able to meet the requirements of subsections C through E of this section, and are requesting modifications from the standards, must submit to the city engineer a report certified by a professional engineer addressing the following site conditions, both present and future: a. Traffic volumes; b. Turning movements; c. Traffic controls; d. Site design; e. Sight distances; and f. Location and alignment of other access points. 4. Based upon the above data, the review authority will determine whether a modification from the required standards is justified and, if so, what alternative requirements will be necessary.
(Ord. No. 2025-12, § 4(Exh. A), 12-16-2025)
Ask a question about Bozeman law
Corpus searches the Bozeman sections it holds and shows the ones that match, with their citations. Free, no sign-in.
